• Acta Optica Sinica
  • Vol. 31, Issue 12, 1211001 (2011)
Kong Ningning1、2、3、*, Li Chao1、2、3, Xia Mingliang1、2、3, Qi Yue1、2、3, Li Dayu2, and Xuan Li1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: 10.3788/aos201131.1211001 Cite this Article Set citation alerts
    Kong Ningning, Li Chao, Xia Mingliang, Qi Yue, Li Dayu, Xuan Li. Research on Flat Field Correction Method in Adaptive Optics Retinal Imaging System[J]. Acta Optica Sinica, 2011, 31(12): 1211001 Copy Citation Text show less
    References

    [1] R. S. Jonnal, J. R. Besecker, J. C. Derby et al.. Imaging outer segment renewal in living human cone photoreceptors[J]. Opt. Express, 2010, 18(5): 5257~5270

    [2] Y. Kitaguchi, T. Fujikado, K. Bessho et al.. Adaptive optics fundus camera to examine localized changes in the photoreceptor layer of the fovea[J]. Ophthalmology, 2008, 115(10): 1771~1777

    [3] Z. Zhong, B. L. Petrig, X. Qi et al.. In vivo measurement of erythrocyte velocity and retinal blood flow using adaptive optics scanning laser ophthalmoscopy[J]. Opt. Express, 2008, 16(17): 12746~12756

    [4] J. Liang, B. Grimm, S. Goelz et al.. Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor[J]. J. Opt. Soc. Am. A, 1994, 11(7): 1949~1957

    [5] J. Liang, D. R. Williams, D. T. Miller. Supernormal vision and high-resolution retinal imaging through adaptive optics[J]. J. Opt. Soc. Am. A, 1997, 14(11): 2884~2892

    [6] Li Bangming, Liao Wenhe, Shen Jianxin et al.. Wavefront control algorithm research on micromachined membrane deformable mirror in the human eye aberration correction[J]. Acta Optica Sinica, 2010, 30(4): 917~921

    [7] A. Roorda, F. Romero-Borja, W. J. Donnelly et al.. Adaptive optics scanning laser ophthalmoscopy[J]. Opt. Express, 2002, 10(9): 405~412

    [8] Cheng Shaoyun, Hu Lifa, Cao Zhaoliang et al.. Application of liquid crystal adaptive optics system on human eye fundus imaging with high spatial resolution[J]. Chin. J. Lasers, 2009, 36(10): 2524~2527

    [9] F. C. Delori, K. P. Pflibsen. Spectral reflectance of the human ocular fundus[J]. App. Opt., 1989, 28(6): 1061~1077

    [10] Li Chao, Xia Mingliang, Mu Quanquan et al.. Laser speckle reduction in retina imaging illuminetion[J]. Acta Optica Sinica, 2008, 28(12): 2245~2249

    [11] Jiang Xiaoguo, Wang Yuan, Zhang Kaizhi et al.. Calibration method for non-uniformity between multiple images from a high-speed multi-frame CCD camera[J]. Acta Optica Sinica, 2006, 26(4): 531~535

    [12] Topfer Karin, Dehority John. Optimized operation and offset corrections for a battery-powered wireless digital X-ray detector[C]. SPIE, 2009, 7258: 72583O1~72583O8

    [13] Dou Changyong, Zhang Xiaodong, Doug Olsen et al.. Flat field correction for AgCam[J]. Periodical of Ocean University of China, 2010, 40(9): 137~141

    [14] Lee Hyoung Koo, Kim Do Il, Kim Sung Hyeon et al.. An iterative method for flat-field correction of digital radiography when detector is at any position[C]. SPIE, 2005, 5745: 1025~1029

    [15] Yang Junwei, Hu Zhongxiang, Shi Xiaojun et al.. Error analysis of on-line temperature-field measurement by infrated CCD[J]. Acta Optica Sinica, 2009, 29(5): 1281~1284

    [16] Song Zongxi, Zhao Baochang, Gao Wei et al.. Focal plane design of Chang′e-1 satellite CCD stereo-camera and laboratory radiation calibration[J]. Acta Optica Sinica, 2010, 30(12): 3508~3514

    [17] Liu Jun, Zhao Jibin, Liu Weijun et al.. Gene chip microarray fluorescent spots images CCD scanning and acquiring system[J]. Chin. J. Lasers, 2010, 37(2): 505~509

    [18] Liang Zhu. Principle of Optics[M]. Beijing: Beihang University Press, 2005. 107~111

    [19] Ding Xiaohua, Li You, Yu Qifeng et al.. CCD noise calibration and its application in edge location[J]. Acta Optica Sinica, 2008, 28(1): 99~104

    [20] C. Li, M. Xia, D. Li et al.. High-resolution retinal imaging through open-loop adaptive optics[J]. J. Biomed. Opt., 2010, 15(4): 046009-1~046009-6

    [21] C. Li, M. Xia, Q. Mu et al.. High-precision open-loop adaptive optics system based on LC-SLM[J]. Opt. Express, 2009, 17(13): 10774~10781

    [22] Q. Mu, Z. Cao, D. Li et al.. Open-loop correction of horizontal turbulence: system design and result[J]. Appl. Opt., 2008, 47(23): 4297~4301

    [23] ANSI, American National Standard for the Safe Use of Lasers[S]. ANSI Z136.1-2007, Laser Institute of America, Orlando, FL (2007)

    [24] P. M. Prieto, F. V. Martin, J. S. McLellan et al.. Effect of the polarization on ocular wave aberration measurements[J]. J. Opt. Soc. Am. A, 2002, 19(4): 809~814

    [25] Heidi Hofer, Pablo Artal, Ben Singer et al.. Dynamics of the eye′s wave aberration[J]. J. Opt. Soc. Am. A, 2001, 18(3): 497~506

    [26] Thomas Nirmaier, Gopal Pudasaini, Josef Bille. Very fast wave-front measurements at the human eye with a custom CMOS-based Hartmann-Shack sensor[J]. Opt. Express, 2003, 11(21): 2704~2716

    [27] Curtis R. Vogel, David W. Arathom, Austin Roorda et al.. Retinal motion estimation in adaptive optics scanning laser opthalmoscopy[J]. Opt. Express, 2006, 14(2): 487~497

    [28] J. Rha, R. S. Jonnal, K. E. Thorn et al.. Adaptive optics flood-illumination camera for high speed retinal imaging[J]. Opt. Express, 2006, 14(10): 4552~4569

    CLP Journals

    [1] Jiang Huilü, Liao Na, Li Chaohong, Li Yiyu, Chen Hao, Huang Jinhai, Wang Qinmei. High-Speed Compact Adaptive Optics Scanning Laser Ophthalmoscope[J]. Acta Optica Sinica, 2015, 35(11): 1117002

    [2] Qi Yue, Kong Ningning, Li Dayu, Xia Mingliang, Xuan Li. High Resolution Open-Loop Adaptive Optics System for Retinal Imaging Based on Liquid Crystal Spatial Light Modulator[J]. Acta Optica Sinica, 2012, 32(10): 1011003

    Kong Ningning, Li Chao, Xia Mingliang, Qi Yue, Li Dayu, Xuan Li. Research on Flat Field Correction Method in Adaptive Optics Retinal Imaging System[J]. Acta Optica Sinica, 2011, 31(12): 1211001
    Download Citation