• Acta Optica Sinica
  • Vol. 37, Issue 8, 0828006 (2017)
Xiansheng Li1、2, Hongxing Liu2, Jingxu Sun2, Changxi Xue1、*, Jianyue Ren2, Liguo Zhang2, Changzheng Chen2, and Jianwei Ren2
Author Affiliations
  • 1 School of Optoelectronic Engineering, Changchun University of Science and Technology, Changchun, Jilin 130022, China
  • 2 Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin 130033, China
  • show less
    DOI: 10.3788/AOS201737.0828006 Cite this Article Set citation alerts
    Xiansheng Li, Hongxing Liu, Jingxu Sun, Changxi Xue, Jianyue Ren, Liguo Zhang, Changzheng Chen, Jianwei Ren. Relative Radiometric Calibration for Space Camera with Optical Focal Plane Assembly[J]. Acta Optica Sinica, 2017, 37(8): 0828006 Copy Citation Text show less
    References

    [1] Han Qijin, Ma Lingling, Liu Li et al. On-orbit calibration and evaluation of GF-2 satellite based on wide dynamic ground target[J]. Acta Optica Sinica, 35, 0728003(2015).

    [2] Zhang Zhijie, Zhang Hao, Chang Yuguang et al. Review of radiometric calibration methods of Landsat series optical remote sensors[J]. Journal of Remote Sensing, 19, 719-732(2015).

    [3] Xu Na, Wu Ronghua, Hu Xiuqing et al. Integrated method for on-obit wide dynamic vicarious calibration of FY-3C MERSI reflective solar bands[J]. Acta Optica Sinica, 35, 1228001(2015).

    [4] Mendenhall J A, Lencioni D E, Evans J B. Spectral and radiometric calibration of the advanced land imager[J]. Lincoln Laboratory Journal, 5, 207-224(2005). http://www.mendeley.com/research/spectral-radiometric-calibration-advanced-land-imager/

    [5] Lencioni D E, Heam D R, Mendenhall J A et al. EO-1 advanced land imager calibration and performance overview[C]. SPIE, 3750, 89-96(1999).

    [6] Kuester M A, Mccorkel J T, Johnson B R et al. Radiometric calibration concept of imaging spectrometers for a long-term ecological remote sensing project[J]. Photogrammetric Engineering & Remote Sensing, 27, 1487-1500(2008). http://www.asdi.com/getmedia/cdb69534-7abf-4eab-9b01-4cf2c20cb794/RADIOMETRIC-CALIBRATION-CONCEPT-OF-IMAGING-SPECTROMETERS.pdf.aspx

    [7] Montanaro M, Lunsford A, Tesfaye Z et al. Radiometric calibration methodology of the Landsat 8 thermal infrared sensor[J]. Remote Sensing, 6, 8803-8821(2014). http://adsabs.harvard.edu/abs/2014RemS....6.8803M

    [8] Ren Jianwei, Liu Zexun, Wan Zhi et al. Radiometric calibration of off-axis three-mirror-anastigmat space camera with wide viewing field[J]. Optics and Precision Engineering, 18, 1491-1497(2010).

    [9] Ren Huanhuan, Ruan Ping, He Jianwei et al. Study of the radiation calibration of TDI-CCD spatial stereo camera[J]. Acta Optica Sinica, 30, 3476-3480(2010).

    [10] Tao Minghui, Ren Jianyue, Zhang Yu et al. Vignetting correction method of assembled images using reflector[J]. Opto-Electronic Engineering, 38, 45-49(2011).

    [11] Li Xiansheng, Wan Zhi, Liu Zexun et al. The method of CCD test and screening for space camera with wide field of view[J]. Infrared and Laser Engineering, 43, 2245-2250(2014).

    [12] Liu Hongxing, Li Xiansheng, Li Xiaojie et al. Correction of vignetting image for reflector-based mosaic CCD camera[J]. Opto-Electronic Engineering, 42, 9-14(2015).

    [13] Li Xiansheng, Ren Jianyue, Ren Jianwei et al. Establishing method of image model for on-board space camera[J]. Optics and Precision Engineering, 23, 47-53(2015).

    [14] Li Xiansheng, Liu Hongxing, Sun Jingxu et al. Measurement method of the on-orbit MTF without atmosphere effect[J]. Acta Optica Sinica, 36, 0711004(2016).

    [15] Palmer J M, Grant B G[M]. The art of radiometry, 305-307(2010).

    [16] Sun Bin, Li Jinglin, Zhang Xingxiang et al. Interleaving assembly of TDICCDs on 600 mm focal plane[J]. Optics and Precision Engineering, 22, 2908-2913(2014).

    Xiansheng Li, Hongxing Liu, Jingxu Sun, Changxi Xue, Jianyue Ren, Liguo Zhang, Changzheng Chen, Jianwei Ren. Relative Radiometric Calibration for Space Camera with Optical Focal Plane Assembly[J]. Acta Optica Sinica, 2017, 37(8): 0828006
    Download Citation