Contents
2024
Volume: 43 Issue 1
18 Article(s)

Export citation format
Research Articles
Study on material characterization and device performance of non-uniform GaAs/AlGaAs quantum well infrared detectors
Jia-Ping SU, Xiao-Hao ZHOU, Zhou TANG, Liu-Yan FAN, Shun-Ji XIA, Ping-Ping CHEN, and Ze-Zhong CHEN
In this paper, the GaAs/AlGaAs non-uniform quantum well infrared detector material was successfully grown by molecular beam epitaxy (MBE), and the microstructure was characterized in detail. The performance difference between the non-uniform quantum well structure and the conventional quantum well infrared detector is
Journal of Infrared and Millimeter Waves
  • Publication Date: Feb. 25, 2024
  • Vol. 43, Issue 1, 7 (2024)
Si Ion Implantation Study of InAs/GaSb Type II superlattice Materials
Miao He, Yi Zhou, Xiang-Xiao Ying, Zhao-Min Liang, Min Huang, Zhi-Fang Wang, Yi-Hong Zhu, Ke-Cai Liao, Nan Wang, and Jian-Xin Chen
Class II superlattice infrared detectors generally detect infrared radiation through mesa junction, while transverse PN junction is realized through ion implantation. On the one hand, the material epitaxy process is simple, and at the same time, the advantages of superlattice material that the transverse diffusion leng
Journal of Infrared and Millimeter Waves
  • Publication Date: Feb. 25, 2024
  • Vol. 43, Issue 1, 15 (2024)
Study on HgCdTe detectors with high operating temperature by junction formation simulator
Jia-Mu LIN, Song-Min ZHOU, Xi WANG, Zhi-Kai GAN, Chun LIN, and Rui-Jun DING
Journal of Infrared and Millimeter Waves
  • Publication Date: Feb. 25, 2024
  • Vol. 43, Issue 1, 23 (2024)
Effect of different growth conditions on surface morphology and optical properties of CdTe/GaAs epitaxial films
Chen-Wei ZHU, Xin-Yang LIU, Yan WU, Xin-Rong ZUO, Liu-Yan FAN, Ping-Ping CHEN, and Xiao-Mei QIN
CdTe(211)thin films are grown on GaAs(211)B substrates by molecular beam epitaxy(MBE), the influence of different process conditions on the surface morphology and optical properties of the CdTe epitaxial films are stematically studied. The study shows that under certain growth temperatures, growing CdTe thin films in a
Journal of Infrared and Millimeter Waves
  • Publication Date: Feb. 25, 2024
  • Vol. 43, Issue 1, 29 (2024)
Improved detection performance of 1280 × 1024 middle-wavelength infrared HgCdTe focal plane arrays with 10 μm pixel pitch
Bi-Song TAN, Jian-Hong MAO, Shu-Xuan CHEN, Wei-Wei LI, Shi-Rui CHEN, Tian-Qing CHEN, Yu DU, Chen-Pan PENG, Xiong XIONG, Yong-Qiang ZHOU, Bo YU, and Shu WANG
In this paper, an investigation into the preparation technology and performance of 1280×1024 middle-wavelength (MW) HgCdTe infrared focal plane arrays (IRFPAs) with a pixel size of 10μm was introduced. The manufacturing process of these high-resolution FPAs involved the utilization of B+ injection to establish sma
Journal of Infrared and Millimeter Waves
  • Publication Date: Feb. 25, 2024
  • Vol. 43, Issue 1, 36 (2024)
Recent advances in on-chip infrared polarization detection
Yu-Ran ZHEN, Jie DENG, Yong-Hao BU, Xu DAI, Yu YU, Meng-Die SHI, Ruo-Wen WANG, Tao YE, Gang CHEN, and Jing ZHOU
Journal of Infrared and Millimeter Waves
  • Publication Date: Feb. 25, 2024
  • Vol. 43, Issue 1, 52 (2024)
Correlation between MBE deoxidation conditions and InGaAs/InP APD performance
Zi-Lu GUO, Wen-Juan WANG, Hui-Dan QU, Liu--Yan FAN, Yi-Cheng ZHU, Ya-Jie WANG, Chang-Lin ZHENG, Xing-Jun WANG, Ping-Ping CHEN, and Wei LU
InP-based InGaAs/InP avalanche photodiodes (APDs) have high sensitivity to near-infrared light, making them ideal optoelectronic devices for weak signal and single-photon detection. However, as device structures become complex and advanced, with thickness and sizes ranging from quantum dots to several micrometers, perf
Journal of Infrared and Millimeter Waves
  • Publication Date: Feb. 25, 2024
  • Vol. 43, Issue 1, 63 (2024)
High responsivity Terahertz detector linear array based on CMOS
Xue BAI, Zi-Yu ZHANG, Lei-Jun XU, Xin-Ke ZHAO, and Xiao-Long FAN
This paper presents an improved 0.18 μm CMOS detector linear array with high voltage responsiveness. Each pixel consists of high-gain on-chip antenna, high-coupling self-mixing power detection circuit and integrated voltage amplifier. The differential detection circuit uses the cross-coupling capacitance of the source
Journal of Infrared and Millimeter Waves
  • Publication Date: Feb. 25, 2024
  • Vol. 43, Issue 1, 70 (2024)
Nonlinear response correction method for on-orbit data of FY-3E hyperspectral infrared atmospheric sounder II
Shuo HUANG, Ming-Jian GU, Yong HU, Tian-Hang YANG, Chun-Yuan SHAO, and Chun-Ming ZHANG
The Infrared Hyperspectral Atmospheric Sounder II (HIRAS-II) mounted on Funyun-3E satellite (FY-3E) can realize vertical atmospheric detection, featuring hyper spectral, high sensitivity and high precision. When the satellite has been on-orbit, nonlinear response would occur due to instrument attenuation and environmen
Journal of Infrared and Millimeter Waves
  • Publication Date: Feb. 25, 2024
  • Vol. 43, Issue 1, 98 (2024)
Infrared small target detection based on associated directional gradient and mean contrast
Ning LI, Yi-Fang GUO, Ji-Chao JIAO, Min PANG, and Wei XU
The detection of infrared small targets has been a challenging task in the field of computer vision due to the low percentage of small targets in the whole image and the presence of a large amount of clutter around the targets. We propose an algorithm based on associated directional gradient and mean contrast. The algo
Journal of Infrared and Millimeter Waves
  • Publication Date: Feb. 25, 2024
  • Vol. 43, Issue 1, 106 (2024)
Research on the stress defect detection of infrared material using differential frequency modulation with cascaded dual photoelastic modulators
Ke-Wu LI, Shuang WANG, Meng-Wei LI, and Zhi-Bin WANG
Journal of Infrared and Millimeter Waves
  • Publication Date: Feb. 25, 2024
  • Vol. 43, Issue 1, 126 (2024)
Near-infrared monocular vision measurement and reference image self-healing of object random rough surface
Wang HOU, Ye-Pin QU, Jian-Qiang LIU, and Yu-Hai LYU
In response to the special situation where the near-infrared monocular vision pose measurement system in complex application environments deviates from the preset cooperative target object and cannot complete pose measurement, a monocular vision measurement method based on the random rough surface image around the coop
Journal of Infrared and Millimeter Waves
  • Publication Date: Feb. 25, 2024
  • Vol. 43, Issue 1, 134 (2024)