• Laser & Optoelectronics Progress
  • Vol. 51, Issue 11, 111202 (2014)
Li Xiaojie1、2、*, Ren Jianwei1, Liu Hongxing1, and Wan Zhi1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/lop51.111202 Cite this Article Set citation alerts
    Li Xiaojie, Ren Jianwei, Liu Hongxing, Wan Zhi. Spectral Response Testing and Uncertainty Evaluation of Plane Array CCD[J]. Laser & Optoelectronics Progress, 2014, 51(11): 111202 Copy Citation Text show less
    References

    [1] Li Zhaohui, Wang Zhaoxun, Wu Keyong. Optical assembly of CCD focal plane for space camera [J]. Optics and Precision Engineering, 2000, 8(3): 213-216.

    [2] Shen Honghai, Huang Meng, Li Jiaquan, et al.. Recent progress in aerial electro- optic payloads and their key technologies [J]. Chinese Optics, 2012, 5(1): 20-29.

    [3] Ye Zhao, Liu Zexun, Li Xiansheng, et al.. Screening device of CCD spectral conformance for wide field of view space camera [J]. Journal of Optoelectronics·Laser, 2013, 24(2): 265-270.

    [4] Li Yudong, Wang Bo, Guo Qi, et al.. Testing system for radiation effects of CCD and CMOS image sensors [J]. Optics and Precision Engineering, 2013, 21(11): 2778-2784.

    [5] Jin Hui, Jiang Huilin, Zheng Yuquan, et al.. Spectral calibration of the hyperspectral optical remote sensor [J]. Chinese J Luminescence, 2013, 34(2): 235-239.

    [6] Liu Yanyan, Li Guoning, Yang Xiaohui, et al.. High-precision detection of wide-band spectral responsivity of TDI CCD [J]. Semiconductor Optoelectronics, 2013, 34(2): 298-300.

    [7] Alejandro Ferrero, Joaquin Campos, Alicia Pons. Low- uncertainty absolute radiometric calibration of a CCD [J]. Metrologia, 2006, 43(2): 17-21.

    [8] Yan Feng, Zhou Yue, Zhang Mingchao, et al.. Test equipment for relative spectral response of CCD [J]. Spectroscopy and Spectral Analysis, 2013, 33(10): 2865-2868.

    [9] Liu Hongxing, Ren Jianwei, Wan Zhi, et al.. Measurement of relative spectral responsivity of photodetector by LEDbased spectrum-tunable source [J]. Spectroscopy and Spectral Analysis, 2013, 33(1): 250-254.

    [10] Zou Peng, Zheng Xiaobing, Wu Haoyu, et al.. Research on calibration of radiance detector based on trap detector [J]. Acta Optica Sinica, 2013, 33(7): 0712002.

    [11] Ma Liang, Wei Jun, Huang Xiaoxian, et al.. Laboratory spectral calibration method of grating dispersive imaging spectrometer [J]. Laser & Optoelectronics Progress, 2013, 50(2): 023001.

    [12] Liu Dongmei, Xia Rihui, Pan Yonggang, et al.. Study of digital spectrometer based on change coupled device [J]. Acta Optica Sinica, 2012, 32(1): 0107003.

    [13] Zhang Zhenduo, Wang Shurong, Li Hongzhuang, et al.. Study on calibration environment of spectral responsivity for space ultraviolet remote sensing instrument [J]. Acta Optica Sinica, 2012, 32(3): 0312001.

    CLP Journals

    [1] CHEN Xue, LI Zongxuan, YAN Feng, ZHANG Mingchao, ZHOU Yue, SUI Yongxin. Test System for Absolute Spectral Response of SBUV Image Intensifier[J]. Opto-Electronic Engineering, 2016, 43(5): 8

    [2] Shiming Xiang, Xuewu Fan, Na He, Zhe Bai. Review on Low Light Level Remote Sensing Imaging Technology[J]. Laser & Optoelectronics Progress, 2018, 55(2): 020009

    [3] Sun Hui, Xu Shuyan, Sun Shouhong, Li Junlin. Research on Evaluation Method of Optical Imaging Sensors’Photon Response Non-Uniformity Noise[J]. Laser & Optoelectronics Progress, 2015, 52(4): 42302

    [4] Zhang Yuanzhi, Pan Liang, Wang Yikun, Hou Huayi, Zhu Ling, Wang An, Liu Yong. Calibration for Tissue Fluorescence Spectroscopy System[J]. Laser & Optoelectronics Progress, 2015, 52(8): 81701

    Li Xiaojie, Ren Jianwei, Liu Hongxing, Wan Zhi. Spectral Response Testing and Uncertainty Evaluation of Plane Array CCD[J]. Laser & Optoelectronics Progress, 2014, 51(11): 111202
    Download Citation