• Acta Optica Sinica
  • Vol. 39, Issue 10, 1011002 (2019)
Xianglei Song1, Shu Li2, Mengtao Gu1, Biao Zhang1, and Chuanlong Xu1、*
Author Affiliations
  • 1Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing, Jiangsu 210096, China
  • 2Department of Science and Technology Development, Nanjing Institute of Measurement and Testing Technology, Nanjing, Jiangsu 210037, China
  • show less
    DOI: 10.3788/AOS201939.1011002 Cite this Article Set citation alerts
    Xianglei Song, Shu Li, Mengtao Gu, Biao Zhang, Chuanlong Xu. Three-Dimensional Reconstruction of Micro-Scale Flow Field Based on Light Field Microscopic Imaging[J]. Acta Optica Sinica, 2019, 39(10): 1011002 Copy Citation Text show less
    References

    [1] Rivet C, Lee H, Hirsch A et al. Microfluidics for medical diagnostics and biosensors[J]. Chemical Engineering Science, 66, 1490-1507(2011). http://www.sciencedirect.com/science/article/pii/S0009250910004823

    [2] Michelsen U. Microfluidics in medical applications[J]. Medical Device Technology, 18, 12-14(2007).

    [3] Horrocks M H, Tosatto L, Dear A J et al. Fast flow microfluidics and single-molecule fluorescence for the rapid characterization of α-synuclein oligomers[J]. Analytical Chemistry, 87, 8818-8826(2015). http://pubs.acs.org/doi/abs/10.1021/acs.analchem.5b01811

    [4] Wang G L, Yang D W, Wang Y et al. Heat transfer and friction characteristics of the microfluidic heat sink with variously-shaped ribs for chip cooling[J]. Sensors, 15, 9547-9562(2015). http://europepmc.org/articles/PMC4431240

    [5] Santiago J G, Wereley S T, Meinhart C D et al. A particle image velocimetry system for microfluidics[J]. Experiments in Fluids, 25, 316-319(1998). http://onlinelibrary.wiley.com/resolve/reference/XREF?id=10.1007/s003480050235

    [6] Chao S H, Holl M R, Koschwanez J H et al. Velocity measurement in microchannels with a laser confocal microscope and particle linear image velocimetry[J]. Microfluidics and Nanofluidics, 1, 155-160(2005). http://link.springer.com/article/10.1007/s10404-004-0023-6

    [7] Lindken R, Westerweel J, Wieneke B. Stereoscopic micro particle image velocimetry[J]. Experiments in Fluids, 41, 161-171(2006). http://link.springer.com/article/10.1007/s00348-006-0154-5

    [8] Tien W H, Dabiri D, Hove J R. Color-coded three-dimensional micro particle tracking velocimetry and application to micro backward-facing step flows[J]. Experiments in Fluids, 55, 1684(2014). http://link.springer.com/article/10.1007/s00348-014-1684-x

    [9] Ren N, Levoy M, Bredif M et al. 2019-03-25]. http: ∥graphics.stanford.edu/papers/lfcamera/.(2005).

    [10] Levoy M, Ng R, Adams A et al. Light field microscopy[J]. ACM Transactions on Graphics, 25, 924-934(2006).

    [11] Sun F S, Han X. Super-resolution algorithm based on precise color vector constraint of lightfield camera[J]. Acta Optica Sinica, 39, 0301001(2019).

    [12] Shi S X, Ding J F, New T H et al. Light-field camera-based 3D volumetric particle image velocimetry with dense ray tracing reconstruction technique[J]. Experiments in Fluids, 58, 78(2017). http://link.springer.com/10.1007/s00348-017-2365-3

    [13] Fahringer T W, Lynch K P, Thurow B S. Volumetric particle image velocimetry with a single plenoptic camera[J]. Measurement Science and Technology, 26, 115201(2015). http://www.ingentaconnect.com/content/iop/mst/2015/00000026/00000011/art115201

    [14] Gershun A. The light field[M]. Massachusetts, Cambridge: Massachusetts Institute of Technology, 51-151(1939).

    [15] Levoy M, Hanrahan P. Light field rendering. [C]∥The 23rd Annual Conference on Computer Graphics and Interactive Techniques. New York: ACM, 31-42(1996).

    [16] Sarder P, Nehorai A. Deconvolution methods for 3-D fluorescence microscopy images[J]. IEEE Signal Processing Magazine, 23, 32-45(2006). http://ieeexplore.ieee.org/xpls/icp.jsp?arnumber=1628876

    [17] McNally J G, Karpova T, Cooper J et al. . Three-dimensional imaging by deconvolution microscopy[J]. Methods, 19, 373-385(1999). http://www.sciencedirect.com/science/article/pii/S1046202399908733

    [18] Lucy L B. An iterative technique for the rectification of observed distributions[J]. The Astronomical Journal, 79, 745-754(1974). http://gji.oxfordjournals.org/external-ref?access_num=10.1086/111605&link_type=DOI

    [19] Richardson W H. Bayesian-based iterative method of image restoration[J]. Journal of the Optical Society of America, 62, 55-59(1972). http://icesjms.oxfordjournals.org/external-ref?access_num=10.1364/JOSA.62.000055&link_type=DOI

    [20] Gu M. Advanced optical imaging theory[M]. Berlin, Heidelberg: Springer, 55-59(2000).

    [21] Wang Z, Bovik A C, Sheikh H R et al. Image quality assessment: from error visibility to structural similarity[J]. IEEE Transactions on Image Processing, 13, 600-612(2004). http://jamia.bmj.com/external-ref?access_num=10.1109/TIP.2003.819861&link_type=DOI

    [22] Liang Q T[M]. Physical optics, 173-175(2012).

    [23] Deem E A, Zhang Y, Cattafesta L N et al. On the resolution of plenoptic PIV[J]. Measurement Science and Technology, 27, 084003(2016). http://adsabs.harvard.edu/abs/2016MeScT..27h4003D

    Xianglei Song, Shu Li, Mengtao Gu, Biao Zhang, Chuanlong Xu. Three-Dimensional Reconstruction of Micro-Scale Flow Field Based on Light Field Microscopic Imaging[J]. Acta Optica Sinica, 2019, 39(10): 1011002
    Download Citation