[1] Withers P J, Bouman C, Carmignato S et al. X-ray computed tomography[J]. Nature Reviews Methods Primers, 1, 18(2021).
[2] Vásárhelyi L, Kónya Z, Kukovecz Á et al. Microcomputed tomography‒based characterization of advanced materials: a review[J]. Materials Today Advances, 8, 100084(2020).
[3] du Plessis A, Yadroitsev I, Yadroitsava I et al. X-ray microcomputed tomography in additive manufacturing: a review of the current technology and applications[J]. 3D Printing and Additive Manufacturing, 5, 227-247(2018).
[4] Liu H X, Zhao Y M, Zhang C L et al. Study on tooth cone beam CT image reconstruction based on improved U-net network[J]. Chinese Journal of Lasers, 49, 2407207(2022).
[5] Di J L, Lin J C, Zhong L Y et al. Review of sparse-view or limited-angle CT reconstruction based on deep learning[J]. Laser & Optoelectronics Progress, 60, 0811002(2023).
[6] du Plessis A, le Roux S G, Guelpa A. Comparison of medical and industrial X-ray computed tomography for non-destructive testing[J]. Case Studies in Nondestructive Testing and Evaluation, 6, 17-25(2016).
[7] Ge W J, Yu H J, Chen J et al. Analytical reconstruction for source translation scanning computed tomography based on derivative-Hilbert transform-back projection[J]. Acta Optica Sinica, 42, 1134025(2022).
[8] Shi Y Y, Wang Z B, Jin Y. CT technology for solid rocket motor detachment[J]. Journal of Projectiles, Rockets, Missiles and Guidance, 26, 928-929, 933(2006).
[9] Chen Q G, Lu H Y, Qi Q et al. Tangential CT inspection of interface debonding of SRM[J]. Journal of Solid Rocket Technology, 39, 347-352(2016).
[10] Zeng L, Liu B D, Liu L H et al. A new iterative reconstruction algorithm for 2D exterior fan-beam CT[J]. Journal of X-Ray Science and Technology, 18, 267-277(2010).
[11] Riis N B, Frøsig J, Dong Y et al. Limited-data X-ray CT for underwater pipeline inspection[J]. Inverse Problems, 34, 034002(2018).
[12] Chen C Y, Gao H W, Zhang T et al. Progress on analytical CT reconstruction methods: from circular trajectory scanning to multi-source linear trajectory scanning imaging[J]. Computerized Tomography Theory and Applications, 30, 263-277(2021).
[13] Liu B D, Zeng L. Parallel SART algorithm of linear scan cone-beam CT for fixed pipeline[J]. Journal of X-Ray Science and Technology, 17, 221-232(2009).
[14] Schön T, Fuchs T, Hanke R et al. A translation-based data acquisition method for computed tomography: theoretical analysis and simulation study[J]. Medical Physics, 40, 081922(2013).
[15] Liu F L, Yu H Y, Cong W X et al. Top-level design and pilot analysis of low-end CT scanners based on linear scanning for developing countries[J]. Journal of X-Ray Science and Technology, 22, 673-686(2014).
[16] Zhang T, Xing Y X, Zhang L et al. Stationary computed tomography with source and detector in linear symmetric geometry: direct filtered backprojection reconstruction[J]. Medical Physics, 47, 2222-2236(2020).
[17] Yu H J, Li L, Tan C D et al. X-ray source translation based computed tomography (STCT)[J]. Optics Express, 29, 19743-19758(2021).
[18] Liao M J, Li L, Duan X J et al. Local source-translation CT imaging for testing in-service high-voltage cables[J]. Acta Optica Sinica, 42, 1611002(2022).
[19] Li L, Yu H J, Tan C D et al. Analytical reconstruction algorithm of source translation based CT[J]. Chinese Journal of Scientific Instrument, 43, 187-195(2022).
[20] Yu H J, Ni S, Chen J et al. Analytical reconstruction algorithm for multiple source-translation computed tomography (mSTCT)[J]. Applied Mathematical Modelling, 117, 251-266(2023).
[21] Chen J, Yu H J, Ni S et al. Weighted filtered back-projection for source translation computed tomography reconstruction[J]. IEEE Transactions on Instrumentation and Measurement, 72, 4506409(2023).
[22] Chetih N, Messali Z. Tomographic image reconstruction using filtered back projection (FBP) and algebraic reconstruction technique (ART)[C]. Algeria, 25-27(2015).
[23] Andersen A H, Kak A C. Simultaneous Algebraic Reconstruction Technique (SART): a superior implementation of the ART algorithm[J]. Ultrasonic Imaging, 6, 81-94(1984).
[24] Gregor J, Benson T. Computational analysis and improvement of SIRT[J]. IEEE Transactions on Medical Imaging, 27, 918-924(2008).
[25] Huang L Y, Zhu S P, Kuang T[M]. Simulation experiment of medical image reconstruction(2015).
[26] van Aarle W, Palenstijn W J, Cant J et al. Fast and flexible X-ray tomography using the ASTRA toolbox[J]. Optics Express, 24, 25129-25147(2016).
[27] Chai T, Draxler R R. Root mean square error (RMSE) or mean absolute error (MAE)? ‒Arguments against avoiding RMSE in the literature[J]. Geoscientific Model Development, 7, 1247-1250(2014).
[28] Sheikh H R, Bovik A C, de Veciana G. An information fidelity criterion for image quality assessment using natural scene statistics[J]. IEEE Transactions on Image Processing, 14, 2117-2128(2005).
[29] Wang Z, Bovik A C, Sheikh H R et al. Image quality assessment: from error visibility to structural similarity[J]. IEEE Transactions on Image Processing, 13, 600-612(2004).
[30] Quinto E T. Artifacts and visible singularities in limited data X-ray tomography[J]. Sensing and Imaging, 18, 9(2017).