• Laser & Optoelectronics Progress
  • Vol. 57, Issue 2, 21505 (2020)
Liu Jinyue, Wang Xiaoshuai, Li Yang, and Jia Xiaohui*
Author Affiliations
  • School of Mechanical Engineering, Hebei University of Technology, Tianjin 300132, China
  • show less
    DOI: 10.3788/LOP57.021505 Cite this Article Set citation alerts
    Liu Jinyue, Wang Xiaoshuai, Li Yang, Jia Xiaohui. Overall Fitting of Blade Contour Based on Tool Measurement Using Machine Vision[J]. Laser & Optoelectronics Progress, 2020, 57(2): 21505 Copy Citation Text show less
    Captured tool images.(a) LL-type; (b) LCL-type
    Fig. 1. Captured tool images.(a) LL-type; (b) LCL-type
    Ai versus k
    Fig. 2. Ai versus k
    Weighted value Sk versus k
    Fig. 3. Weighted value Sk versus k
    Curves of tool angle Ai. (a) LL-type tool vector angle; (b) LCL-type tool vector angle
    Fig. 4. Curves of tool angle Ai. (a) LL-type tool vector angle; (b) LCL-type tool vector angle
    Scatter plots of tool contour. (a) LL-type tool; (b) LCL-type tool
    Fig. 5. Scatter plots of tool contour. (a) LL-type tool; (b) LCL-type tool
    Contour scatter plots after rotation transformation of Fig. 5(b)
    Fig. 6. Contour scatter plots after rotation transformation of Fig. 5(b)
    Fitting results of slightly worn LL-type tool. (a) Piecewise fitting; (b) overall fitting
    Fig. 7. Fitting results of slightly worn LL-type tool. (a) Piecewise fitting; (b) overall fitting
    Fitting results of slightly worn LCL-type tool. (a) Piecewise fitting; (b) overall fitting
    Fig. 8. Fitting results of slightly worn LCL-type tool. (a) Piecewise fitting; (b) overall fitting
    Fitting results of severely worn LL-type tool. (a) Piecewise fitting; (b) overall fitting
    Fig. 10. Fitting results of severely worn LL-type tool. (a) Piecewise fitting; (b) overall fitting
    Fitting results of severely worn LCL-type tool. (a) Piecewise fitting; (b) overall fitting
    Fig. 11. Fitting results of severely worn LCL-type tool. (a) Piecewise fitting; (b) overall fitting
    Degreeof wearTool typeFitting methodStraight line 1Arc segmentStraight line 2Overall result
    NumberResidual /μmNumberResidual /μmNumberResidual /μmNumberResidual /μm
    SlightlywornType-LLPiecewise fitting7041.436661.7613701.59
    Overall fitting13701.57
    Type-LCLPiecewise fitting5265.773571.346403.4815133.79
    Overall fitting15133.73
    SeverelywornType-LLPiecewise fitting34813.75352162.4570088.52
    Overall fitting70062.67
    Type-LCLPiecewise fitting56977.4233427.83856116.27175986.91
    Overall fitting175967.35
    Table 1. Results of tool fitting residual
    Liu Jinyue, Wang Xiaoshuai, Li Yang, Jia Xiaohui. Overall Fitting of Blade Contour Based on Tool Measurement Using Machine Vision[J]. Laser & Optoelectronics Progress, 2020, 57(2): 21505