• Acta Optica Sinica
  • Vol. 41, Issue 6, 0611003 (2021)
Lei Li1、2, Chuandong Tan1、2, Mingjuan Liao2、3, Haijun Yu2、3, Yarui Xi2、3, and Fenglin Liu1、2、3、*
Author Affiliations
  • 1State Key Laboratory of Mechanical Transmissions, Chongqing University, Chongqing 400044, China
  • 2Engineering Research Center of Industrial Computed Tomography Nondestructive Testing, Ministry of Education, Chongqing University, Chongqing 400044, China
  • 3Key Laboratory of Optoelectronic Technology & Systems (Chongqing University), Ministry of Education, Chongqing 400044, China;
  • show less
    DOI: 10.3788/AOS202141.0611003 Cite this Article Set citation alerts
    Lei Li, Chuandong Tan, Mingjuan Liao, Haijun Yu, Yarui Xi, Fenglin Liu. Analytic Reconstruction for Parallel Translational Computed Tomography Based on Radon Inverse Transform[J]. Acta Optica Sinica, 2021, 41(6): 0611003 Copy Citation Text show less
    References

    [1] du Plessis A, le Roux S G, Guelpa A. Comparison of medical and industrial X-ray computed tomography for non-destructive testing[J]. Case Studies in Nondestructive Testing and Evaluation, 6, 17-25(2016). http://www.sciencedirect.com/science/article/pii/S2214657116300302

    [2] Cai Y F, Chen T Y, Wang J et al. Image noise reduction in computed tomography with non-local means algorithm based on adaptive filtering coefficients[J]. Acta Optica Sinica, 40, 0710001(2020).

    [3] Liu J, Kang Y Q, Gu Y B et al. Low dose computed tomography image reconstruction based on sparse tensor constraint[J]. Acta Optica Sinica, 39, 0811004(2019).

    [4] Liu F, Yu H, Cong W et al. Top-level design and pilot analysis of low-end CT scanners based on linear scanning for developing countries[J]. Journal of X-ray Science and Technology, 22, 673-686(2014). http://europepmc.org/abstract/MED/25265926

    [5] de Schryver T, Dhaene J, Dierick M et al. In-line NDT with X-ray CT combining sample rotation and translation[J]. NDT & E International, 84, 89-98(2016).

    [6] Liu B, Luo Y, Li K et al. X-ray layered refocusing imaging based on linear scanning[J]. IEEE Photonics Journal, 12, 1-12(2020). http://ieeexplore.ieee.org/document/9104904

    [7] Zhang T, Xing Y X, Zhang L et al. Stationary computed tomography with source and detector in linear symmetric geometry: direct filtered backprojection reconstruction[J]. Medical Physics, 47, 2222-2236(2020). http://onlinelibrary.wiley.com/doi/abs/10.1002/mp.14058

    [8] Wang C X, Zeng L, Yu W et al. An electron beam linear scanning mode for industrial limited-angle nano-computed tomography[J]. The Review of Scientific Instruments, 89, 015113(2018). http://adsabs.harvard.edu/abs/2018RScI...89a5113W

    [9] Luo T, Zhao Y S. An acceleration algorithm for dual-spectral computed tomography reconstruction[J]. Acta Optica Sinica, 40, 1411001(2020).

    [10] Wu W W, Quan C, Liu F L. Filtered back-projection image reconstruction algorithm for opposite parallel linear CT scanning[J]. Acta Optica Sinica, 36, 0911009(2016).

    [11] Kong H H, Yu H Y. Analytic reconstruction approach for parallel translational computed tomography[J]. Journal of X-Ray Science and Technology, 23, 213-228(2015). http://www.ncbi.nlm.nih.gov/pubmed/25882732

    [12] Wu W W, Yu H Y, Wang S Y et al. BPF-type region-of-interest reconstruction for parallel translational computed tomography[J]. Journal of X-Ray Science and Technology, 25, 487-504(2017). http://dx.doi.org/10.3233/xst-16208

    [13] Wu W W, Yu H Y, Cong W X et al. Theoretically exact backprojection filtration algorithm for multi-segment linear trajectory[J]. Physics in Medicine and Biology, 63, 015037(2018). http://europepmc.org/abstract/MED/29053104

    [14] Qiao Z W, Han Y, Wei X Y. Acceleration method of the filtered back projection algorithm[J]. Systems Engineering and Electronics, 32, 401-404(2010).

    [15] Shi H L, Luo S Q. A novel scheme to design the filter for CT reconstruction using FBP algorithm[J]. BioMedical Engineering OnLine, 12, 1-15(2013). http://www.ncbi.nlm.nih.gov/pubmed/23724942

    [16] Zeng G L. Nonuniform noise propagation by using the ramp filter in fan-beam computed tomography[J]. IEEE Transactions on Medical Imaging, 23, 690-695(2004). http://ieeexplore.ieee.org/xpls/icp.jsp?arnumber=1302207

    [17] You J S, Zeng G L. Hilbert transform based FBP algorithm for fan-beam CT full and partial scans[J]. IEEE Transactions on Medical Imaging, 26, 190-199(2007). http://www.ncbi.nlm.nih.gov/pubmed/17304733

    [18] Noo F, Defrise M, Clackdoyle R et al. Image reconstruction from fan-beam projections on less than a short scan[J]. Physics in Medicine and Biology, 47, 2525-2546(2002). http://www.ncbi.nlm.nih.gov/pubmed/12171338

    [19] Noo F, Clackdoyle R, Pack J D. A two-step Hilbert transform method for 2D image reconstruction[J]. Physics in Medicine and Biology, 49, 3903-3923(2004). http://www.ncbi.nlm.nih.gov/pubmed/15470913

    [20] Ma C X, Hu J J, Yan B. Optimization of fan-beam CT filtered backprojection reconstruction algorithm[J]. Laser & Optoelectronics Progress, 49, 091103(2012).

    [21] Gregor J, Benson T. Computational analysis and improvement of SIRT[J]. IEEE Transactions on Medical Imaging, 27, 918-924(2008). http://www.ncbi.nlm.nih.gov/pubmed/18599397

    [22] Defrise M, Noo F, Clackdoyle R et al. Truncated Hilbert transform and image reconstruction from limited tomographic data[J]. Inverse Problems, 22, 1037-1053(2006). http://adsabs.harvard.edu/abs/2006invpr..22.1037d

    [23] Chen M, Zhang H T, Zhang P. BPF-based reconstruction algorithm for multiple rotation-translation scan mode[J]. Progress in Natural Science, 18, 209-216(2008).

    [24] Zeng G L. Image reconstruction via the finite Hilbert transform of the derivative of the backprojection[J]. Medical Physics, 34, 2837-2843(2007). http://onlinelibrary.wiley.com/doi/10.1118/1.2739813

    Lei Li, Chuandong Tan, Mingjuan Liao, Haijun Yu, Yarui Xi, Fenglin Liu. Analytic Reconstruction for Parallel Translational Computed Tomography Based on Radon Inverse Transform[J]. Acta Optica Sinica, 2021, 41(6): 0611003
    Download Citation