• Acta Optica Sinica
  • Vol. 41, Issue 3, 0322001 (2021)
Longhui Li1, Chen Zhang2、3、*, Ge Jin1, Weimin Yuan2、3, Zhen Li1, Yan Gu1, Zhen Zhang1, Zhao Xu1, Bowen Jiang1, Yidai Liao1, Chao Wu1, Yufei Li1, Yan Guo1, Tian Qin1, Zhixing Ling2、3, and Donghua Zhao2、3
Author Affiliations
  • 1North Night Vision Technology Co., Ltd., Nanjing, Jiangsu 211106, China
  • 2National Astronomical Observatories, Chinese Academy of Sciences, Key Laboratory of Space Astronomy and Technology, Chinese Academy of Sciences, Beijing 100012, China
  • 3College of Astronomy and Space Science, University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.3788/AOS202141.0322001 Cite this Article Set citation alerts
    Longhui Li, Chen Zhang, Ge Jin, Weimin Yuan, Zhen Li, Yan Gu, Zhen Zhang, Zhao Xu, Bowen Jiang, Yidai Liao, Chao Wu, Yufei Li, Yan Guo, Tian Qin, Zhixing Ling, Donghua Zhao. Test and Analysis of Micropore Statistical Characteristics of Angel Type Planar Lobster Eye Optical Device[J]. Acta Optica Sinica, 2021, 41(3): 0322001 Copy Citation Text show less

    Abstract

    In order to study the influence of micropore statistical characteristics of Angel type planar lobster optical devices on the focused imaging performance, a set of point-to-point vacuum X-ray beam test devices was developed in this work. The micro focal spot X-ray beam was used to carry out the focused imaging test on the developed optical device. The knife slit system was used to conduct two-dimensional scanning test on the planar lobster eye optical device. Different degrees of tilt-type process defects were found in different areas of the optical device. The effect of tilt process defects on focused imaging was simulated based on the Monte Carlo software. Experimental results show that the plane lobster eye optical devices used in the experiment can converge the incident X-ray beam into a clear cross image at a focal length of 3650 mm, the maximum full width at half maximum of the focal spot is about 4.63 mm, the corresponding largest angular resolution is about 4.36', and the unevenness of the point spread function is about 33.7%. Simulation results show that tilt-type process defects will decrease the intensity of the central bright spot, the crosshairs are diffuse and discontinuous, the secondary focal spot is distorted, and the image quality is deteriorated.
    Longhui Li, Chen Zhang, Ge Jin, Weimin Yuan, Zhen Li, Yan Gu, Zhen Zhang, Zhao Xu, Bowen Jiang, Yidai Liao, Chao Wu, Yufei Li, Yan Guo, Tian Qin, Zhixing Ling, Donghua Zhao. Test and Analysis of Micropore Statistical Characteristics of Angel Type Planar Lobster Eye Optical Device[J]. Acta Optica Sinica, 2021, 41(3): 0322001
    Download Citation