• Laser & Optoelectronics Progress
  • Vol. 60, Issue 23, 2312004 (2023)
Jiawei Zhou1、2, Wang Cheng2, Chenxuan Yin2、3, Guangyan Guo2、3, Lifen Liao2、3, Hong Zhang1, Yi Li1, Qiangqiang Zhu1, Le Wang1、**, and Yunfeng Ma2、3、*
Author Affiliations
  • 1College of Optical and Electronic Technology, China Jiliang University, Hangzhou 310018, Zhejiang, China
  • 2Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
  • 3School of Optoelectronics, University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.3788/LOP222868 Cite this Article Set citation alerts
    Jiawei Zhou, Wang Cheng, Chenxuan Yin, Guangyan Guo, Lifen Liao, Hong Zhang, Yi Li, Qiangqiang Zhu, Le Wang, Yunfeng Ma. An Allocation Method of Laser Damage Test Point Based on Nonlinear Fitting[J]. Laser & Optoelectronics Progress, 2023, 60(23): 2312004 Copy Citation Text show less

    Abstract

    As an indispensable indicator in the development of optical components, laser-induced damage threshold (LIDT) is still the direction of research to improve the accuracy of its measurement results. In this paper, an optimal allocation method of damage test points based on Monte Carlo method is proposed to improve the accuracy of LIDT fitting results. According to the limited irradiation test area and irradiation spot size of the test sample, a nonlinear degenerate defect damage model is simulated, and the sensitivity analysis of the influence of test points change on the fitting LIDT results at different fluence levels is analyzed. Then, according to the setting parameters of damage model, a model is established to generate relevant damage data. The number of test points at each specified fluence level is changed by the control variable method, with the number of test points unchanged at the rest of the fluences.The Monte Carlo method is used to perform multiple simulation calculations on all damage data. The relationship curve between the standard deviation of the fitting results and the test points is drawn, so as to calculate the sensitivity of the corresponding test points to the standard deviation of the damage threshold fitting result. Finally, a more reasonable allocation of test points under each fluence is carried out with this sensitivity as the weight. The results show that the standard deviation of the fitting result of the sensitivity weight method is 0.272 J/cm2, which is about 31% lower than the standard deviation of 0.395 J/cm2 in the standard distribution method.
    Jiawei Zhou, Wang Cheng, Chenxuan Yin, Guangyan Guo, Lifen Liao, Hong Zhang, Yi Li, Qiangqiang Zhu, Le Wang, Yunfeng Ma. An Allocation Method of Laser Damage Test Point Based on Nonlinear Fitting[J]. Laser & Optoelectronics Progress, 2023, 60(23): 2312004
    Download Citation