[1] Chen Y C. Safety of long-distance pipeline water conveyance project and protection technology of water hammer hazard[J]. Water & Wastewater Engineering, 40, 1-3, 22(2014).
[2] Gao K X, Gao Y, Lou X G. Discussion on safety performance and broken wire detection technology of PCCP[J]. Scientific and Technological Innovation, 104-106(2020).
[3] Zhang S R, Zhang C X, Gu Y[M]. Design, production, construction and numerical analysis of prestressed concrete-filled steel tube (PCCP), 1-10(2009).
[4] Feng X, Li H Z, Chen B Z et al. Numerical investigations into the failure mode of buried prestressed concrete cylinder pipes under differential settlement[J]. Engineering Failure Analysis, 111, 104492(2020).
[5] Wang X, Hu S W, Li W H et al. Use of numerical methods for identifying the number of wire breaks in prestressed concrete cylinder pipe by piezoelectric sensing technology[J]. Construction and Building Materials, 268, 121207(2021).
[6] Dong X N, Dou T S, Dong P et al. Failure experiment and calculation model for prestressed concrete cylinder pipe under three-edge bearing test using distributed fiber optic sensors[J]. Tunnelling and Underground Space Technology, 129, 104682(2022).
[7] Holley M, Diaz R, Giovanniello M. Acoustic monitoring of prestressed concrete cylinder pipe: a case history[C], 1-9(2001).
[8] Zhao X F, Zhang J, Yuan H Y. Considerations of enhancing project safety of PCCP water conveyance[J]. China Water Resources, 42-45(2021).
[10] Xue S G. Analysis and countermeasures of large diameter PCCP pipe bursting in arid and cold areas[J]. China Rural Water and Hydropower, 106-108(2012).
[11] Qi H M, Song J G, Cui Y. Research on electromagnetic NDE inspection method for broken wire of PCCP[J]. Journal of Electrical Engineering, 233-241(2017).
[12] Lin T X, Feng S K, Ye G L et al. Tests for leakage monitoring method of large pressure water pipeline[J]. Journal of Vibration and Shock, 40, 136-142(2021).
[13] Yang L J, Li J Q, Gao S W et al. Leakage monitoring method of natural gas pipeline based on inside-listening[J]. Journal of Shenyang University of Technology, 33, 93-96, 107(2011).
[14] Zhou L K. Study on bearing characteristics and pipeline design of PCCP pipeline[J]. Technical Supervision in Water Resources, 24, 45-47, 82(2016).
[15] Ojdrovic R, Nardini P, Zarghamee M. Verification of PCCP failure margin and risk curves[C], 1413-1423(2011).
[16] Dong X N, Dou T S, Zhao L J et al. An overview on safety assessment of pre-stressed concrete cylinder pipe (PCCP)[J]. Water Resources and Hydropower Engineering, 51, 72-80(2020).
[17] Ma P. Failure mode and cause analysis of prestressed concrete-filled steel tube (PCCP)[J]. Intelligent City, 6, 137-138(2020).
[18] Dou T S, Yan J Q. Failure modes and cause analysis on prestressed concrete cylinder pipe(PCCP)[J]. China Concrete and Cement Products, 29-33(2014).
[19] Yin Y, Yang G Y, Li W W. Production technology of prestressed wire for PCCP[J]. Metal Products, 40, 17-20(2014).
[20] Lu J X. Property analysis of prestressed steel wire for PCCP[J]. Steel Wire Products, 33, 38-40(2007).
[21] Chen J M. Talking about some problems appearing in the manufacturing of 4 m diameter PCCP[J]. Sci-Tech Information Development & Economy, 193-194(2008).
[22] Yang Z G, Jiang Z W, Li W T et al. Influence of different mineral admixtures on corrosion resistance of cement mortar in combined corrosion environment of strong acid and salt in groundwater[J]. Journal of Civil and Environmental Engineering, 37, 82-87(2015).
[23] Zhao M Y, Li J R, Wang L M. Analysis of factors affecting the durability of buried prestressed steel cylinder concrete pipe[J]. Heilongjiang Hydraulic Science and Technology, 38, 32-33(2010).
[24] Zhang X L. Analysis on the corrosion of groundwater to the concrete structure and the precautions[J]. Sci-Tech Information Development & Economy, 272-273(2007).
[25] Peng H B, Dong T G, Huang C J. Research and application of marine concrete admixture[J]. China Concrete, 69-72(2014).
[26] Sun Q R. Cause analysis of water leakage and research on anti-leakage measures for PCCP water transmission pipeline[J]. Science & Technology of Baotou Steel, 34, 79-81(2008).
[27] Bai Y H, Liu Y, Yan Y Z et al. Analysis of reason for PCCP pipe bursting based on fluid structure interaction calculation[J]. China Rural Water and Hydropower, 53-55, 59(2011).
[28] Yao Y. Repair of local drilling damage of large-scale prestressed steel cylinder concrete pipe[J]. Shanxi Water Resources, 25, 52-53(2009).
[30] Xu J, Tian H, Peng Z H et al. Application of remote field eddy current testing in PCCP broken wire inspection[J]. China Concrete and Cement Products, 32-34(2014).
[31] Zhang S K. Attach great importance to product quality in the period of great development of PCCP industry[J]. China Concrete and Cement Products, 1-3(2011).
[32] Wang X H, Zhang H P, Ma H T et al. Comparative experimental study on PCCP broken wire electromagnetic detection equipment[J]. Beijing Water, 59-62(2020).
[33] Schmidt T R. History of the remote-field eddy current inspection technique: materials evaluation, Vol.[J]. Nondestructive Testing, 23, 364-364(1995).
[34] Xu X J, Zhang Z B, Jia Y L. Research on E-shape magnetic core based self-differential mode pick-up coil and its application for fine crack non-destructive testing[C], 76-80(2015).
[35] Si J, Qu M X, Xu F. Finite element analysis on energy flow path of the remote field eddy current effect[J]. Journal of Nanjing University of Aeronautics & Astronautics, 23, 102-108(1991).
[36] Liu Y, Zhang S Q, Yin C et al. Summary of two pipeline electromagnetic nondestructive testing methods[J]. Journal of Mechanical & Electrical Engineering, 31, 844-848, 853(2014).
[37] Jing Y F, Wang X F, Yang B F et al. Simulation research on design of pulsed remote field eddy current sensor for axial crack detection in pipeline[J]. Journal of Air Force Engineering University (Natural Science Edition), 12, 74-78(2011).
[39] Sun Y, Feng H, Sha Z. Application of PCCP monitoring technology based on distributed optical fiber sensing[J]. Water Conservancy Construction and Management, 42, 75-79(2022).
[40] Xiong F, Qu B Y, Zhou G N et al. A broken wire detection system of PCCP pipeline based on Φ-OTDR and MZI[J]. Optoelectronic Technology, 43, 133-141(2023).
[41] Luo J J, Yao X D, Zhang D S et al. In-situ experimental research on spectrum responses of broken wire of large diameter PCCP pipelines(Ⅰ)[J]. China Civil Engineering Journal, 49, 110-116(2016).
[42] Galleher J J, Holley M, Shenkiryk M. Acoustic fiber optic monitoring: how it is changing the remaining service life of the water authority’s pipelines[C], 21-29(2009).
[43] Rajeev P, Kodikara J, Chiu W K et al. Distributed optical fibre sensors and their applications in pipeline monitoring[J]. Key Engineering Materials, 558, 424-434(2013).
[44] Yuan L B, Tong W J, Jiang S et al. Road map of fiber optic sensor technology in China[J]. Acta Optica Sinica, 42, 0100001(2022).
[45] Higgins M S, Paulson P O. Fiber optic sensors for acoustic monitoring of PCCP[C], 1-8(2006).
[46] Bell G, Paulson P. Measurement and analysis of PCCP wire breaks, slips, and delaminations[C], 1016-1024(2010).
[47] Yao X D. Integrated real-time monitoring system of wire-breaking and leakage of PCCP pipeline of ancillary works for South-to-North Water Transfer Project in Beijing[J]. Water Resources and Hydropower Engineering, 47, 67-72(2016).
[48] Qi H M, Song J H, Han J M et al. Monitoring technology of PCCP wire-breaking by distributed FBG sensors[J]. Pipeline Technique and Equipment, 1-4, 8(2018).
[49] Liu D Y, Feng C M, Zhang J et al. Study on broken wire monitoring of ultra-large diameter PCCP pipeline[J]. China Rural Water and Hydropower, 149-153, 159(2020).
[50] Wang W P, Elliott J, Song R X et al. Acoustic fiber optic monitoring system for forewarning of PCCP failure[J]. Water Resources and Hydropower Engineering, 40, 68-70, 77(2009).
[51] Ma B L, Gao R Z, Zhang J J et al. A YOLOX-based automatic monitoring approach of broken wires in prestressed concrete cylinder pipe using fiber-optic distributed acoustic sensors[J]. Sensors, 23, 2090(2023).
[52] Zhang X P, Ding Z W, Hong R et al. Phase sensitive optical time-domain reflective distributed optical fiber sensing technology[J]. Acta Optica Sinica, 41, 0106004(2021).
[53] Wang Z H, Jing H. Analysis of pipeline leakage monitoring index based on distributed optical fiber acoustic sensing system[J]. China Instrumentation, 61-65(2021).
[54] Ji R R, Wan L J, Wu M S. Application of distributed optical fiber acoustic wave sensing technology in PCCP pipeline monitoring[J]. Acoustics and Electronics Engineering, 15-17, 20(2021).
[55] Zhang X P, Chen X H, Liang L et al. Enhanced C-OTDR-based online monitoring scheme for long-distance submarine cables[J]. Acta Optica Sinica, 41, 1306001(2021).
[56] Ali T H, Medjadba H, Simohamed L M et al. Intrusion detection and classification using optical fiber vibration sensor[C](2015).
[57] Li C, Zhang Y M, Liu T G et al. Optic fiber sensors of full-fiberoptic white light interference type[J]. Journal of Transcluction Technology, 14, 91-95(2001).
[58] Wang H Y, Wang Y, Yang J P et al. Dual Mach-Zehnder interferometric optical fiber sensing system based on Burg algorithm[J]. Journal of Electronic Measurement and Instrumentation, 37, 183-191(2023).
[59] Sun Y, Jia B, Zhang T Z. Position determination sensing system based on all-fiber interferometer with feedback loop[J]. Transducer and Microsystem Technologies, 25, 44-46(2006).
[60] Zhang Y X, Xia L, Cao C Q et al. A hybrid single-end-access MZI and Φ-OTDR vibration sensing system with high frequency response[J]. Optics Communications, 382, 176-181(2017).
[61] Shan Y Y, Dong J Y, Zeng J et al. A broadband distributed vibration sensing system assisted by a distributed feedback interferometer[J]. IEEE Photonics Journal, 10, 6800910(2017).
[62] Zhao Z Y, Tang M, Wang L et al. Distributed vibration sensor based on space-division multiplexed reflectometer and interferometer in multicore fiber[J]. Journal of Lightwave Technology, 36, 5764-5772(2018).
[63] Cao Y. Application of PCCP pipeline broken wire monitoring technology in emergency water supply project of Beijing-Shijiazhuang section of the middle route of South-to-North Water Transfer Project (Beijing section)[J]. Beijing Water, 44-48(2017).