For a general asymmetrio optical system, the Fourier transform conditions of the system are derived by using the ray matrix method. Taking account of the positioning error, the formulas for determining fraunhofer diffraction, Fourier transform and its physical focal depth region are obtained. The displacement of the spectral plane is also obtained as the incident light is of different wavefront. Two asymmetric systems as the examples are analyzed.