[1] Huang D, Swanson E A, Lin C P et al. Optical coherence tomography[J]. Science, 254, 1178-1181(1991).
[2] Zhu Y. Research on key technology in full-field optical coherence tomography[D], 39-40(2018).
[3] Fercher A F. Optical coherence tomography[J]. Journal of Biomedical Optics, 1, 157-173(1996).
[4] Vabre L, Dubois A, Boccara A C. Thermal-light full-field optical coherence tomography[J]. Optics Letters, 27, 530-532(2002).
[5] Gao W R. Image contrast reduction mechanism in full-field optical coherence tomography[J]. Journal of Microscopy, 261, 199-216(2016).
[6] Gao W R. Fourier spectrum analysis of full-field optical coherence tomography for tissue imaging[J]. Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, 471, 20150099(2015).
[7] Gao W R. Effects of temporal and spatial coherence on resolution in full-field optical coherence tomography[J]. Journal of Modern Optics, 62, 1764-1774(2015).
[8] Gao W R, Zhu Y. Fractal analysis of en face tomographic images obtained with full field optical coherence tomography[J]. Annalen Der Physik, 529, 1600216(2017).
[9] Zhu Y, Gao W R, Zhou Y et al. Rapid and high-resolution imaging of human liver specimens by full-field optical coherence tomography[J]. Journal of Biomedical Optics, 20, 116010(2015).
[10] Yang Y L. Full-field optical coherence tomography[D], 99-109(2008).
[11] Fercher A F, Mengedoht K, Werner W. Eye-length measurement by interferometry with partially coherent light[J]. Optics Letters, 13, 186-188(1988).
[12] Fercher A F, Hitzenberger C, Juchem M. Measurement of intraocular optical distances using partially coherent laser light[J]. Journal of Modern Optics, 38, 1327-1333(1991).
[13] Hitzenberger C K. Mêasurement of corneal thickness by low-coherence interferometry[J]. Applied Optics, 31, 6637-6642(1992).
[14] Hitzenberger C K, Drexler W, Fercher A F. Measurement of corneal thickness by laser Doppler interferometry[J]. Investigative Ophthalmology & Visual Science, 33, 98-103(1992).
[15] Yang Y L, Ding Z H, Meng J et al. Common path optical coherence tomographic system suitable for endoscopic imaging[J]. Acta Optica Sinica, 28, 955-959(2008).
[16] Zhu X M, Gao W R, Zhu Y. Improved Köhler illumination-based full-field optical coherence tomography system[J]. Acta Optica Sinica, 34, 0511002(2014).
[17] Tang Y F, Gao W R. Effects of orientation deviation of a beam splitter and a reference mirror on the stability of a two-interferometer-based handheld FFOCT imaging probe[J]. Applied Optics, 60, 5942-5952(2021).
[18] Bamford K, James J, Barr H et al. Optical radar detection of precancerous bronchial tissue[J]. Lasers in Medical Science, 15, 188-194(2000).