• Infrared and Laser Engineering
  • Vol. 44, Issue 6, 1878 (2015)
Wang Lan1, Sun Bo1, Long Changyu1, Zou Jian1、2, and Zhu Jigui1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: Cite this Article
    Wang Lan, Sun Bo, Long Changyu, Zou Jian, Zhu Jigui. A novel method for calibrating intrinsic parameters of linear array cameras based on collinear feature points[J]. Infrared and Laser Engineering, 2015, 44(6): 1878 Copy Citation Text show less
    References

    [1] Lim M S, Lim J. Visual measurement of pile movements for the foundation work using a high-speed line-scan camera[J]. Pattern Recognition, 2008, 41(6): 2025-2033.

    [2] Petty R S, Robinson M, Evans J P O. 3D measurement using rotating line-scan sensors[J]. Measurement Science and Technology, 1998, 9(3): 339.

    [3] Kataoka K, Osawa T, Ozawa S, et al. 3D building facade model reconstruction using parallel images acquired by line scan cameras[C]//IEEE International Conference on Image Processing, 2005, 1: I-1009-12.

    [4] Tsai R Y. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses[J]. Robotics and Automation, IEEE Journal of, 1987, 3(4): 323-344.

    [5] Liu Weiyi, Jia Jiqiang, Ding Yalin, et al. Measurement error impact on intrinsic parameters calibration in precise angle measurement method[J]. Infrared and Laser Engineering, 2009, 38(4): 705-709. (in Chinese)

    [6] Niu Haitao, Zhao Xunjie. New method of camera calibration based on checkerboard[J]. Infrared and Laser Engineering, 2011, 40(1): 133-137. (in Chinese)

    [7] Zhang Dan, Duan Jin, Gu Lingjia, et al. Method of camera calibration based on image processing[J]. Infrared and Laser Engineering, 2007, 36(S1): 561-565. (in Chinese)

    [8] Horaud R, Mohr R, Lorecki B. On single scanline camera calibration[J]. Robotics and Automation, IEEE Transactions On, 1993, 9(1): 71-75.

    [9] Luna C A, Mazo M, Lázaro J L, et al. Calibration of line-scan cameras[J]. Instrumentation and Measurement, IEEE Transactions on, 2010, 59(8): 2185-2190.

    [10] Draréni J, Roy S, Sturm P. Plane-based calibration for linear cameras[J]. International Journal of Computer Vision, 2011, 91(2): 146-156.

    [11] Hui B, Wen G, Zhao Z, et al. Line-scan camera calibration in close-range photogrammetry[J]. Optical Engineering, 2012, 51(5): 053602-1-053602-12.

    CLP Journals

    [1] Wenyi Chen, Jie Xu, Hui Yang. Camera calibration method based on double neural network[J]. Infrared and Laser Engineering, 2021, 50(11): 20210071

    [2] Yuxuan Chen, Zhongjun Qiu, Junjie Tang. Mechanical-imaging comprehensive error modeling in line scan vision detection systems[J]. Infrared and Laser Engineering, 2022, 51(12): 20220282

    [3] MA Wei-hong, TIAN Hui, DONG Tao, NI Jin-ping. Checkout of External Trigger Delay in Linear Image Acquisition System[J]. Acta Photonica Sinica, 2018, 47(9): 911002

    Wang Lan, Sun Bo, Long Changyu, Zou Jian, Zhu Jigui. A novel method for calibrating intrinsic parameters of linear array cameras based on collinear feature points[J]. Infrared and Laser Engineering, 2015, 44(6): 1878
    Download Citation