• Spectroscopy and Spectral Analysis
  • Vol. 41, Issue 1, 312 (2021)
Qi-xing TANG1、1、*, Yi ZHOU1、1, Pang-da DAI1、1, Yan-wei GAO1、1, Bo-qiang FAN1、1, Meng-qi LI1、1, Ying HE1、1, Kun YOU1、1, and Yu-jun ZHANG1、1
Author Affiliations
  • 1[in Chinese]
  • 11. Key Laboratory of Environmental Optics & Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
  • show less
    DOI: 10.3964/j.issn.1000-0593(2021)01-0312-07 Cite this Article
    Qi-xing TANG, Yi ZHOU, Pang-da DAI, Yan-wei GAO, Bo-qiang FAN, Meng-qi LI, Ying HE, Kun YOU, Yu-jun ZHANG. Research on Constant Temperature Two-Color Light Sources for Nighttime Visibility Estimation[J]. Spectroscopy and Spectral Analysis, 2021, 41(1): 312 Copy Citation Text show less
    The diagram of the dual light sources visibility measurement methodThe black block is bold
    Fig. 1. The diagram of the dual light sources visibility measurement method
    The black block is bold
    The relationship between wavelength and transmittanceThe visibility is 40, 50, 60
    Fig. 2. The relationship between wavelength and transmittance
    The visibility is 40, 50, 60
    The structure diagram of the visibility observation system based on the constant temperature two-color light sourcesThe light source 1 and 2 are respectively separated from the cameras L1 and L2 (L1>L2)
    Fig. 3. The structure diagram of the visibility observation system based on the constant temperature two-color light sources
    The light source 1 and 2 are respectively separated from the cameras L1 and L2 (L1>L2)
    The light intensity measurement results of dual light sources. The inset: zoom in the partial image
    Fig. 4. The light intensity measurement results of dual light sources. The inset: zoom in the partial image
    Visibility measurement results when the dual light sources are red lightL1 is 20 m, L2 is 50 m
    Fig. 5. Visibility measurement results when the dual light sources are red light
    L1 is 20 m, L2 is 50 m
    Visibility measurement results when the dual light sources are blue light
    Fig. 6. Visibility measurement results when the dual light sources are blue light
    Visibility measurement results of dual light sources method
    Fig. 7. Visibility measurement results of dual light sources method
    Visibility measurement results on a rainy day
    Fig. 8. Visibility measurement results on a rainy day
    Visibility measurement results in the foggy day
    Fig. 9. Visibility measurement results in the foggy day
    Visibility measurement results on a sunny day The inset: zoom in the partial image
    Fig. 10. Visibility measurement results on a sunny day The inset: zoom in the partial image
    Visibility/mMethod one:
    error/%
    Method one:
    error/%
    0~5 0002.165.44
    5 000~10 0006.2910.31
    10 000~15 0004.018.64
    Table 1. The statistical errors
    Qi-xing TANG, Yi ZHOU, Pang-da DAI, Yan-wei GAO, Bo-qiang FAN, Meng-qi LI, Ying HE, Kun YOU, Yu-jun ZHANG. Research on Constant Temperature Two-Color Light Sources for Nighttime Visibility Estimation[J]. Spectroscopy and Spectral Analysis, 2021, 41(1): 312
    Download Citation