• Acta Optica Sinica
  • Vol. 41, Issue 7, 0706004 (2021)
Qingming Lü1, Binbin Luo1、*, Qi Yang1, Yang Zhang1, Shengxi Wu2, Zhipeng Gu2, Shenghui Shi1, Decao Wu1, Taojiang Wu3, and Mingfu Zhao1
Author Affiliations
  • 1Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China
  • 2Chongqing Key Laboratory of Medicinal Chemistry and Molecular Pharmacology, Chongqing University of Technology, Chongqing 400054, China
  • 3Chongqing Energy College, Chongqing 402247, China
  • show less
    DOI: 10.3788/AOS202141.0706004 Cite this Article Set citation alerts
    Qingming Lü, Binbin Luo, Qi Yang, Yang Zhang, Shengxi Wu, Zhipeng Gu, Shenghui Shi, Decao Wu, Taojiang Wu, Mingfu Zhao. Immunodetection of Alpha-Fetoprotein Based on Dual-Channel Probe Type 81° Tilted Fiber Grating[J]. Acta Optica Sinica, 2021, 41(7): 0706004 Copy Citation Text show less

    Abstract

    In this study, a dual-channel probe type 81° tilted fiber grating (81°TFG) sensor is proposed and used for the evaluation of alpha-fetoprotein (AFP) immunoassays. First, the end face of 81°TFG is plated with a silver film to form the reflective type 81°TFG, and a dual-channel sensor is constructed by a 2×2 coupler and two 81°TFG probes. Then, large-size AuNs and GO are modified on the grating surface, and AFP monoclonal antibodies are used as the specific recognition unit to modify the grating surface to achieve a dual-channel probe type 81°TFG local surface plasmon resonance (LSPR) AFP immunosensor. Finally, the immune detection experiment is completed in a complex serum environment. The results demonstrated that the detection limit of the sensor for the mass concentration of AFP antigen is within the range of 1--10 pg/mL, the detection saturation point and sensitivity are ~200 ng/mL and ~0.155 nm/log(pg/mL), respectively, it has a satisfactory specific response to the serum of liver cancer patients is observed. Compared with the single-channel transmission type 81°TFG sensor, the sensor could simultaneously control the detection of positive and negative samples of the target molecules; therefore, enhancing the reliability in clinical detection applications, and the operation is simpler and the application potential is greater.
    Qingming Lü, Binbin Luo, Qi Yang, Yang Zhang, Shengxi Wu, Zhipeng Gu, Shenghui Shi, Decao Wu, Taojiang Wu, Mingfu Zhao. Immunodetection of Alpha-Fetoprotein Based on Dual-Channel Probe Type 81° Tilted Fiber Grating[J]. Acta Optica Sinica, 2021, 41(7): 0706004
    Download Citation