• Spectroscopy and Spectral Analysis
  • Vol. 41, Issue 12, 3881 (2021)
Liang-xiao CHENG1、*, Jin-hua TAO1、1; *;, Hai-jin ZHOU3、3;, Chao YU1、1;, Meng FAN1、1;, Ya-peng WANG4、4;, Zhi-bao WANG5、5;, and Liang-fu CHEN1、1;
Author Affiliations
  • 11. State Key Laboratory of Remote Sensing Science, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing Normal University, Beijing 100101, China
  • 33. Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China 4. National Satellite Meteorological Center, China Meteorological Administration, Beijing 100081, China
  • 4[in Chinese]
  • 55. School of Computer and Information Technology, Northeast Petroleum University, Daqing 163318, China
  • show less
    DOI: 10.3964/j.issn.1000-0593(2021)12-3881-06 Cite this Article
    Liang-xiao CHENG, Jin-hua TAO, Hai-jin ZHOU, Chao YU, Meng FAN, Ya-peng WANG, Zhi-bao WANG, Liang-fu CHEN. Evaluations of Environmental Trace Gases Monitoring Instrument (EMI) Level 1 Data[J]. Spectroscopy and Spectral Analysis, 2021, 41(12): 3881 Copy Citation Text show less

    Abstract

    The Environmental trace gases Monitoring Instrument (EMI) is the first high spectral resolution imaging spectrometer in China designed to monitor trace gas in tropospheric and stratospheric. To fully understand the instrument’s characteristics and make better use of the level 1 (L1) data, comprehensive evaluations of irradiance and radiance data measured by the EMI instrument were carried out in this study. For both ultraviolet-2 and visible-1 bands,the slit function change drastically as a function of detectors in the across-track direction of charge-coupled device (CCD), which is more than 6 times larger than that of TROP(OMI). The use of different slit functions according to the row can improve the calibration accuracy. Small wavelength shifts were found in both irradiance and radiance data with an average value of 0.015 and 0.03 nm, respectively. Although they meet the requirement of the design specification (0.05 nm), wavelength calibration is still needed during the trace gas retrieval. EMI irradiance data agree highly (r>0.95) with OMI and TROPOMI and the reference solar spectrum. EMI radiance data also shows a better agreement (r>0.93) with OMI and TROPOMI by averaging the cloud-free pixels over the clean Pacific region. This study demonstrates the good quality of current EMI L1 data for trace gas retrieval, and it provides a reference for the design and data quality evaluation scheme of subsequent instruments.