[1] Wen F. The study of framework of data acquisition system for lidar, 2-4(2013).
[2] Yan J X, Gong S S, Liu Z S. Environmental monitoring Lidar, 1-2(2001).
[3] Zhuang Q F, Wang Y M, Wang Z J et al. Typical case of multi-wavelength aerosol lidar observation of persistent hazy weather in Beijing. Laser & Optoelectronics Progress, 56, 240101(2019).
[4] Tian X M, Liu D, Xu J W et al. Review of lidar technology for atmosphere monitoring. Journal of Atmospheric and Environmental Optics, 13, 321-341(2018).
[5] Song Y H, Zhou Y D, Wang L et al. Design of 780 nm high spectral resolution lidar based on laser diode. Chinese Journal of Lasers, 46, 1001006(2019).
[6] Han G, Yan B. Study on testing method for peak power and average power of pulse easer. Industrial Measurement, 18, 4-6(2008).
[7] Wu D Y, Gao S X, Yan D Y et al. The design about high power laser diode linear array coupling with optic fiber. Laser Journal, 23, 19-20(2002).
[8] Zhang G J, Zhang R, Feng K F. Study on the methods of measurement and calibration of the peak power of the narrow pulsed semiconductor laser. Laser Journal, 30, 26-27(2009).
[9] Xiong Y, Lu Y D, Zhu M et al. Design of peak holding circuit for narrow laser pulse. Laser & Infrared, 42, 1377-1380(2012).
[10] Hu Z, Shao L F, Li C et al. Study on the technique for measuring the peak power of narrow pulsed semiconductor laser arrays. Laser & Infrared, 49, 670-674(2019).
[11] Zhou Y J, Ren K, Qian W X et al. Noise analysis of photoelectric detection circuit based on photodiode reverse bias. Infrared and Laser Engineering, 45, 0117003(2016).
[12] Xue R F. Design of a high-speed peak holding circuit with automatic discharge function, 4-9(2017).
[13] Liu H, Zhang Y M, Na Y X. Research on amplification and peak-holding circuits of nanosecond light pulse. Proceedings of SPIE - The International Society for Optical Engineering, 18(2013).
[14] Chow H C, Hor Z. 2008, 672-675(2008).
[15] Haas W, Dullenkopf P. A novel peak amplitude and time detector for narrow pulse signals. IEEE Transactions on Instrumentation and Measurement, 35, 547-550(1986).
[16] Kruiskamp M W, Leenaerts D M W. A CMOS peak detect sample and hold circuit. IEEE Transactions on Nuclear Science, 41, 295-298(1994).
[17] Achtenberg K, Mikołajczyk J, Szabra D et al. Optical pulse monitoring unit for Free Space Optics. Opto-Electronics Review, 27, 291-297(2019).
[18] Du Y, Hua D X, Xin W H et al. Emission energy monitoring of atmospheric detection lidar. Chinese Journal of Quantum Electronics, 35, 209-215(2018).
[19] Lin J R, Chou H P. 2009, 309-312(2009).