• Acta Optica Sinica
  • Vol. 39, Issue 12, 1201001 (2019)
Wentao Wang1、2, Wu Zhou1、2、*, Xiaoshu Cai1、2, Jinwei Qin1、2, Yuhu Huang3, and Aijun Shi3
Author Affiliations
  • 1School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
  • 2Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, Shanghai 200093, China
  • 3Beijing Municipal Research Institute of Environmental Protection, Beijing 100037, China
  • show less
    DOI: 10.3788/AOS201939.1201001 Cite this Article Set citation alerts
    Wentao Wang, Wu Zhou, Xiaoshu Cai, Jinwei Qin, Yuhu Huang, Aijun Shi. Remote Measurement Method for Mass Concentration of Fugitive-Dust-Emission Particulate Based on Backward Light Scattering[J]. Acta Optica Sinica, 2019, 39(12): 1201001 Copy Citation Text show less
    Principle of backward light scattering
    Fig. 1. Principle of backward light scattering
    Image of scattered spot
    Fig. 2. Image of scattered spot
    Flow chart of image processing
    Fig. 3. Flow chart of image processing
    Photograph of portable measuring device for fugitive-dust-emission particulate
    Fig. 4. Photograph of portable measuring device for fugitive-dust-emission particulate
    Typical image of backward light scattering of particulate
    Fig. 5. Typical image of backward light scattering of particulate
    Fitting curve of concentration and relative gray value
    Fig. 6. Fitting curve of concentration and relative gray value
    Corrected gray value as a function of measuring distance
    Fig. 7. Corrected gray value as a function of measuring distance
    Calibration curve of measuring distance
    Fig. 8. Calibration curve of measuring distance
    Relative error of mass concentration of particulates as a function of distance resolution
    Fig. 9. Relative error of mass concentration of particulates as a function of distance resolution
    Particle size as a function of scattered light intensity
    Fig. 10. Particle size as a function of scattered light intensity
    Measurement results of mass concentration and relative error
    Fig. 11. Measurement results of mass concentration and relative error
    Collected images. (a) Image of scattered spot of fugitive-dust-emission particulate; (b) image of background
    Fig. 12. Collected images. (a) Image of scattered spot of fugitive-dust-emission particulate; (b) image of background
    Measurement results of mass concentration for fugitive dust emission
    Fig. 13. Measurement results of mass concentration for fugitive dust emission
    Wentao Wang, Wu Zhou, Xiaoshu Cai, Jinwei Qin, Yuhu Huang, Aijun Shi. Remote Measurement Method for Mass Concentration of Fugitive-Dust-Emission Particulate Based on Backward Light Scattering[J]. Acta Optica Sinica, 2019, 39(12): 1201001
    Download Citation