• Photonics Research
  • Vol. 8, Issue 11, 1676 (2020)
Xiyuan Lu1、2、*, Ashutosh Rao1、3, Gregory Moille1、4, Daron A. Westly1, and Kartik Srinivasan1、4、5
Author Affiliations
  • 1Microsystems and Nanotechnology Division, Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA
  • 2Institute for Research in Electronics and Applied Physics and Maryland NanoCenter, University of Maryland, College Park, Maryland 20742, USA
  • 3Department of Chemistry and Biochemistry, University of Maryland, College Park, Maryland 20742, USA
  • 4Joint Quantum Institute, NIST/University of Maryland, College Park, Maryland 20742, USA
  • 5e-mail: kartik.srinivasan@nist.gov
  • show less
    DOI: 10.1364/PRJ.401755 Cite this Article Set citation alerts
    Xiyuan Lu, Ashutosh Rao, Gregory Moille, Daron A. Westly, Kartik Srinivasan. Universal frequency engineering tool for microcavity nonlinear optics: multiple selective mode splitting of whispering-gallery resonances[J]. Photonics Research, 2020, 8(11): 1676 Copy Citation Text show less

    Abstract

    Whispering-gallery microcavities have been used to realize a variety of efficient parametric nonlinear optical processes through the enhanced light–matter interaction brought about by supporting multiple high quality factor and small modal volume resonances. Critical to such studies is the ability to control the relative frequencies of the cavity modes, so that frequency matching is achieved to satisfy energy conservation. Typically this is done by tailoring the resonator cross section. Doing so modifies the frequencies of all of the cavity modes, that is, the global dispersion profile, which may be undesired, for example, in introducing competing nonlinear processes. Here, we demonstrate a frequency engineering tool, termed multiple selective mode splitting (MSMS), that is independent of the global dispersion and instead allows targeted and independent control of the frequencies of multiple cavity modes. In particular, we show controllable frequency shifts up to 0.8 nm, independent control of the splitting of up to five cavity modes with optical quality factors ?105, and strongly suppressed frequency shifts for untargeted modes. The MSMS technique can be broadly applied to a wide variety of nonlinear optical processes across different material platforms and can be used to both selectively enhance processes of interest and suppress competing unwanted processes.

    1. INTRODUCTION

    Parametric nonlinear optics based on the second-order (χ(2)) or third-order (χ(3)) nonlinear interaction of light has been studied in a variety of optical materials in both nonresonant geometries (bulk crystals, fibers, waveguides) and resonant structures (Fabry–Perot cavities, millimeter-size cavities, and microcavities). Efficient nonlinear mixing based on these processes requires intense light with frequency and phase matching [1,2]. Among these structures, optical microcavities that confine light in whispering-gallery modes (WGMs) with high quality factors and small mode volumes and therefore enhance light–matter interactions in both time and space have been particularly successful [3,4]. However, such an enhancement requires that the interacting WGMs be frequency matched, that is, their resonance frequencies must satisfy energy conservation with an accuracy approximately given by their linewidths. Realization of frequency matching requires consideration of both the specific material platform and the targeted nonlinear optical process.

    WGM microcavities have been extensively studied for parametric nonlinear optics in a variety of material platforms including, but not limited to, silicon [5], silicon nitride [617], silicon carbide [18,19], silicon dioxide [2022], aluminum nitride [2325], gallium arsenide [26,27], magnesium fluoride [2830], and lithium niobate [3135]. Based on these platforms, many nonlinear processes have been demonstrated, including second-harmonic generation [7,17,18,23,3234], third-harmonic generation [7,20,22], optical parametric oscillation [16,19,24,25,29,30,36], four-wave mixing Bragg scattering (FWM-BS) [10], cascaded four-wave mixing [21,28], and electro-optic [35] and dissipative Kerr-soliton [6,8,11,12] frequency comb generation. To match the mode frequencies in these processes, conventional methods demand accurate control of the device geometry (typically the microcavity cross section) to achieve a specific global dispersion profile. Put in other words, all WGMs are shifted together, but in a nonuniform way to achieve frequency matching. Though such conventional methods are particularly suitable for the case of frequency combs, where hundreds of WGMs participate in the nonlinear process, in many other cases the lack of individual mode control is a disadvantage. In particular, there are processes ranging from FWM-BS [10] to widely separated optical parametric oscillation [16] where frequency matching of several (four and three, respectively) targeted modes should be accompanied by frequency mismatching of potentially competing processes. Conventional methods, that is, adjusting the global dispersion profile through the engineering of the resonator cross section, along with postfabrication trimming [16] and thermal tuning [23], may be inadequate in those situations.

    In contrast, direct control of targeted WGM frequencies, without influencing other WGMs, would be a desirable tool for frequency engineering in nanophotonics. One approach towards this end is to couple the clockwise (CW) and counterclockwise (CCW) propagating modes of the resonator and split the cavity resonances. Such mode interactions have often been introduced by random scattering (e.g., by sidewall roughness) in a microcavity [37]; however, this random scattering is difficult to control. Later on, the mode interaction introduced by a foreign point scatterer to a microcavity was studied [38], and is particularly useful for particle sensing [39]. More controllable frequency splitting has been induced using interacting degenerate modes from two [40] or multiple [41] adjacent microcavities. Within one microcavity, the coupling between CW and CCW modes can be realized by integrated distributed Bragg grating reflectors [42], integrated phase shifters [43], and coherent modulation of the boundary, termed selective mode splitting (SMS) [44]. In particular, SMS allows accurate frequency control of a selected cavity mode and has been used to help frequency matching in spontaneous four-wave mixing [44], identify the azimuthal mode numbers of WGMs [9], and offset nonlinear frequency shifts in microcomb generation [45]. Here, we show that its potential for frequency engineering is much greater; it can be controllably applied to multiple modes simultaneously, while leaving untargeted modes nearly unaffected. Such control is of high value to frequency mixing in nonlinear optics, where multiple modes naturally interact.

    We introduce our approach, termed multiple selective mode splitting (MSMS), in the following sections. We first develop a basic model of MSMS using perturbation theory (Section 2). We then examine this idea through experiments (Section 3) that explore the extent to which we can selectively target specified WGMs with a controllable frequency splitting while minimally influencing other (untargeted/collateral) modes. We find that the splitting can be controlled by the modulation amplitude in a linear fashion, and that the collateral splitting is over 13× smaller, even for immediately adjacent WGMs. We then demonstrate several device configurations in which five different WGMs are simultaneously targeted and individually controlled, all while retaining cavity Q>105. We find that MSMS modes have approximately half the waveguide-resonator coupling rate of untargeted modes, consistent with their expected standing-wave nature (Section 4). Finally, we discuss scenarios in which MSMS can be applied to frequency-match nonlinear processes, thereby highlighting the potential broad usage of this technique (Section 5). Although our experiments are implemented in the silicon nitride platform with four-wave mixing processes in mind, the MSMS method is independent of any underlying material platform and the specific resonator global dispersion and can be applied to both χ(2) and χ(3) processes. We therefore believe that MSMS can be a powerful and universal tool to aid frequency engineering in microcavity nonlinear optics.

    2. THEORY

    A rotationally-symmetric (i.e., without azimuthal modulation) microring resonator supports cavity modes propagating in opposite directions, CW and CCW, which are degenerate in frequency ωm0, where m is the azimuthal mode number. A modulation of the microring geometry, for example, of its ring width as shown in Fig. 1(a), with an angular frequency (n oscillations within the ring circumference) matching that of the targeted optical mode n=2m [Figs. 1(d) and 1(e)] introduces coupling, at a rate of βm, between the CW and CCW modes. This coupling lifts their frequency degeneracy and results in standing-wave modes at two new frequencies, ωm±=ωm0±βm, each containing CW and CCW contributions [46]. The standing-wave mode experiencing a smaller (larger) effective ring width has a shorter (longer) resonance wavelength, i.e., a higher (lower) resonance frequency, as shown in Figs. 1(d) and 1(e). Their frequency difference, i.e., the magnitude of the mode splitting 2βm, depends on the amplitude of the geometric modulation applied at that specified angular frequency (An=2m), as shown in Figs. 1(b) and 1(c). Therefore, by changing this modulation amplitude with sufficient resolution, we can precisely control the cavity frequencies. Moreover, for the case n2m, as shown in Fig. 1(f), because the modulation is not in phase with the optical mode, the optical mode should remain unperturbed (except n=0, which corresponds to a uniform change of ring width). This orthonormal property is at the heart of MSMS, as schematically depicted in Fig. 1(a), and can be deduced from a perturbation theory of optical modes with shifting boundaries [47]: where E (D) and E (D) are the electric field components (displacement field components) of the unperturbed optical mode that are parallel () and perpendicular () to the modulation boundary dS, respectively. ϵ represents the dielectric function of the material, including the silicon nitride core (ϵ=ϵc), silicon dioxide substrate, and air cladding (ϵ=1).

    Illustration of MSMS. (a) Example of microring ring width modulation targeting m=6 and m=8 modes, with 20% and 10% of the nominal value (dashed line), respectively. This modulation selectively frequency-splits the (d) m=6 and (e) m=8 modes, while behaving as a normal microring with rotational symmetry for all other modes. We note that the m number and modulation amplitude are quite different than that implemented in real devices, for illustration purposes. (b) The modulation of the ring width for the MSMS device is plotted versus azimuthal angle in the top panel and has two frequency components in this case. The middle panel shows the modulation component targeting the m=6 mode with 20% modulation of the ring width, and the bottom panel shows the modulation component targeting the m=8 mode with 10% modulation of the ring width. (c) In the device transmission (top), this MSMS device introduces frequency splitting of the m=6 and m=8 modes, and the amplitude of the splittings linearly depends on their modulation amplitudes. This transmission trace is equivalent to the two individual SMS transmission traces (middle and bottom) together. (d) For the m=6 mode, the MSMS device is equivalent to the SMS device described by the (6, 0.2) modulated boundary (blue). Degenerate CW and CCW modes are renormalized to two standing-wave modes. The standing-wave mode that always experiences a wider ring width has a larger resonance wavelength, and therefore a redshifted resonance frequency. The other mode always experiences a narrower ring width and is blueshifted. (e) For the m=8 mode, the MSMS device behaves as the SMS device described by the (8, 0.1) boundary (red). (f) For other modes (m≠{6,8}), for example, m=9, the MSMS device does not induce coherent scattering, and therefore behaves similarly to a rotationally symmetric ring (dashed line).

    Figure 1.Illustration of MSMS. (a) Example of microring ring width modulation targeting m=6 and m=8 modes, with 20% and 10% of the nominal value (dashed line), respectively. This modulation selectively frequency-splits the (d) m=6 and (e) m=8 modes, while behaving as a normal microring with rotational symmetry for all other modes. We note that the m number and modulation amplitude are quite different than that implemented in real devices, for illustration purposes. (b) The modulation of the ring width for the MSMS device is plotted versus azimuthal angle in the top panel and has two frequency components in this case. The middle panel shows the modulation component targeting the m=6 mode with 20% modulation of the ring width, and the bottom panel shows the modulation component targeting the m=8 mode with 10% modulation of the ring width. (c) In the device transmission (top), this MSMS device introduces frequency splitting of the m=6 and m=8 modes, and the amplitude of the splittings linearly depends on their modulation amplitudes. This transmission trace is equivalent to the two individual SMS transmission traces (middle and bottom) together. (d) For the m=6 mode, the MSMS device is equivalent to the SMS device described by the (6, 0.2) modulated boundary (blue). Degenerate CW and CCW modes are renormalized to two standing-wave modes. The standing-wave mode that always experiences a wider ring width has a larger resonance wavelength, and therefore a redshifted resonance frequency. The other mode always experiences a narrower ring width and is blueshifted. (e) For the m=8 mode, the MSMS device behaves as the SMS device described by the (8, 0.1) boundary (red). (f) For other modes (m{6,8}), for example, m=9, the MSMS device does not induce coherent scattering, and therefore behaves similarly to a rotationally symmetric ring (dashed line).

    For transverse-electric-field-like (TE) modes or transverse-magnetic-field-like (TM) modes, the above equation can be further simplified because the term containing either D or E dominates the integral in the numerator. Take TE-like modes for example, with the proposed boundary modulation on the ring width: The standing-wave mode with a larger frequency has a dominant displacement field D(r,ϕ,z)=D(r,z)cos(mϕ). Equation (1) can be written as The azimuthal part can thus be integrated separately, where gm is defined as Importantly, Eq. (4) clearly shows that optical modes are only split when they are targeted in the modulation (n=2m). The coupling strength of a targeted mode scales linearly with modulation amplitude (A2m), with a coupling coefficient (gm) defined by Eq. (5). The value of gm can be evaluated from Eq. (4) by a uniform change of ring width (A0). Put in other words, the frequency shift induced by the sinusoidal modulation of A2mcos(2mϕ) is identical to the frequency shift of a uniform ring-width shift of A0=A2m/2. Therefore, in principle, one could split many optical modes with different amounts of mode splitting simply by setting a modulation of the boundary of the ring as in Eq. (2). We note that such a coherent boundary scattering, when operated in a very different regime, that is, n is much smaller than m, can introduce multiple mode couplings to cause a dramatic change of the external cavity field distribution [48]. Such an approach may also enable engineering of cavity mode frequencies, but is outside of the scope of this study.

    3. EXPERIMENTS

    In the previous section, we showed how a simple theory predicts that MSMS should achieve our goals, namely, selective frequency splitting of targeted modes with a controllable splitting amplitude. Next, we examine how well this technique works in practice. Of particular interest is our ability to experimentally create a sufficiently faithful modulation pattern on the inner surface of the microring to realize the mode-selective, adjustable frequency splitting we desire. For this purpose, we use a fabrication process (see Appendix D) in the Si3N4/SiO2 platform without high-temperature annealing and hydrofluoric-acid cleaning processes. Though such processes can reduce optical loss, they are known to influence fabricated dimensions (including smearing out small features by up to several nanometers), and for our purposes here, we desire to keep the fabricated structures as close to the intended designs as possible.

    A. Single-Mode SMS

    We first examine the control of the frequency splitting of a single azimuthal mode, which we term single-mode selective mode splitting (1SMS). Here, we target a fundamental TE mode with m=163, which has resonance around 1550 nm in a device with nominal parameters of a 25 μm outside ring radius, a 1.1 μm ring width, and a 500 nm thickness. Such a structure supports only fundamental radial modes in both TE and TM polarizations. When there is no modulation, as shown in the top panel of Fig. 2(a) and in Fig. 2(c), the cavity transmission consists only of singlet azimuthal modes without any mode splitting. In contrast, when every other parameter is fixed and the ring width is modulated by the function W(ϕ)=3  nm·cos(2×163·ϕ), the mode with m=163 splits into two resonances (85  pm apart), as shown in Fig. 2(d), while all other modes are still singlet resonances without splitting [the second panel of Fig. 2(a)]. A further increase of the modulation amplitude increases the splitting magnitude more, and the 9 and 21 nm modulation cases are shown in the third and fourth panels in Fig. 2(a), with zoom-in traces of the split modes shown in Figs. 2(e) and 2(f).

    1SMS. (a) Transmission scans for four devices with different modulation amplitudes, where the labels (m, A) represent the azimuthal mode number m and the (nominal) modulation amplitude A in nanometers. In the top panel, the control device without SMS shows a cavity transmission spectrum without frequency splitting for any of the modes. From the second panel down, the devices exhibit a transmission spectrum with increasing frequency-splitting for the targeted m=163 mode, with a splitting proportional to the prescribed modulation amplitude. Besides the TE1 modes under investigation, another set of modes appears, which is verified to be fundamental transverse-magnetic modes (TM1). The appearance of these modes is due to wavelength-dependent polarization rotation in the fibers used, which could be resolved by using polarization-maintaining fibers. (b) The top panel shows that the amount of mode splitting is linearly proportional to the modulation amplitude and reaches a value of ≈0.8 nm. The bottom panel shows that the adjacent four modes have much smaller splitting (<7.5% of the targeted mode, that is, below the black line) than the targeted modes. In both panels the uncertainties in the mode splitting, determined from nonlinear least squares fits to the data, are smaller than the data point size. (c) Transmission spectrum and fit trace of the singlet resonance without mode splitting, (163, 0), where Q0 is the intrinsic optical quality factor. (d) Transmission spectrum for the doublet resonance (163, 3), with an observable mode splitting that is a couple of times the mode linewidths. From these linewidths, we determine Q0+ and Q0−, the intrinsic optical quality factors for the blueshifted and redshifted modes, respectively. The differences in the coupling and intrinsic Qs for these two modes are potentially due to the different localization of the two standing-wave modes with respect to the ring-waveguide coupling region and possible point defects, respectively. (e) and (f) Two doublet resonances (163, 9) and (163, 21) that are well separated (262 pm and 591 pm splitting, respectively). See Appendix C for fitting methods.

    Figure 2.1SMS. (a) Transmission scans for four devices with different modulation amplitudes, where the labels (m, A) represent the azimuthal mode number m and the (nominal) modulation amplitude A in nanometers. In the top panel, the control device without SMS shows a cavity transmission spectrum without frequency splitting for any of the modes. From the second panel down, the devices exhibit a transmission spectrum with increasing frequency-splitting for the targeted m=163 mode, with a splitting proportional to the prescribed modulation amplitude. Besides the TE1 modes under investigation, another set of modes appears, which is verified to be fundamental transverse-magnetic modes (TM1). The appearance of these modes is due to wavelength-dependent polarization rotation in the fibers used, which could be resolved by using polarization-maintaining fibers. (b) The top panel shows that the amount of mode splitting is linearly proportional to the modulation amplitude and reaches a value of 0.8  nm. The bottom panel shows that the adjacent four modes have much smaller splitting (<7.5% of the targeted mode, that is, below the black line) than the targeted modes. In both panels the uncertainties in the mode splitting, determined from nonlinear least squares fits to the data, are smaller than the data point size. (c) Transmission spectrum and fit trace of the singlet resonance without mode splitting, (163, 0), where Q0 is the intrinsic optical quality factor. (d) Transmission spectrum for the doublet resonance (163, 3), with an observable mode splitting that is a couple of times the mode linewidths. From these linewidths, we determine Q0+ and Q0, the intrinsic optical quality factors for the blueshifted and redshifted modes, respectively. The differences in the coupling and intrinsic Qs for these two modes are potentially due to the different localization of the two standing-wave modes with respect to the ring-waveguide coupling region and possible point defects, respectively. (e) and (f) Two doublet resonances (163, 9) and (163, 21) that are well separated (262 pm and 591 pm splitting, respectively). See Appendix C for fitting methods.

    In Fig. 2(b), we analyze the dependence on modulation amplitude of the mode splitting for the targeted and untargeted modes. Here, we display data from devices with modulation amplitudes varying from 0 nm to 30 nm with a 3 nm step, with the exception of two cases (15 nm and 27 nm modulation amplitudes) that were damaged during fabrication. In the top panel, we can see a clear linear dependence of the targeted mode splitting versus the modulation amplitude, where the splitting is k=(28±1)  pm per 1 nm modulation of the inside ring width, and the uncertainty is a one standard deviation value based on a fit of the data to a linear function. Importantly, such linear dependence holds true even for a 3 nm modulation amplitude, which is only slightly larger than the pattern resolution (1 nm). On the high amplitude side, at a modulation of 30 nm, the mode splitting approaches 0.8 nm and is not apparently saturated. The extent to which the linear dependence holds for modulation amplitudes <3  nm and >30  nm requires further examination.

    Importantly, the collateral splitting, i.e., the splitting for untargeted modes, is comparatively small. As shown in the bottom panel of Fig. 2(b), the four adjacent modes (m={161,162,164,165}) all exhibit <7.5% of the splitting of the targeted mode (m=163), indicated by the black line. While it is natural to understand the second-most adjacent modes (δm=±2) are less perturbed than the most adjacent modes (δm=±1), it is unclear to us why the δm=2 modes are apparently more affected than δm=2 modes, as the m=161 modes seem not affected at all. Overall, such small collateral splitting supports the theory that, to a significant extent (i.e., <7.5%), untargeted modes are unaffected by the targeted modulation, which makes it possible to extend this mode-splitting method to the regime of controlling multiple modes simultaneously. In particular, the collateral splitting for 3 nm modulation amplitude is near zero (unresolvable in the transmission measurement) for all the untargeted modes, and the modes are well fit to singlet Lorentzians, while the targeted splitting is as large as 85  pm.

    A natural question is whether the introduced modulation adversely affects the modal quality factors. Other works utilizing single-mode splitting [9,45] have observed that high Q>105 can be maintained, and in this work we consistently observe Q105 when large-mode splittings are realized. In fact, to our surprise, with a larger mode splitting, the Qs are not decreased but are actually increased compared to the zero-splitting or small-splitting case (see Appendix A). We also observe an increase in Q for devices employing MSMS versus SMS, which is discussed later in Section 5. Finally, we note that the devices studied in this work have intrinsic Qs that are in general about 10 times smaller than the state of the art for Si3N4 microrings (Q0106). We believe this is at least partly due to the conservative nanofabrication method used in this work (in particular, avoiding the high-temperature annealing step). In Appendix E, we present measurements of a device in which annealing and postfabrication wet etching are used to improve the material/surface quality, resulting in Qs approaching 106 for mode-splitting levels in excess of 1.6 nm. Further study is required to determine what fundamental limitations in Q the adoption of SMS/MSMS imposes, and to what extent these postfabrication processes can mitigate loss while retaining adequate pattern fidelity.

    B. Multiple SMS

    We now set up the modulation of the inner ring boundary to target multiple modes, considering both three modes (3SMS) and five modes (5SMS). As the results are qualitatively quite similar (other than the number of targeted modes), we focus on the 5SMS cases in the main text, with the 3SMS case considered in Appendix B. In both cases, the modulation is simply a superposition of sinusoids, with frequencies chosen in accordance with the targeted azimuthal modes and amplitudes that can be adjusted as desired.

    For 5SMS, we consider five devices with different modulation configurations, and their measured transmission traces are shown in Fig. 3(a). The modulated modes are labeled by (m, A), where m represents the mode number (from 159 to 167), and A represents the modulation amplitude in nanometers (either 5 nm or 15 nm). The measured mode splittings are shown in Fig. 3(b), with the pattern matching the targeted configuration very well—only targeted modes show significant mode splitting and the splittings are independently adjustable (even for adjacent modes). For example, device I has an average collateral splitting of (9.6±4.2) pm, which is 6.5% of the targeted splitting (148±6) pm; device IV has an average collateral splitting of (27±12) pm, which is 7.2% of the targeted splitting (375±15) pm. Though small, these collateral splittings indicate that the fabricated modulation pattern on the inner ring sidewall is imperfect, and contains undesired nonzero spatial Fourier components. Nevertheless, this first demonstration of independent frequency control of multiple whispering-gallery modes represents a significant advance in microcavity frequency engineering, beyond global resonator dispersion engineering based on changing the geometric cross section [49] or techniques such as quasi-phase matching [31,33]. In Section 5, we discuss how this type of modal frequency control can be applied to different nonlinear optical processes.

    5SMS. (a) Cavity transmission traces of five devices with different configurations of 5SMS. Each split mode is labeled by (m, A), with A in units of nanometers. (b) The measured mode-splitting amounts clearly correspond to the expected modulation pattern, where A=15 nm and A=5 nm ring width modulation amplitudes correspond to (390±20) pm and (140±10) pm mode splittings, while the untargeted modes have ≈7% collateral splitting. The slopes (splitting divided by the modulation amplitude) are (26±1) pm/nm and (28±2) pm/nm, respectively, close to the 1SMS slope in Fig. 2(b). The uncertainties in mode splitting are smaller than the data point size. (c) Typical example of the cavity transmission for a targeted mode with 408 pm mode splitting; (d) typical example of the cavity transmission of a targeted mode with 140 pm mode splitting; (e) the average of the intrinsic optical quality factors of all the modes in these 5SMS devices is, surprisingly, more than 1 standard deviation higher than the average in the 1SMS devices (red open circles). Qs for individual modes are shown as solid blue dots. We note that the Qs of 1SMS modes are generally higher with >20 nm modulation amplitude (see Appendix A). The 3SMS devices (where three modes are targeted for mode splitting) have Qs that are in-between the 1SMS and 5SMS cases (see Appendix B).

    Figure 3.5SMS. (a) Cavity transmission traces of five devices with different configurations of 5SMS. Each split mode is labeled by (m, A), with A in units of nanometers. (b) The measured mode-splitting amounts clearly correspond to the expected modulation pattern, where A=15  nm and A=5  nm ring width modulation amplitudes correspond to (390±20)  pm and (140±10)  pm mode splittings, while the untargeted modes have 7% collateral splitting. The slopes (splitting divided by the modulation amplitude) are (26±1)  pm/nm and (28±2)  pm/nm, respectively, close to the 1SMS slope in Fig. 2(b). The uncertainties in mode splitting are smaller than the data point size. (c) Typical example of the cavity transmission for a targeted mode with 408 pm mode splitting; (d) typical example of the cavity transmission of a targeted mode with 140 pm mode splitting; (e) the average of the intrinsic optical quality factors of all the modes in these 5SMS devices is, surprisingly, more than 1 standard deviation higher than the average in the 1SMS devices (red open circles). Qs for individual modes are shown as solid blue dots. We note that the Qs of 1SMS modes are generally higher with >20  nm modulation amplitude (see Appendix A). The 3SMS devices (where three modes are targeted for mode splitting) have Qs that are in-between the 1SMS and 5SMS cases (see Appendix B).

    Clearly, selective frequency control of multiple cavity modes is of most benefit if the cavity Qs remain high. Counterintuitively, we have observed that the complicated modulation patterns that split five cavity modes do not decrease the Q of the devices, but increase them instead. This trend is displayed in Fig. 3(e). Here, for the 3SMS and 5SMS devices, all targeted modes, as well as the two adjacent modes, are analyzed and the resulting mean Q and 1 standard deviation spread in the Q are shown. For the 1SMS, the displayed data are based on results from all modulation amplitudes, for which we note that a larger modulation amplitude tends to increase the optical Q as well (see Appendix A). Importantly, these devices are fabricated on the same chip, so this trend is seemingly unlikely to be due to fabrication fluctuation. The fundamental physical reasoning behind this relative increase in Q with increasing modulation amplitude and number of split modes requires further investigation and may be specific to the Qs observed in this work (5×104 to 1.5×105), as opposed to being a more universal trend for any Qs. Nevertheless, we note that the optical Qs achieved (105) for large-mode splitting amplitudes (up to 430 pm) are already very promising for the usage of MSMS in nonlinear optics.

    C. Microring-Waveguide Coupling

    Aside from the change in intrinsic optical Q introduced by MSMS, we also observe a change in the extrinsic (coupling) optical Q, which is related to the microring-waveguide coupling rate Γc by Qc=ω/Γc. In theory, traveling-wave modes and standing-wave modes should have different coupling rates [46], as illustrated in Fig. 4(a). Light propagating in the forward direction from a waveguide underneath the microring couples to the microring CCW traveling-wave mode at a rate of Γc, while the traveling-wave mode in the other direction, the CW mode, is uncoupled. In the MSMS case, the modes are standing waves, which are equally composed of CCW and CW components. Therefore, the forward propagating waveguide mode only directly excites the CCW part, leading to an overall reduction of the coupling rate to Γc/2, and therefore an increase in Qc by a factor of 2 relative to the traveling-wave case.

    Microring-waveguide coupling. (a) In an MSMS device, targeted modes become standing waves that equally comprise a CCW (red) part and a CW (black) part. Assuming a undirectional waveguide input as shown in the diagram, the CCW part can be coupled to at a rate Γc=Γccw, while the CW part is not directly coupled to the waveguide because of the large momentum mismatch from the input light (Γc=0). The MSMS modes are therefore expected to have an overall coupling rate of Γc=Γccw/2 in theory. (b) Considering a 5SMS device in which the m={159,161,163,165,167} modes are targeted, the measured Qc (blue) is clearly larger for the split modes (each indicated by a black dashed line) than for other modes, and therefore Qc as a function of azimuthal mode order shows an oscillatory behavior. Dividing Qc for the split modes by 2 yields inferred values of their CCW coupling Q (red), which are similar to those of the unsplit modes. This trend is consistent with the prediction in (a), as Qc=ω/Γc. Error bars are 1 standard deviation values resulting from nonlinear least squares fits to the data.

    Figure 4.Microring-waveguide coupling. (a) In an MSMS device, targeted modes become standing waves that equally comprise a CCW (red) part and a CW (black) part. Assuming a undirectional waveguide input as shown in the diagram, the CCW part can be coupled to at a rate Γc=Γccw, while the CW part is not directly coupled to the waveguide because of the large momentum mismatch from the input light (Γc=0). The MSMS modes are therefore expected to have an overall coupling rate of Γc=Γccw/2 in theory. (b) Considering a 5SMS device in which the m={159,161,163,165,167} modes are targeted, the measured Qc (blue) is clearly larger for the split modes (each indicated by a black dashed line) than for other modes, and therefore Qc as a function of azimuthal mode order shows an oscillatory behavior. Dividing Qc for the split modes by 2 yields inferred values of their CCW coupling Q (red), which are similar to those of the unsplit modes. This trend is consistent with the prediction in (a), as Qc=ω/Γc. Error bars are 1 standard deviation values resulting from nonlinear least squares fits to the data.

    We indeed observe this coupling behavior in experiment. For the 5SMS device targeting azimuthal mode orders m={159,161,163,165,167} with a 5 nm modulation amplitude each [top panel in Figs. 3(a) and 3(b)], the coupling Qs of the optical modes are shown in Fig. 4(b), confirming the increase of Qc for the targeted modes (versus that for the untargeted modes). Dividing the coupling Qs of the targeted modes by two (dashed lines) results in them having similar coupling Qs as the untargeted modes. There is an overall trend in coupling Q for which larger m modes (corresponding to smaller resonance wavelengths) generally exhibit worse coupling (larger Qc). This is a consequence of the evanescent mode overlap between waveguide and resonator modes decreasing at shorter wavelengths.

    4. APPLICATION SCENARIOS

    In previous sections, we have shown that MSMS can be a tool to split multiple cavity modes with a prescribed configuration of mode numbers and splitting amplitudes while retaining optical Q105. The induced modes are standing wave in nature and thus have a reduced microring–waveguide coupling rate relative to traveling-wave modes. Although some aspects of the MSMS approach require further investigation and optimization, we believe that the demonstrated performance would already be of utility for many nonlinear optical applications. Here, we consider an example that showcases this capability. In comparison to a typical microring cavity [Fig. 5(a)], we use MSMS to frequency split two modes on demand (mi, mj) [Fig. 5(b)]. Such on-demand two-mode splitting can be easily achieved based on the approach demonstrated in the previous section. We now discuss how this 2SMS microring can be used in the context of three four-wave mixing processes.

    Nonlinear optics applications for the two-mode selective mode splitting (2SMS) case. (a) In the case of a conventional WGM microcavity (left column), realizing an efficient parametric nonlinear process relies on finding a device geometry whose global dispersion profile results in frequency matching for the modes of interest for a given nonlinear optical process, e.g., (I) intraband and (II) interband frequency conversion via FWM-BS, and (III) photon-pair generation. (b) In contrast, by using a 2SMS device (right column), frequency matching can be achieved without any specific consideration of the global dispersion profile (and hence the resonator cross section), so that any of the displayed nonlinear processes can be achieved. For intraband FWM-BS in a conventional microcavity [I(a)], global dispersion engineering typically leads to an unwanted conversion channel (dashed arrow) along with the targeted channel (solid arrow). But in an MSMS cavity, FWM-BS naturally occurs for only a single set of modes [solid arrows in I(b)]. Moreover, MSMS modes can be used in flexible ways, either exclusively MSMS modes [I(b)1], or combined with unsplit modes [I(b)2]. This MSMS cavity can also be applied to interband FWM-BS (II) and nondegenerately pumped photon pair generation (III) in similar ways, not only relaxing the frequency engineering for the targeted process (solid arrows), but also enabling suppression of the unwanted process [dashed arrows in I(a)–III(a)].

    Figure 5.Nonlinear optics applications for the two-mode selective mode splitting (2SMS) case. (a) In the case of a conventional WGM microcavity (left column), realizing an efficient parametric nonlinear process relies on finding a device geometry whose global dispersion profile results in frequency matching for the modes of interest for a given nonlinear optical process, e.g., (I) intraband and (II) interband frequency conversion via FWM-BS, and (III) photon-pair generation. (b) In contrast, by using a 2SMS device (right column), frequency matching can be achieved without any specific consideration of the global dispersion profile (and hence the resonator cross section), so that any of the displayed nonlinear processes can be achieved. For intraband FWM-BS in a conventional microcavity [I(a)], global dispersion engineering typically leads to an unwanted conversion channel (dashed arrow) along with the targeted channel (solid arrow). But in an MSMS cavity, FWM-BS naturally occurs for only a single set of modes [solid arrows in I(b)]. Moreover, MSMS modes can be used in flexible ways, either exclusively MSMS modes [I(b)1], or combined with unsplit modes [I(b)2]. This MSMS cavity can also be applied to interband FWM-BS (II) and nondegenerately pumped photon pair generation (III) in similar ways, not only relaxing the frequency engineering for the targeted process (solid arrows), but also enabling suppression of the unwanted process [dashed arrows in I(a)–III(a)].

    We first consider FWM-BS, which is a theoretically noiseless process for frequency conversion down to the single-photon level [50]. Recently, this process has been demonstrated in silicon nitride microrings [10], with intraband conversion (few nanometer spectral shifts) demonstrated for a quantum dot single-photon source [14] and a spontaneous four-wave mixing source [15]. This intraband FWM-BS process involved two spectral bands that are widely separated from each other, with the pump modes, shown in blue in Fig. 5(I(a)), situated in one band and the signal and idler modes (shown in red), situated in the other band. Frequency matching requires the signal-idler mode separation to equal the pump mode separation, and though achievable through global dispersion engineering that results in an equal free spectral range (FSR) in the two bands [10], there are limitations of that approach. In particular, the wavelength shift is restricted to being a multiple of the FSR (modulo the cavity linewidth), and the smallest achievable shift is thus largely dictated by the ring radius. Moreover, frequency up- and down-shifts are realized simultaneously, as the equal FSR condition means that both idlers are equally well frequency matched. In contrast, the 2SMS case, shown in Fig. 5(I(b)), does not require any specific device dispersion or cross-sectional geometry. The achievable frequency shift is not limited to multiples of the resonator FSR, and very small frequency shifts can be achieved without going to very large resonator size. Moreover, in most cases, no other set of modes will be frequency matched, eliminating this competitive channel for frequency conversion, which is nontrivial to implement in a conventional design [15]. We note that this MSMS configuration can also be applied to interband frequency conversion based on FWM-BS [Fig. 5(II)], where in this case there are pump modes in each of the two spectral bands, and their frequency separation can be made to match the signal-idler mode frequency separation, so that large spectral shifts can be achieved [10].

    Similarly, the same MSMS scheme can be used in photon pair generation. In previous work, for example, telecom-band pair sources [13] and visible-telecom pair sources [9], dispersion had to be tailored to phase- and frequency-match targeted modes (solid arrows), and unwanted photon pair channels (dashed arrows) need to be carefully suppressed, as shown in Fig. 5(III(a)). But in the MSMS case [Fig. 5(III(b))], the global dispersion profile is not important, and in fact, most geometries with nonzero dispersion will leads to noiseless photon pair generation, where all other mode configurations are not matched in frequency and phase. We note that, for specificity, we have shown a nondegenerate pumping configuration here, but there are many other configurations (including typical degenerate pumping) to which MSMS can be applied. A full discussion of such configurations would be valuable but is beyond the scope of this paper.

    Finally, we note that the standing-wave nature of the MSMS modes must be carefully considered in the context of the applications being discussed. These standing waves are intrinsically a superposition state of CW and CCW modes, a property that could be useful for helping in the generation of orbital angular momentum in single-photon sources [51] and for enabling CW/CCW path entanglement [52]. On the other hand, in many cases we want the output signal to exit the cavity in one direction, which will not be the case for standing-wave modes. However, we note that the MSMS approach can still be valuable in such situations. In particular, frequency splitting may only be applied to pump modes, or MSMS may be used exclusively to frequency mismatch unwanted processes, while the process of interest is still accomplished using the typical traveling-wave modes.

    5. CONCLUSIONS

    In summary, we demonstrate a nanophotonic frequency engineering tool, MSMS, which manipulates multiple targeted cavity mode frequencies with individually controlled amounts of splitting. Such mode shifts can be large in amplitude (up to 0.8  nm), small in cross talk (less than 7.5% for untargeted modes), and high-Q (105). The MSMS tool enables unique frequency engineering capabilities beyond traditional techniques, can be universally applied regardless of materials and geometries, and will have broad applications in microcavity nonlinear photonics.

    APPENDIX A: SMS Q ANALYSIS

    In this section, we show additional data on the intrinsic and coupling Q analysis for the single-mode SMS devices. In Fig.?6(a), we see that the SMS modes (shown in red and blue) have similar intrinsic optical Qs as the untargeted modes (shown in gray). Moreover, surprisingly, larger modulation amplitudes have higher intrinsic Qs than nonmodulated devices. In particular, for a modulation amplitude of 21?nm, the modes have Q>105. However, this trend requires further verification through additional device fabrication and characterization in the future.

    1SMS Q analysis. (a) The intrinsic optical Qs of the SMS modes (red and blue) are consistent with the values from untargeted modes (gray data indicate 1 standard-deviation range given by fits to the four adjacent resonances). (b) The coupling Qs of the SMS modes (red and blue) are statistically larger than the values from untargeted modes (1 standard-deviation range found by fits of the four adjacent resonances shown in gray), as expected based on their standing-wave nature. Dividing the coupling Q of the targeted modes by two gives values (indicated by the red and blue dashed lines) that are within the range of Q values from other modes, consistent with expectation from theory.

    Figure 6.1SMS Q analysis. (a) The intrinsic optical Qs of the SMS modes (red and blue) are consistent with the values from untargeted modes (gray data indicate 1 standard-deviation range given by fits to the four adjacent resonances). (b) The coupling Qs of the SMS modes (red and blue) are statistically larger than the values from untargeted modes (1 standard-deviation range found by fits of the four adjacent resonances shown in gray), as expected based on their standing-wave nature. Dividing the coupling Q of the targeted modes by two gives values (indicated by the red and blue dashed lines) that are within the range of Q values from other modes, consistent with expectation from theory.

    The coupling Q shows a statistical difference for SMS modes and untargeted modes. In Fig.?6(b), we show that coupling Q of the SMS modes is in general larger (by about a factor of 2) than those values from the untargeted modes, which agrees with the results in Section?4 in the main text.

    APPENDIX B: ADDITIONAL THREE-MODE DATA

    In the main text, we presented the compiled Q data from 5SMS devices in Fig.?3(e) to examine the trend in intrinsic Q versus number of split modes. Here we show extended data from the 3SMS devices, where we target different WGMs with varying splitting levels. The results, shown in Fig.?7, are similar to the 5SMS devices.

    3SMS results. (a) Cavity transmission for four devices with different configuration of 3SMS. The modulated modes are labeled as (m, A), where m represents the azimuthal mode number, and A represents its modulation amplitude in nanometers. (b) The measured mode splittings clearly show the targeted control of three modes with a splitting amplitude proportional to the modulation amplitude. (c)–(e) Optical Q fitting examples for modulation amplitudes of 15 nm, 5 nm, and 0 nm, respectively.

    Figure 7.3SMS results. (a) Cavity transmission for four devices with different configuration of 3SMS. The modulated modes are labeled as (m, A), where m represents the azimuthal mode number, and A represents its modulation amplitude in nanometers. (b) The measured mode splittings clearly show the targeted control of three modes with a splitting amplitude proportional to the modulation amplitude. (c)–(e) Optical Q fitting examples for modulation amplitudes of 15 nm, 5 nm, and 0 nm, respectively.

    APPENDIX C: FITTING METHOD

    We explain our fitting method for singlet and doublet cavity resonances, following the method in Ref.?[46]. In general, there are three cases in Q fitting. First, the resonance is a singlet resonance without an observable splitting [e.g., Fig.?7(e)]. Second, the resonance is a doublet resonance [e.g., Fig.?7(d)]. Third, the resonance has a large-mode splitting, so that each mode looks like a singlet resonance [e.g., Fig.?7(c)]. In the first case, we fit the resonance by a Lorentzian function, whose full width at half-maximum yields the loaded optical quality (Qt), and its transmission depth yields the ratio of Q0 and Qc. In this work, cavity modes are all undercoupled; therefore Q0<Qc. In the second case, we fit the resonances as two standing-wave modes that share the same coupling rate with three parameters, {Q0+, Q0?, Qc}. In the third case, we fit each standing-wave mode separately as an individual singlet and allow these two modes to have different coupling Q values (i.e., fitting {Q0+, Qc+} and {Q0?, Qc?}, respectively).

    APPENDIX D: FABRICATION METHOD

    The device layout was done with the Nanolithography Toolbox, a free software package developed by the NIST Center for Nanoscale Science and Technology [53]. The Si3N4 layer is deposited by low-pressure chemical vapor deposition on top of a 3?μm thick thermal SiO2 layer on a 100?mm diameter Si wafer. The wavelength-dependent refractive index and the thickness of the layers are measured using a spectroscopic ellipsometer, with the data fit to an extended Sellmeier model. Next, the device pattern is created in positive-tone resist by electron-beam lithography. The pattern is then transferred to Si3N4 by reactive ion etching using a CF4/CHF3 chemistry. The device is chemically cleaned to remove deposited polymer and remnant resist. An oxide lift-off process is performed so that the microrings have an air cladding on top while the input/output edge-coupler waveguides have SiO2 on top to form more symmetric modes for coupling to optical fibers. The facets of the chip are then polished for lensed fiber coupling.

    APPENDIX E: HIGHER Q DEVICES

    In Fig.?8, we show transmission data of a device before and after postprocessing (consisting of annealing and dilute hydrofluoric acid etching) to demonstrate that a large-mode-splitting device can have optical quality factors approaching 106. Although its effect on the pattern accuracy needs further study, high-Q modes approaching 7.6×105 are possible with 1.62??nm splitting. Such high-Q and controllable mode splitting is very promising for nonlinear optical applications.

    High-Q 1SMS devices. (a) An optimized etching process leads to a device with intrinsic Q of 2.5×105 for a mode with a 1.75 nm splitting. (b) With postprocessing steps consisting of annealing and dilute hydrofluoric acid etching, the device has shifted resonances with intrinsic Q improved to 7.6×105 and decreased splitting of 1.62 nm.

    Figure 8.High-Q 1SMS devices. (a) An optimized etching process leads to a device with intrinsic Q of 2.5×105 for a mode with a 1.75 nm splitting. (b) With postprocessing steps consisting of annealing and dilute hydrofluoric acid etching, the device has shifted resonances with intrinsic Q improved to 7.6×105 and decreased splitting of 1.62 nm.

    References

    [1] G. Agrawal. Nonlinear Fiber Optics(2007).

    [2] R. W. Boyd. Nonlinear Optics(2008).

    [3] K. J. Vahala. Optical microcavities. Nature, 424, 839-846(2003).

    [4] D. V. Strekalov, C. Marquardt, A. B. Matsko, H. G. L. Schwefel, G. Leuchs. Nonlinear and quantum optics with whispering gallery resonators. J. Opt., 18, 123002(2016).

    [5] J. Leuthold, C. Koos, W. Freude. Nonlinear silicon photonics. Nat. Photonics, 4, 535-544(2010).

    [6] Y. Okawachi, K. Saha, J. S. Levy, Y. H. Wen, M. Lipson, A. L. Gaeta. Octave-spanning frequency comb generation in a silicon nitride chip. Opt. Lett., 36, 3398-3400(2011).

    [7] J. S. Levy, M. A. Foster, A. L. Gaeta, M. Lipson. Harmonic generation in silicon nitride ring resonators. Opt. Express, 19, 11415-11421(2011).

    [8] F. Ferdous, H. Miao, D. E. Leaird, K. Srinivasan, J. Wang, L. Chen, L. T. Varghese, A. M. Weiner. Spectral line-by-line pulse shaping of on-chip microresonator frequency combs. Nat. Photonics, 5, 770-776(2011).

    [9] X. Lu, Q. Li, D. A. Westly, G. Moille, A. Singh, V. Anant, K. Srinivasan. Chip-integrated visible-telecom photon pair sources for quantum communication. Nat. Phys., 15, 373-381(2019).

    [10] Q. Li, M. Davanço, K. Srinivasan. Efficient and low-noise single-photon-level frequency conversion interfaces using silicon nanophotonics. Nat. Photonics, 10, 406-414(2016).

    [11] Q. Li, T. C. Briles, D. A. Westly, T. E. Drake, J. R. Stone, B. R. Ilic, S. A. Diddams, S. B. Papp, K. Srinivasan. Stably accessing octave-spanning microresonator frequency combs in the soliton regime. Optica, 4, 193-203(2017).

    [12] M. Karpov, M. H. Pfeiffer, J. Liu, A. Lukashchuk, T. J. Kippenberg. Photonic chip-based soliton frequency combs covering the biological imaging window. Nat. Commun., 9, 1146(2018).

    [13] F. Samara, A. Martin, C. Autebert, M. Karpov, T. J. Kippenberg, H. Zbinden, R. Thew. High-rate photon pairs and sequential time-bin entanglement with Si3N4 microring resonators. Opt. Express, 27, 19309-19318(2019).

    [14] A. Singh, Q. Li, S. Liu, Y. Yu, X. Lu, C. Schneider, S. Höfling, J. Lawall, V. Verma, R. Mirin, S. W. Nam, J. Liu, K. Srinivasan. Quantum frequency conversion of a quantum dot single-photon source on a nanophotonic chip. Optica, 6, 563-569(2019).

    [15] Q. Li, A. Singh, X. Lu, J. Lawall, V. Verma, R. Mirin, S. W. Nam, K. Srinivasan. Tunable quantum beat of single photons enabled by nonlinear nanophotonics. Phys. Rev. Appl., 12, 054054(2019).

    [16] X. Lu, G. Moille, A. Singh, Q. Li, D. A. Westly, A. Rao, S.-P. Yu, T. C. Briles, S. B. Papp, K. Srinivasan. Milliwatt-threshold visible-telecom optical parametric oscillation using silicon nanophotonics. Optica, 6, 1535-1541(2019).

    [17] X. Lu, G. Moille, A. Rao, D. A. Westly, K. Srinivasan. Efficient photo-induced second harmonic generation in silicon photonics(2020).

    [18] D. M. Lukin, C. Dory, M. A. Guidry, K. Y. Yang, S. D. Mishra, R. Trivedi, M. Radulaski, S. Sun, D. Vercruysse, G. H. Ahn, J. Vučković. 4H-silicon-carbide-on-insulator for integrated quantum and nonlinear photonics. Nat. Photonics, 14, 330-334(2020).

    [19] M. A. Guidry, K. Y. Yang, D. M. Lukin, A. Markosyan, J. Yang, M. M. Fejer, J. Vučković. Optical parametric oscillation in silicon carbide nanophotonics. Optica, 7, 1139-1142(2020).

    [20] T. Carmon, K. J. Vahala. Visible continuous emission from a silica microphotonic device by third-harmonic generation. Nat. Phys., 3, 430-435(2007).

    [21] S. Fujii, T. Kato, R. Suzuki, T. Tanabe. Third-harmonic blue light generation from Kerr clustered combs and dispersive waves. Opt. Lett., 42, 2010-2013(2017).

    [22] J. H. Chen, X. Shen, S. J. Tang, Q. T. Cao, Q. Gong, Y. F. Xiao. Microcavity nonlinear optics with an organically functionalized surface. Phys. Rev. Lett., 123, 173902(2019).

    [23] X. Guo, C.-L. Zou, H. X. Tang. Second-harmonic generation in aluminum nitride microrings with 2500%/W conversion efficiency. Optica, 3, 1126-1131(2016).

    [24] A. W. Bruch, X. Liu, J. B. Surya, C.-L. Zou, H. X. Tang. On-chip χ(2) microring optical parametric oscillator. Optica, 6, 1361-1366(2019).

    [25] Y. Tang, Z. Gong, X. Liu, H. X. Tang. Widely separated optical Kerr parametric oscillation in AlN microrings. Opt. Lett., 45, 1124-1127(2020).

    [26] P. S. Kuo, J. Bravo-Abad, G. S. Solomon. Second-harmonic generation using quasi-phasematching in a GaAs whispering-gallery-mode microcavity. Nat. Commun., 5, 3109(2014).

    [27] L. Chang, A. Boes, P. Pintus, J. D. Peters, M. Kennedy, X. Guo, N. Volet, S. Yu, S. B. Papp, J. E. Bowers. Strong frequency conversion in heterogeneously integrated GaAs resonators. APL Photon., 4, 036103(2019).

    [28] W. Liang, A. A. Savchenkov, Z. Xie, J. F. McMillan, J. Burkhart, V. S. Ilchenko, C. W. Wong, A. B. Matsko, L. Maleki. Miniature multioctave light source based on a monolithic microcavity. Optica, 2, 40-47(2015).

    [29] N. L. B. Sayson, T. Bi, V. Ng, H. Pham, L. S. Trainor, H. G. L. Schwefel, S. Coen, M. Erkintalo, S. G. Murdoch. Octave-spanning tunable parametric oscillation in crystalline Kerr microresonators. Nat. Photonics, 13, 701-707(2019).

    [30] S. Fujii, S. Tanaka, M. Fuchida, H. Amano, Y. Hayama, R. Suzuki, Y. Kakinuma, T. Tanabe. Octave-wide phase-matched four-wave mixing in dispersion engineered crystalline microresonators. Opt. Lett., 42, 3146-3149(2019).

    [31] V. S. Ilchenko, A. A. Savchenkov, A. B. Matsko, L. Maleki. Nonlinear optics and crystalline whispering gallery mode cavities. Phys. Rev. Lett., 92, 043903(2004).

    [32] J. Lin, Y. Xu, J. Ni, M. Wang, Z. Fang, L. Qiao, W. Fang, Y. Cheng. Phase-matched second-harmonic generation in an on-chip LiNbO3 microresonator. Phys. Rev. Appl., 6, 014002(2016).

    [33] J. Lu, J. B. Surya, X. Liu, A. W. Bruch, Z. Gong, Y. Xu, H. X. Tang. Periodically poled thin-film lithium niobate microring resonators with a second-harmonic generation efficiency of 250,000%/W. Optica, 6, 1455-1460(2019).

    [34] R. Luo, H. Jiang, S. Rogers, H. Liang, Y. He, Q. Lin. On-chip second-harmonic generation and broadband parametric down-conversion in a lithium niobate microresonator. Opt. Express, 25, 24531-24539(2017).

    [35] M. Zhang, B. Buscaino, C. Wang, A. Shams-Ansari, C. Reimer, R. Zhu, J. M. Kahn, M. Lon. Broadband electro-optic frequency comb generation in a lithium niobate microring resonator. Nature, 568, 373-377(2019).

    [36] T. J. Kippenberg, S. Spillane, K. J. Vahala. Kerr-nonlinearity optical parametric oscillation in an ultrahigh-Q toroid microcavity. Phys. Rev. Lett., 93, 083904(2004).

    [37] D. S. Weiss, V. Sandoghdar, J. Hare, V. Lefèvre-Seguin, J.-M. Raimond, S. Haroche. Splitting of high-Q Mie modes induced by light backscattering in silica microspheres. Opt. Lett., 20, 1835-1837(1995).

    [38] A. Mazzei, S. Götzinger, L. de S. Menezes, G. Zumofen, O. Benson, V. Sandoghdar. Controlled coupling of counterpropagating whispering-gallery modes by a single Rayleigh scatterer: a classical problem in a quantum optical light. Phys. Rev. Lett., 99, 173603(2007).

    [39] J. Zhu, S. Ozdemir, Y.-F. Xiao, L. Li, L. He, D.-R. Chen, L. Yang. On-chip single nanoparticle detection and sizing by mode splitting in an ultrahigh-Q microresonator. Nat. Photonics, 4, 46-49(2010).

    [40] C. M. Gentry, X. Zeng, M. A. Popović. Tunable coupled-mode dispersion compensation and its application to on-chip resonant four-wave mixing. Opt. Lett., 39, 5689-5692(2014).

    [41] D. D. Smith, H. Chang, K. A. Fuller. Whispering-gallery mode splitting in coupled microresonators. J. Opt. Soc. Am. B, 18, 1967-1974(2003).

    [42] A. Arbabi, Y. M. Kang, C.-Y. Lu, E. Chow, L. L. Goddard. Realization of a narrowband single wavelength microring mirror. Appl. Phys. Lett., 99, 091105(2011).

    [43] A. Li, W. Bogaerts. Experimental demonstration of a single silicon ring resonator with an ultra-wide FSR and tuning range. Opt. Lett., 42, 4986-4989(2017).

    [44] X. Lu, S. Rogers, W. C. Jiang, Q. Lin. Selective engineering of cavity resonance for frequency matching in optical parametric processes. Appl. Phys. Lett., 105, 151104(2014).

    [45] S.-P. Yu, D. C. Cole, H. Jung, G. T. Moille, K. Srinivasan, S. B. Papp. Spontaneous pulse formation in edge-less photonic crystal resonators(2020).

    [46] M. Borselli, T. J. Johnson, O. Painter. Beyond the Rayleigh scattering limit in high-Q silicon microdisks: theory and experiment. Opt. Express, 13, 1515-1530(2005).

    [47] S. G. Johnson, M. Ibanescu, M. A. Skorobogatiy, O. Weisberg, J. D. Joannopoulos, Y. Fink. Perturbation theory for Maxwell’s equations with shifting material boundaries. Phys. Rev. E, 65, 066611(2002).

    [48] L. Ge, Q. Song, B. Redding, A. Ebersper, J. Wiersig, H. Cao. Controlling multimode coupling by boundary-wave scattering. Phys. Rev. A, 88, 043801(2013).

    [49] D. J. Moss, R. Morandotti, A. L. Gaeta, M. Lipson. New CMOS-compatible platforms based on silicon nitride and Hydex for nonlinear optics. Nat. Photonics, 7, 597-607(2013).

    [50] C. J. McKinstrie, J. D. Harvey, S. Radic, M. G. Raymer. Translation of quantum states by four-wave mixing in fibers. Opt. Express, 13, 9131-9142(2005).

    [51] B. Chen, Y. Wei, T. Zhao, S. Liu, B. Yao, Y. Yu, J. Liu, X.-H. Wang. A highly efficient integrated source of twisted single-photons(2020).

    [52] S. D. Rogers, A. Graf, U. A. Javid, Q. Lin. Coherent quantum dynamics of systems with coupling-induced creation pathways. Commun. Phys., 2, 95(2019).

    [53] K. C. Balram, D. A. Westly, M. I. Davanco, K. E. Grutter, Q. Li, T. Michels, C. H. Ray, R. J. Kasica, C. B. Wallin, I. J. Gilbert, B. A. Bryce, G. Simelgor, J. Topolancik, N. Lobontiu, Y. Liu, P. Neuzil, V. Svatos, K. A. Dill, N. A. Bertrand, M. Metzler, G. Lopez, D. Czaplewski, L. Ocola, K. A. Srinivasan, S. M. Stavis, V. A. Aksyuk, J. A. Liddle, S. Krylov, B. R. Ilic. The nanolithography toolbox. J. Res. Natl. Inst. Stand. Technol., 121, 464-475(2016).

    Xiyuan Lu, Ashutosh Rao, Gregory Moille, Daron A. Westly, Kartik Srinivasan. Universal frequency engineering tool for microcavity nonlinear optics: multiple selective mode splitting of whispering-gallery resonances[J]. Photonics Research, 2020, 8(11): 1676
    Download Citation