• Acta Optica Sinica
  • Vol. 40, Issue 3, 0326001 (2020)
Haiyu Li1, Chao Li2, Xiaobo Li1, Hui Wang3, Haofeng Hu1、*, and Tiegen Liu1
Author Affiliations
  • 1Key Laboratory of Opto-electronics Information Technology, Ministry of Education, School of Precision Instrument & Opto-electronics Engineering, Tianjin University, Tianjin 300072, China;
  • 2Institute of Medical Support Technology, Institute of System Engineering, Academy of Military Sciences, Tianjin 300160, China
  • 3College of Physics Science and Information Engineering, Hebei Normal University, Shijiazhuang, Hebei 0 50024, China
  • show less
    DOI: 10.3788/AOS202040.0326001 Cite this Article Set citation alerts
    Haiyu Li, Chao Li, Xiaobo Li, Hui Wang, Haofeng Hu, Tiegen Liu. Optimization of Polarization-Camera-Based Full Stokes Polarimeter[J]. Acta Optica Sinica, 2020, 40(3): 0326001 Copy Citation Text show less
    References

    [1] Liao Y B[M]. Polarization of optics(2003).

    [2] Goldstein D[M]. Polarized light, revised and expanded(2003).

    [3] Li X B, Hu H F, Zhao L et al. Polarimetric image recovery method combining histogram stretching for underwater imaging[J]. Scientific Reports, 8, 12430(2018). http://www.ncbi.nlm.nih.gov/pubmed/30127366

    [4] Liang J, Ju H J, Zhang W F et al. Review of optical polarimetric dehazing technique[J]. Acta Optica Sinica, 37, 0400001(2017).

    [5] Hu H F, Li X B, Liu T G. Recent advances in underwater image restoration technique based on polarimetric imaging[J]. Infrared and Laser Engineering, 48, 0603006(2019).

    [6] Morimoto A, Matsunaga S, Kurihara D et al. Visualization of mitotic HeLa cells by advanced polarized light microscopy[J]. Micron, 39, 635-638(2008).

    [7] Tyo J S, Goldstein D L, Chenault D B et al. Review of passive imaging polarimetry for remote sensing applications[J]. Applied Optics, 45, 5453-5469(2006).

    [8] Kanseri B, Rath S, Kandpal H C. Direct determination of the generalized Stokes parameters from the usual Stokes parameters[J]. Optics Letters, 34, 719-721(2009).

    [9] Berry H G, Gabrielse G, Livingston A E. Measurement of the Stokes parameters of light[J]. Applied Optics, 16, 3200-3205(1977).

    [10] Kihara T. Measurement method of Stokes parameters using a quarter-wave plate with phase difference errors[J]. Applied Optics, 50, 2582-2587(2011).

    [11] Wang Y H, Zheng C L, Zhao Z T. Multi-point calibration method based on Stokes ellipsometry system[J]. Chinese Journal of Lasers, 39, 1108013(2012).

    [12] Du X L, Dai J M. Review of division-of-amplitude photo polarimeter[J]. Acta Metrologica Sinica, 27, 325-330(2006).

    [13] Tyo J S. LaCasse C F, Ratliff B M. Total elimination of sampling errors in polarization imagery obtained with integrated microgrid polarimeters[J]. Optics Letters, 34, 3187-3189(2009).

    [14] He H C. Study on optical system of simultaneous and complete polarization imaging[D]. Suzhou: Soochow University, 17-42(2014).

    [15] Zhang Z G, Dong F L, Zhang Q C et al. Fabrication of pixelated polarizer array and its application in polarization enhancement[J]. Acta Physica Sinica, 63, 184204(2014).

    [16] Gruev V, Perkins R, York T. Material detection with a CCD polarization imager. [C]//2010 IEEE 39th Applied Imagery Pattern Recognition Workshop (AIPR), October 13-15, 2010, Washington, DC, USA. New York: IEEE, 11973151(2010).

    [17] Qi J, He C, Elson D S. Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging[J]. Biomedical Optics Express, 8, 4933-4946(2017).

    [18] Goudail F. Equalized estimation of Stokes parameters in the presence of Poisson noise for any number of polarization analysis states[J]. Optics Letters, 41, 5772-5775(2016).

    [19] Foreman M R, Favaro A, Aiello A. Optimal frames for polarization state reconstruction[J]. Physical Review Letters, 115, 263901(2015).

    [20] Shibata S, Hagen N, Otani Y. Robust full Stokes imaging polarimeter with dynamic calibration[J]. Optics Letters, 44, 891-894(2019).

    [21] Li X B, Goudail F, Hu H F et al. Optimal ellipsometric parameter measurement strategies based on four intensity measurements in presence of additive Gaussian and Poisson noise[J]. Optics Express, 26, 34529-34546(2018).

    [22] Li X B, Hu H F, Wu L et al. Optimization of instrument matrix for Mueller matrix ellipsometry based on partial elements analysis of the Mueller matrix[J]. Optics Express, 25, 18872-18884(2017).

    [23] Duan Q Y, Gupta V K, Sorooshian S. Shuffled complex evolution approach for effective and efficient global minimization[J]. Journal of Optimization Theory and Applications, 76, 501-521(1993).

    [24] Perez J J G, Ossikovski R. Polarized light and the Mueller matrix approach[M]. Boca Raton: CRC press(2017).

    Haiyu Li, Chao Li, Xiaobo Li, Hui Wang, Haofeng Hu, Tiegen Liu. Optimization of Polarization-Camera-Based Full Stokes Polarimeter[J]. Acta Optica Sinica, 2020, 40(3): 0326001
    Download Citation