• Acta Optica Sinica
  • Vol. 30, Issue 6, 1651 (2010)
Tang Yuanhe*, GuoTing, and Gao Haiyang
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos20103006.1651 Cite this Article Set citation alerts
    Tang Yuanhe, GuoTing, Gao Haiyang. Modulation Transfer Function of Modified Sagnac Imaging Interferometer[J]. Acta Optica Sinica, 2010, 30(6): 1651 Copy Citation Text show less
    References

    [1] G. G. Shepherd,G. Thullier,W. A. Gault et al.. WINDII,the wind imaging interferometer on the upper atmosphere research satellite [J]. J. Geophys. Res.,1993,98(D6):10723-10750

    [2] G. G. Shepherd,I. C. McDade,W. A. Gault et al.. The stratospheric wind interferometer for transport studies (swift) [J]. Adv. Space Res.,2001,27(6-7):1071-1079

    [3] William Gault,Ian McDade,Yves J. Rochon et al.. Filters and calibration for the SWIFT instrument on GCOM-A1 [C]. SPIE,2003,4881:60-66

    [4] Y. J. Rochon,P. Rahnama,I. C. McDade et al.. Data retrieval and error analysis study on the measurement of stratospheric winds with a Michelson interferometer [J]. SPIE,2004,5234:333-346

    [5] J. C. Bird,F. C. Liang,B. H. Solheim et al.. A polarizing Michelson interferometer for measuring thermospheric winds[J]. Meas. Sci. Technol.,1995,6:1368-1378

    [6] W. A. Gault,S. Sargoytchev,S. Brown. Divided mirror technique for measuring doppler shifts with a Michelson interferometer[C]. SPIE,2001,4306:266-272

    [7] Yuanhe Tang,Guangde Chen,Chunmin Zhang et al.. Optimization of a super-widen-angle modified Sagnac interferometer [C]. SPIE,6279:62791G-1-6

    [8] Ye Jianyong,Zhang Chunmin,Zhao Baochang et al.. Study of optical path difference and detection mode of a Sagnac interferometer used for upper atmospheric detection[J]. Acta Optica Sinica,2007,27(7):1145-1150

    [9] Tang Yuanhe,Chen Guangde,Zhao Zhenyu et al.. Optical throughput of modified Sagnac imaging interferometer[J]. Acta Optica Sinica,2007,27(8):1490-1493

    [10] Tang Yuanhe,Zhang Chunmin,He Jian et al.. Study of the detection mode of upper atmospheric wind field based on lorentzian profile aurora[J]. Acta Optica Sinica,2005,25(6):721-725

    [11] Tang Yuanhe,Zhang Chunmin,Chen Guangde et al.. Measurement atmospheric wind field with wide-angle modified Sagnac interferometer by satellite′s pushbroom mode[J] . Progress in Nature Science,2006,16(11):1491-1495

    CLP Journals

    [1] Zhang Xinxin, Jiang Hongbin, Li Zhengbin. Building of Simulation Environment for Sagnac Effect in Rotating Reference Frame[J]. Laser & Optoelectronics Progress, 2013, 50(10): 101402

    [2] Wanxia Li, Qipeng Lu, Yuan Song, Xinyang Yu. Reflective Static Fourier Spectrometer Optical System Based on Double Right-Angle Beam Splitter[J]. Acta Optica Sinica, 2017, 37(8): 0812004

    Tang Yuanhe, GuoTing, Gao Haiyang. Modulation Transfer Function of Modified Sagnac Imaging Interferometer[J]. Acta Optica Sinica, 2010, 30(6): 1651
    Download Citation