• Acta Optica Sinica
  • Vol. 40, Issue 16, 1630002 (2020)
Chang Liu1、2、3, Hailiang Shi1、2、3, Zhiwei Li1、3, Chunqiang Wu4, Chengli Qi4, and Wei Xiong1、2、3、*
Author Affiliations
  • 1Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
  • 2University of Science and Technology of China, Hefei, Anhui 230026, China
  • 3Key Laboratory of Optical Calibration and Characterization of Chinese Academy of Sciences, Hefei, Anhui 230031, China
  • 4Key Laboratory of Radiometric Calibration and Validation for Environmental Satellite, National Satellite Meteorological Center, Beijing 100081, China
  • show less
    DOI: 10.3788/AOS202040.1630002 Cite this Article Set citation alerts
    Chang Liu, Hailiang Shi, Zhiwei Li, Chunqiang Wu, Chengli Qi, Wei Xiong. Detection and Correction of Fringe Count Error in Spaceborne Infrared Hyperspectral Fourier Transform Spectrometer[J]. Acta Optica Sinica, 2020, 40(16): 1630002 Copy Citation Text show less
    References

    [1] Dong C H, Li J, Zhang P et al[M]. Principles and applications of satellite hyperspectral infrared atmospheric remote sensing(2013).

    [2] Zhou F. Inversion and accuracy verification of spectral calibration parameters for spaceborne infrared hyperspectral instrument[D]. Beijing: Chinese Academy of Meteorological Sciences(2019).

    [3] Zhang C M[M]. Interference imaging spectroscopy(2010).

    [4] Oppenheim A V, Willsky A S. Signals and systems[M]. Upper Saddle River: Prentice Hall(1997).

    [5] Zou Y P. Research of on-board data processing techniques for Fourier transform spectrometer Shanghai: Shanghai Institute of Technical Physics,[D]. Chinese Academy of Sciences(2016).

    [6] Li Y, Li S, Gao M G et al. Comparative study on two infrared interferogram acquisition and spectrum recovery methods[J]. Acta Optica Sinica, 35, 0930005(2015).

    [9] Han Y, Revercomb H, Cromp M et al. Suomi NPP CrIS measurements, sensor data record algorithm, calibration and validation activities, and record data quality[J]. Journal of Geophysical Research: Atmospheres, 118, 12734-12748(2013).

    [10] Yang T H, Hu X Q, Xu H L et al. Radiation calibration accuracy assessment of FY-3D hyperspectral infrared atmospheric sounder based on inter-comparison[J]. Acta Optica Sinica, 39, 1130003(2019).

    [11] Feng X, Guo Q, Han C P et al. Correction method of zero path difference position[J]. Journal of Infrared and Millimeter Waves, 36, 795-799(2017).

    Chang Liu, Hailiang Shi, Zhiwei Li, Chunqiang Wu, Chengli Qi, Wei Xiong. Detection and Correction of Fringe Count Error in Spaceborne Infrared Hyperspectral Fourier Transform Spectrometer[J]. Acta Optica Sinica, 2020, 40(16): 1630002
    Download Citation