• Acta Optica Sinica
  • Vol. 41, Issue 18, 1812001 (2021)
Min Fu1、*, Fan Chen1、2, Ge Zhu2, Hailin Shi1、2, Xiaobo Wei1、2, Junhong Qiao1、2, and Congyang Leng1、2
Author Affiliations
  • 1Engineering Research Center of Mechanical Testing Technology and Equipment (Ministry of Education), Chongqing Key Laboratory of Time-Grating Sensing and Advanced Testing Technology, Chongqing University of Technology, Chongqing 400054, China
  • 2College of Mechanical Engineering, Chongqing University of Technology, Chongqing 400054, China
  • show less
    DOI: 10.3788/AOS202141.1812001 Cite this Article Set citation alerts
    Min Fu, Fan Chen, Ge Zhu, Hailin Shi, Xiaobo Wei, Junhong Qiao, Congyang Leng. High-Precision Angular Displacement Measurement Based on Rotating Optical Field[J]. Acta Optica Sinica, 2021, 41(18): 1812001 Copy Citation Text show less
    References

    [1] Yu H, Wan Q H, Sun Y et al. A high precision image angular displacement measurement device with self-adaptive installation[J]. Chinese Optics, 13, 510-516(2020).

    [2] Xu B, Lei B, Fan C C et al. Internal error compensation method based on high-frequency angular displacement for high-resolution optical satellite images[J]. Acta Optica Sinica, 36, 0928002(2016).

    [3] Zhai Z S, Cheng Z, Zhang Y H et al. Optical analysis of moiré fringes of concentric-circle gratings[J]. Laser & Optoelectronics Progress, 55, 070501(2018).

    [4] Zhang W Y, Zhu H R, Li M X et al. Real-time in situ calibration for angle measuring sensor based on autocollimator[J]. Chinese Journal of Lasers, 46, 0404005(2019).

    [5] Zhu G, Pu Z W, Fu M et al. Measurement method for micro-controlled phase-shifting precise linear displacement of single-alternating light field[J]. Acta Optica Sinica, 40, 0212001(2020).

    [6] Feng Y Q, Wan Q H, Sun Y et al. Interpolation error correction of moiré fringe photoelectric signals in the approximate form of triangle wave[J]. Acta Optica Sinica, 33, 0812001(2013).

    [7] Zhu J P, Hu S, Yu J S et al. Theoretical analysis of photolithography alignment and calibration method based on moiré fringes[J]. Acta Optica Sinica, 32, 0607001(2012).

    [8] Zhu F, Wu Y M, Liu C C. Eliminating influence of grating encoder’s eccentricity and vibration to moiré fringes signal by four reading heads[J]. Acta Optica Sinica, 31, 0412008(2011).

    [9] Zhang W Y, Lao D B, Zhou W H et al. Self-calibration method based on multi-head reading layout[J]. Acta Optica Sinica, 38, 0812001(2018).

    [10] Feng C P, Zhu L Q, Pan Z K et al. New self-calibration method of circular grating eccentric parameters[J]. Chinese Journal of Scientific Instrument, 37, 2459-2464(2016).

    [11] Zhang W Y, Lao D B, Zhou W H et al. Suppression method for angle measurement error of mixing-layout multiple reading head[J]. Optics and Precision Engineering, 25, 2339-2346(2017).

    [12] Ren X, Du S P, Chen K et al. Error source and spectrum analysis for angle measurement of circular grating encoder[J]. Laser & Optoelectronics Progress, 57, 171205(2020).

    [13] Zhang J J, Zhang Z Y, Liu J C. Novel method of calibrating the angle-measurement error of resolver[J]. Chinese Journal of Scientific Instrument, 31, 149-153(2010).

    [14] Shang J, Wang H, Liu C J et al. Design and magnetic principle analysis of one kind of dual channels total magnetic coarse-exact reluctance resolver[J]. Proceedings of the CSEE, 37, 3938-3944(2017).

    [15] Bahari M, Davoodi A, Saneie H et al. A new variable reluctance PM-resolver[J]. IEEE Sensors Journal, 20, 135-142(2020).

    [16] Jiao Y, Dong Z G, Ding Y et al. Optimal arrangements of scanning heads for self-calibration of angle encoders[J]. Measurement Science and Technology, 28, 105013(2017).

    [17] Hajmohammadi S, Alipour-Sarabi R, Nasiri-Gheidari Z et al. Influence of different installation configurations on the position error of a multiturn wound-rotor resolver[J]. IEEE Sensors Journal, 20, 5785-5792(2020).

    [18] Fu M, Zhang S Y, Zhu G et al. Study of a high-precision displacement sensor based on a configured moving light field with uniform scanning[J]. Measurement Science and Technology, 31, 075105(2020).

    [19] Peng D L, Fu M, Zhu G et al. Study on a novel linear displacement sensor based on the orthogonal modulating light intensity[J]. Acta Optica Sinica, 34, 1212007(2014).

    [20] Chen Z R, Zhao J, Tian W et al. Measurement error analysis and system design for the excitation signals of high-precision magnetic-field time-grating sensors[J]. Chinese Journal of Sensors and Actuators, 31, 1527-1534(2018).

    Min Fu, Fan Chen, Ge Zhu, Hailin Shi, Xiaobo Wei, Junhong Qiao, Congyang Leng. High-Precision Angular Displacement Measurement Based on Rotating Optical Field[J]. Acta Optica Sinica, 2021, 41(18): 1812001
    Download Citation