• Acta Physica Sinica
  • Vol. 69, Issue 3, 030601-1 (2020)
Zheng-Qiong Dong1, Hang Zhao1, Jin-Long Zhu2, and Ya-Ting Shi2、*
Author Affiliations
  • 1Hubei Key Laboratory of Manufacture Quality Engineering, Hubei University of Technology, Wuhan 430068, China
  • 2State Key Laboratory for Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
  • show less
    DOI: 10.7498/aps.69.20191525 Cite this Article
    Zheng-Qiong Dong, Hang Zhao, Jin-Long Zhu, Ya-Ting Shi. Influence of incident illumination on optical scattering measurement of typical photoresist nanostructure[J]. Acta Physica Sinica, 2020, 69(3): 030601-1 Copy Citation Text show less

    Abstract

    Optical scatterometry, as a fast, low-cost, and non-contact measurement instrument, is widely used in the profile characterization of nanostructure in the semiconductor manufacturing industry. In general, it involves two procedures, i.e. the forward optical modeling of sub-wavelength nanostructures and the reconstruction of structural profiles from the measured signatures. Here, the general term signature means the scattered light information from the diffractive grating structure, which can be in the form of reflectance, ellipsometric angles, Stokes vector elements, or Mueller matrix elements. The profile reconstruction process is an inverse problem with the objective of optimizing a set of floating profile parameters (e.g., critical dimension, sidewall angle, and height) whose theoretical signatures can best match the measured ones through regression analysis or library search.During solving the inverse problem, the refractive index and distinction coefficient of the material of nanostructure are assumed to be constants and they are generally fixed. This assumption is valid for most of the materials in semiconductor industry, but not for certain materials that are very photosensitive. That is, the optical constants of photosensitive materials may vary with the illumination time of the incident light beam in spectroscopic ellipsometer, and the error caused by the variation of optical constants propagates to the final extracted results of structural profiles, which should not be neglected, especially for high precision and accuracy metrology.Experiments performed on SiO2 and polymethyl methacrylate (PMMA) thin films are conducted and demonstrate that the extracted geometric parameters and optical constants of SiO2 film do not change with illumination time increasing, while the twenty groups of values of extracted refractive index n and distinction coefficient k of PMMA resist film vary obviously, and the difference between the extracted maximum and minimum film thickness has reached 40.5 nm, which to some extent illustrates that the above assumption is not valid for PMMA resist, so that the incident light beam of spectroscopic ellipsometer has a great influence on the extracted film thickness. Further, simulations based on a three-dimensional PMMA grating also indicate that the error of optical constant has considerably transferred to the extracted profile parameters. This finding is of significance for improving the accuracy of nanostructure characterization in optical scatterometry.
    Zheng-Qiong Dong, Hang Zhao, Jin-Long Zhu, Ya-Ting Shi. Influence of incident illumination on optical scattering measurement of typical photoresist nanostructure[J]. Acta Physica Sinica, 2020, 69(3): 030601-1
    Download Citation