• Acta Optica Sinica
  • Vol. 40, Issue 22, 2211002 (2020)
Zhongjian Tian1, Haijun Yu2、3, Linbo Wang1, Zhenzhen Pi1, and Fenglin Liu1、2、3、*
Author Affiliations
  • 1State Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing 400044, China
  • 2Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, China
  • 3Engineering Research Center of Industrial Computed Tomography Nondestructive Testing, Ministry of Education, Chongqing University, Chongqing 400044, China
  • show less
    DOI: 10.3788/AOS202040.2211002 Cite this Article Set citation alerts
    Zhongjian Tian, Haijun Yu, Linbo Wang, Zhenzhen Pi, Fenglin Liu. Orthogonal Translation Computed Laminography[J]. Acta Optica Sinica, 2020, 40(22): 2211002 Copy Citation Text show less
    References

    [1] Zhang Y B, Yu H Y. Convolutional neural network based metal artifact reduction in X-ray computed tomography[J]. IEEE Transactions on Medical Imaging, 37, 1370-1381(2018).

    [2] Pechstein T. Industrielle röntgen-computer to mographie[J]. tm-Technisches Messen, 87, 79-80(2020).

    [3] O'Brien N S. Boardman R P, Sinclair I, et al. Recentadvances in X-ray cone-beam computed laminography[J]. Journal of X-Ray Science and Technology, 24, 691-707(2016).

    [4] Chen Z, Liang J H, Zhang X M. Method and experiments on slice reconstruction of plate-like component based on X-ray laminography[J]. Computerized Tomography Theory and Applications, 23, 579-589(2014).

    [5] Zou J, Zeng W, Hu X D. New method based on combination of limited-angle and computed laminography imaging for plate-like objects[J]. Nanotechnology and Precision Engineering, 15, 366-371(2017).

    [6] Hsieh J[M]. Computed tomography principle, design, artifacts, and recent advances, 1(2006).

    [7] Plantes B G, Ziedses D. Eine neue methode zur differenzierung in der rontgenographie (planigraphies)[J]. Acta Radiologica, 13, 182-192(1932).

    [8] Blumensath T. O’Brien N, Wood C E. Calibration of robotic manipulator systems for cone-beam tomography imaging[J]. IEEE Transactions on Nuclear Science, 65, 1384-1393(2018).

    [9] Gao H, Zhang L, Chen Z et al. Direct filtered-backprojection-type reconstruction from a straight-line trajectory[J]. Optical Engineering, 46, 057003(2007).

    [10] Hoshino M, Uesugi K, Takeuchi A et al. Development of X-ray laminography under an X-ray microscopic condition[J]. The Review of Scientific Instruments, 82, 073706(2011).

    [11] Wood C E. O’Brien N, Denysov A, et al. Computed laminography of CFRP using an X-ray cone-beam and robotic sample manipulator systems[J]. IEEE Transactions on Nuclear Science, 66, 655-663(2019).

    [12] Voland V, Hoyer U, Auer R et al. Defect recognition in crystalline silicon solar cells by X-ray tomosynthesis with layer resolution[J]. Progress in Photovoltaics: Research and Applications, 23, 124-130(2015).

    [13] Lewitt R M, Matej S. Overview of methods for image reconstruction from projections in emission computed tomography[J]. Proceedings of the IEEE, 91, 1588-1611(2003).

    [14] Wei Z H, Yuan L L, Liu B D et al. A micro-CL system and its applications[J]. Review of Scientific Instruments, 88, 115107(2017).

    [15] Helfen L, Xu F, Schillinger B et al. Neutron laminography: a novel approach to three-dimensional imaging of flat objects with neutrons[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 651, 135-139(2011).

    [16] Wang S Y, Wu W W, Gong C C et al. Study of parallel translation computed laminography imaging[J]. Acta Optica Sinica, 38, 1211002(2018).

    [17] Que J M, Cao D Q, Zhao W et al. Computed laminography and reconstruction algorithm[J]. Chinese Physics C, 36, 777-783(2012).

    [18] Jimenez-Mendoza D. Espinosa-Arbelaez D G, Giraldo-Betancur A L, et al. Single X-ray transmission system for bone mineral density determination[J]. Review of Scientific Instruments, 82, 125105(2011).

    Zhongjian Tian, Haijun Yu, Linbo Wang, Zhenzhen Pi, Fenglin Liu. Orthogonal Translation Computed Laminography[J]. Acta Optica Sinica, 2020, 40(22): 2211002
    Download Citation