• Journal of Infrared and Millimeter Waves
  • Vol. 41, Issue 2, 430 (2022)
Ke-Jing CAO, Ao ZHANG, and Jian-Jun GAO*
Author Affiliations
  • School of Physics and Electronic Sciences,East China Normal University,Shanghai 200241,China
  • show less
    DOI: 10.11972/j.issn.1001-9014.2022.02.008 Cite this Article
    Ke-Jing CAO, Ao ZHANG, Jian-Jun GAO. Accuracy estimation of microwave performance for InP HBTs based on Monte-Carlo analysis[J]. Journal of Infrared and Millimeter Waves, 2022, 41(2): 430 Copy Citation Text show less
    The intrinsic part of π-topology small-signal equivalent circuit model of HBT devices
    Fig. 1. The intrinsic part of π-topology small-signal equivalent circuit model of HBT devices
    Estimated relative uncertainty of intrinsic parameters Cπ versus frequency
    Fig. 2. Estimated relative uncertainty of intrinsic parameters Cπ versus frequency
    Magnitude accuracy of S-parameters(45MHz∼40GHz)
    Fig. 3. Magnitude accuracy of S-parameters(45MHz∼40GHz)
    Positive and negative deviation rates of S-parameters(45 MHz∼40 GHz)
    Fig. 4. Positive and negative deviation rates of S-parameters(45 MHz∼40 GHz)
    H21 versus frequency and accuracy range of current gain cutoff frequency
    Fig. 5. H21 versus frequency and accuracy range of current gain cutoff frequency
    U andMSG/MAG versus frequency with uncertainty
    Fig. 6. U andMSG/MAG versus frequency with uncertainty
    ParameterIb=40 μAIb=60 μAIb=80 μA
    Valueσmin(%)Valueσmin(%)Valueσmin(%)
    Cμ/fF7.6009.1577.5507.8687.5008.047
    Cπ/pF0.1758.9240.2029.1610.2489.620
    Rπ730.022.97506.015.28375.014.49
    gm0/S0.0658.9000.1028.7200.1418.643
    τπ/ps0.050121.40.100107.80.12101.9
    Table 1. Values and minimum uncertainties of intrinsic parameters
    BiasIb=40 μAIb=60 μAIb=80 μA
    ValueAccuracyValueAccuracyValueAccuracy
    fT60(45,71)68(53,88)87(66,100)
    fMAXU31(23,40)43(30,52)50(36,70)
    fMAX(MSG/MAG)32(31,40)46(40,52)53(45,63)
    Table 2. Values and accuracy range of fT and fMAX at three bias points