• Laser & Optoelectronics Progress
  • Vol. 54, Issue 4, 41203 (2017)
An Jingjing*, Gao Nan, Chen Chao, Liu Xiyang, and Zhang Zonghua
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/lop54.041203 Cite this Article Set citation alerts
    An Jingjing, Gao Nan, Chen Chao, Liu Xiyang, Zhang Zonghua. Correcting Method and Evaluation of Eccentricity Error of Circle Target[J]. Laser & Optoelectronics Progress, 2017, 54(4): 41203 Copy Citation Text show less
    References

    [1] Wu Fanlu, Liu Jianjun, Ren Xin, et al. Deep space exploration panoramic camera calibration technique based on circular markers[J]. Acta Optica Sinica, 2013, 33(11): 1115002.

    [2] Zhu Weidong, Cao Lianghong, Mei Biao, et al. Calibration of industrial cameras using asymmetric circle center projection[J]. Optics and Precision Engineering, 2014, 22(8): 2267-2273.

    [3] Tang Zhengzong, Liang Jin, Guo Cheng. Slant-axis digital image correlation method based on photogrammetric correction[J]. Acta Optica Sinica, 2011, 31(11): 1112007.

    [4] Li Zhanli, Liu Mei, Sun Yu. Research on calculation method for the projection of circular target center in photogrammetry[J]. Chinese Journal of Scientific Instrument, 2011, 32(10): 2235-2241.

    [5] Zhang Z H, Huang S J, Meng S S. A simple, flexible and automatic 3D calibration method for a phase calculation-based fringe projection imaging system[J]. Optics Express, 2013, 21(10): 12218-12227.

    [6] Li Zhongwei, Shi Yusheng, Zhong Kai, et al. Projector calibration algorithm for the structured light measurement technique[J]. Acta Optica Sinica, 2009, 29(11): 3061-3065.

    [7] Heikkil A J, Silven O. A four-step camera calibration procedure with implicit image correction[C]. San Juan: IEEE Computer Society Conference on Computer Vision and Pattern Recognition, 1997: 1106-1112.

    [8] Ahn S J, Warnecke H J, Kotowski R. Systematic geometric image measurement errors of circular object targets: mathematical formulation and correction[J]. Photogrammetric Record, 1999, 16(93): 485-502.

    [9] He D, Liu X, Peng X. Eccentricity error identification and compensation for high-accuracy 3D optical measurement[J]. Measurement Science & Technology, 2013, 24(7): 660-664.

    [10] Jiang G, Quan L. Detection of concentric circles for camera calibration[C]. Tenth IEEE International Conference on Computer Vision, 2005, 1(1): 333-340.

    [11] Xing Dekui, Da Feipeng, Zhang Hu. Research and application of locating of circular target with high accuracy[J]. Chinese Journal of Scientific Instrument, 2009, 30(12): 2593-2598.

    [12] Chen Xinyu, Ma Zi, Hu Ying, et al. A new method for accurate location of concentric circles in visual measurement[J]. Journal of Optoelectronics·Laser, 2013, 24(8): 1524-1528.

    [13] Chen Tianfei, Zhao Jibin, Wang Yinling, et al. Calculation for imaging center of circular array targetbased projective transform[J]. Chinese Journal of Scientific Instrument, 2015, 36(4): 895-902.

    [14] Wei Zhenzhong, Zhang Guangjun. Adistortion error model of the perspective projection of ellipse center and its simulation[J]. Chinese Journal of Scientific Instrument, 2003, 24(2): 160-164.

    [15] Zhang Z. A flexible new technique for camera calibration[J]. IEEE Transactions on Pattern Analysis & Machine Intelligence, 2000, 22(11): 1330-1334.

    CLP Journals

    [1] Guo Jirong, Li Changyong, Wurikaixi·Aiyiti. Simple Calibration of Monocular Vision Measurement System in Cladding Layer Detection[J]. Laser & Optoelectronics Progress, 2018, 55(8): 81203

    An Jingjing, Gao Nan, Chen Chao, Liu Xiyang, Zhang Zonghua. Correcting Method and Evaluation of Eccentricity Error of Circle Target[J]. Laser & Optoelectronics Progress, 2017, 54(4): 41203
    Download Citation