• Chinese Journal of Lasers
  • Vol. 45, Issue 2, 207002 (2018)
Shuang Wang1 and Haishan Zeng2、3、*
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: 10.3788/CJL201845.0207002 Cite this Article Set citation alerts
    Shuang Wang, Haishan Zeng. Real-Time in vivo Raman Spectroscopy and Its Clinical Applications in Early Cancer Detection[J]. Chinese Journal of Lasers, 2018, 45(2): 207002 Copy Citation Text show less
    References

    [1] Vodinh T. Biomedical photonics handbook[J]. Journal of Biomedical Optics, 9, 1110-1111(2003).

    [2] Zhang Z X[M]. New technologies and applications of biomedical photonics(2008).

    [3] Mcgregor H C, Wang W, Short M et al. Clinical utility of Raman spectroscopy: Current applications and ongoing developments[J]. Advanced Health Care Technologies, 2, 13-29(2016). http://www.researchgate.net/publication/304341022_Clinical_utility_of_Raman_spectroscopy_current_applications_and_ongoing_developments

    [4] Ellis D I, Cowcher D P, Ashton L et al. Illuminating disease and enlightening biomedicine: Raman spectroscopy as a diagnostic tool[J]. Analyst, 138, 3871-3884(2013). http://www.ncbi.nlm.nih.gov/pubmed/23722248

    [5] Wang W, Zhao J, Short M et al. Real-time in vivo cancer diagnosis using Raman spectroscopy[J]. Journal of Biophotonics, 8, 527-545(2015). http://onlinelibrary.wiley.com/doi/10.1002/jbio.201400026/pdf

    [6] Popp J, Popp J. 临床生物医学光子学[J]. 光学与光电技术, 14, 9-12(2016). http://www.opticsjournal.net/Articles/Abstract?aid=OJ1612230001487C9FbI

         Clinical biophotonics[J]. Optics & Optoelectronic Technology, 14, 9-12(2016).

    [7] Xu Z H, Huang W, Lin D et al. Advances in Raman spectroscopy for nasopharyngeal carcinoma tissue[J]. Spectroscopy and Spectral Analysis, 36, 2518-2521(2016).

    [8] Zeng H, Mcwilliams A, Lam S. Optical spectroscopy and imaging for early lung cancer detection: A review[J]. Photodiagnosis and Photodynamic Therapy, 1, 111-122(2004). http://www.sciencedirect.com/science/article/pii/S1572100004000420

    [9] Eldiasty F. Coherent anti-Stokes Raman scattering: Spectroscopy and microscopy[J]. Vibrational Spectroscopy, 55, 1-37(2011). http://www.sciencedirect.com/science/article/pii/S0924203110001499

    [10] Holtom G R, Zumbusch A, Xie X S. Coherent anti-Stokes Raman scattering microscopy[C]. Conference on Lasers and Electro-Optics(1999).

    [11] Rodriguez L, Lockett S, Holtom G R. Coherent anti-Stokes Raman scattering microscopy: A biological review[J]. Cytometry Part A, 69, 779-791(2006). http://onlinelibrary.wiley.com/doi/10.1002/cyto.a.20299/full

    [12] Cheng J. Coherent anti-Stokes Raman scattering microscopy[J]. Applied Spectroscopy, 61, 197-208(2007).

    [13] Lord R C. Introduction to infrared and Raman spectroscopy[J]. Journal of the American Chemical Society, 87, 1155-1156(1965).

    [14] Ball D W. Theory of Raman spectroscopy[J]. Spectroscopy, 16, 32-34(2001).

    [15] Hanlon E B, Manoharan R, Koo T et al. Prospects for in vivo Raman spectroscopy[J]. Physics in Medicine and Biology, 45, R1(2000).

    [16] Zhao W L, Zhang Y, Li R et al. Study of Raman spectrum in diagnosis of malignant cancer[J]. Laser Journal, 29, 72-73(2008).

    [17] Motz J T, Gandhi S J, Scepanovic O R et al. Real-time Raman system for in vivo disease diagnosis[J]. Journal of Biomedical Optics, 10, 031113(2005). http://europepmc.org/abstract/MED/16229638

    [18] Zeng H. Real-time in vivo Raman spectroscopy-technology development and clinical applications in early cancer detection[C]. Bio-Optics: Design and Application, OSA, Hawaii, BM2A, 1(2013).

    [19] Jermyn M, Desroches J, Aubertin K et al. A review of Raman spectroscopy advances with an emphasis on clinical translation challenges in oncology[J]. Physics in Medicine and Biology, 61, R370-R400(2016). http://europepmc.org/abstract/med/27804917

    [20] Culha M. Raman spectroscopy for cancer diagnosis: How far have we come?[J]. Bioanalysis, 7, 2813-2824(2015). http://www.ncbi.nlm.nih.gov/pubmed/26563592

    [21] Mccreery R L. Raman spectroscopy for chemical analysis[J]. Measurement Science and Technology, 12, 653-654(2001). http://onlinelibrary.wiley.com/book/10.1002/0471721646

    [22] Matousek P, Morris M D. Emerging Raman applications and techniques in biomedical and pharmaceutical fields[M]. New York: Springer(2010).

    [23] Boustany N N, Crawford J M, Manoharan R et al. Effects of freeze-thaw and photobleaching on the ultraviolet resonance Raman spectra of human colon biopsies[J]. Applied Spectroscopy, 55, 1506-1513(2001). http://www.opticsinfobase.org/as/abstract.cfm?uri=as-55-11-1506

    [24] Patit C A, Pence I J, Lieber C A et al. 1064 nm dispersive Raman spectroscopy of tissues with strong near-infrared autofluorescence[J]. Optics Letters, 39, 303-306(2014). http://www.opticsinfobase.org/abstract.cfm?uri=ol-39-2-303

    [25] Wang W, Major A, Paliwal J. Grating-stabilized external cavity diode lasers for Raman spectroscopy—A review[J]. Applied Spectroscopy Reviews, 47, 116-143(2012). http://www.tandfonline.com/doi/full/10.1080/05704928.2011.631649

    [26] Huang Z. McWilliams A, Lui H, et al. Near-infrared Raman spectroscopy for optical diagnosis of lung cancer[J]. International Journal of Cancer, 107, 1047-1052(2003).

    [27] Teh S K, Zheng W, Ho K Y et al. Diagnostic potential of near-infrared Raman spectroscopy in the stomach: Differentiating dysplasia from normal tissue[J]. British Journal of Cancer, 98, 457-465(2008). http://pubmedcentralcanada.ca/pmcc/articles/PMC2361456/

    [28] Lyng F M, Faolain E O, Conroy J et al. Vibrational spectroscopy for cervical cancer pathology, from biochemical analysis to diagnostic tool[J]. Experimental and Molecular Pathology, 82, 121-129(2007). http://europepmc.org/abstract/MED/17320864

    [29] Zeng H. Basics of endoscopy and light-tissue interactions[M]. //Diagnostic endoscopy. Abingdon: Taylor & Francis, 1-2(2013).

    [30] Schwab S D, Mccreery R L, Gamble F T. Normal and resonance Raman spectroelectrochemistry with fiber optic light collection[J]. Analytical Chemistry, 58, 2486-2492(1986). http://pubs.acs.org/doi/abs/10.1021/ac00125a029

    [31] Myrick M L, Angel S M. Elimination of background in fiber-optic Raman measurements[J]. Applied Spectroscopy, 44, 565-570(1990). http://www.opticsinfobase.org/abstract.cfm?uri=as-44-4-565

    [32] Chong C K, Shen C, Fong Y et al. Raman spectroscopy with a fiber-optic probe[J]. Vibrational Spectroscopy, 3, 35-45(1992).

    [33] Bhowmick G K, Gautam N, Gantayet L M. Design optimization of fiber optic probes for remote fluorescence spectroscopy[J]. Optics Communications, 282, 2676-2684(2009). http://www.sciencedirect.com/science/article/pii/S0030401809003770

    [34] Frank C J. Redd D C B, Gansler T S, et al. Characterization of human breast biopsy specimens with near-IR Raman spectroscopy[J]. Analytical Chemistry, 66, 319-326(1994).

    [35] Baraga J J, Feld M S, Rava R P. Rapid near-infrared Raman spectroscopy of human tissue with a spectrograph and CCD detector[J]. Applied Spectroscopy, 46, 187-190(1992). http://www.opticsinfobase.org/abstract.cfm?uri=as-46-2-187

    [36] Gupta N, Dahmani R. AOTF Raman spectrometer for remote detection of explosives[J]. Spectrochimica Acta Part A, 56, 1453-1456(2000). http://www.sciencedirect.com/science/article/pii/S1386142599002656

    [37] Cullum B M, Mobley J, Stokes D L et al. Development of a portable Raman spectrometer for medical diagnostics[C]. SPIE, 4615, 82-90(2002).

    [38] Tanaka K. Pacheco M T T, Brennan J F, et al. Compound parabolic concentrator probe for efficient light collection in spectroscopy of biological tissue[J]. Applied Optics, 35, 758-763(1996).

    [39] Huang Z, Zeng H, Hamzavi I et al. Rapid near-infrared Raman spectroscopy system for real-time in vivo skin measurements[J]. Optics Letters, 26, 1782-1784(2001). http://europepmc.org/abstract/MED/18059697

    [40] Zeng H, Lui H, Huang Z. Apparatus. -11-26[P]. methods related high speed Raman spectroscopy: US6485948.(2002).

    [41] Esmondewhite F W L, Esmondewhite K A, Morris M D. Minor distortions with major consequences: Correcting distortions in imaging spectrographs[J]. Applied Spectroscopy, 65, 85-98(2011). http://www.ncbi.nlm.nih.gov/pubmed/21211158

    [42] Lui H, Zhao J. McLean D I, et al. Real-time Raman spectroscopy for in vivo skin cancer diagnosis[J]. Cancer Research, 72, 2491-2500(2012).

    [43] Zhao J, Lui H. McLean D I, et al. Integrated real-time Raman system for clinical in vivo skin analysis[J]. Skin Research and Technology, 14, 484-492(2008).

    [44] Yi W S, Jiang H M. Application and research progress of Raman spectroscopy diagnosis in the gastric cancer[J]. Acta Laser Biology Sinica, 20, 280-284(2011).

    [45] Cao A, Pandyaa A K, Serhatkulu G K et al. A robust method for automated background subtraction of tissue fluorescence[J]. Journal of Raman Spectroscopy, 38, 1199-1205(2007). http://onlinelibrary.wiley.com/doi/10.1002/jrs.1753/full

    [46] Clupek M, Matejka P, Volka K. Noise reduction in Raman spectra: Finite impulse response filtration versus Savitzky-Golay smoothing[J]. Journal of Raman Spectroscopy, 38, 1174-1179(2007). http://onlinelibrary.wiley.com/doi/10.1002/jrs.1747/full

    [47] Aarchibald D D, Kays S E, Himmesbach D S et al. Raman and NIR spectroscopic methods for determination of total dietary fiber in cereal foods: A comparative study[J]. Applied Spectroscopy, 52, 22-31(1998). http://www.opticsinfobase.org/abstract.cfm?uri=as-52-1-22

    [48] Zhao J, Lui H. McLean D I, et al. Automated autofluorescence background subtraction algorithm for biomedical Raman spectroscopy[J]. Applied Spectroscopy, 61, 1225-1232(2007). http://www.opticsinfobase.org/VJBO/abstract.cfm?uri=as-61-11-1225

    [49] Rowlands C J, Elliott S R. Automated algorithm for baseline subtraction in spectra[J]. Journal of Raman Spectroscopy, 42, 363-369(2011). http://onlinelibrary.wiley.com/doi/10.1002/jrs.2691/full

    [50] Rieppo L, Saarakkala S, Narhi T et al. Application of second derivative spectroscopy for increasing molecular specificity of Fourier transform infrared spectroscopic imaging of articular cartilage[J]. Osteoarthritis and Cartilage, 20, 451-459(2012). http://www.ncbi.nlm.nih.gov/PubMed/22321720?dopt=Abstract

    [51] Short M, Lam S. McWilliams A, et al. Using laser Raman spectroscopy to reduce false positives of autofluorescence bronchoscopies: A pilot study[J]. Journal of Thoracic Oncology, 6, 1206-1214(2011). http://www.sciencedirect.com/science/article/pii/S1556086415310364

    [52] Cluff G M, Short M A, Lui H et al. Comparison of connective tissue invaded by Lewis lung carcinoma to healthy connective tissue by means of micro-Raman spectroscopy[J]. Journal of Raman Spectroscopy, 40, 1087-1090(2009). http://onlinelibrary.wiley.com/doi/10.1002/jrs.2257/pdf

    [53] Feng S, Chen R, Lin J et al. Gastric cancer detection based on blood plasma surface-enhanced Raman spectroscopy excited by polarized laser light[J]. Biosensors and Bioelectronics, 26, 3167-3174(2011). http://www.sciencedirect.com/science/article/pii/S0956566310008390

    [54] Huang Z, Lui H. McLean D I, et al. Raman spectroscopy in combination with background near-infrared autofluorescence enhances the in vivo assessment of malignant tissues[J]. Photochemistry and Photobiology, 81, 1219-1226(2005). http://www.bioone.org/doi/abs/10.1562/2005-02-24-RA-449

    [55] Bonnier F, Byrne H J. Understanding the molecular information contained in principal component analysis of vibrational spectra of biological systems[J]. Analyst, 137, 322-332(2012). http://europepmc.org/abstract/MED/22114757

    [56] Li Y Z, Feng S Y, Lin J Q et al. Statistical analysis of tissue Raman spectroscopy[J]. Acta Laser Biology Sinica, 20, 130-133(2011).

    [57] Brun N, Poncot M, Bourson P. Raman correlation spectroscopy: A method studying physical properties of polystyrene by the means of multivariate analysis[J]. Chemometrics and Intelligent Laboratory Systems, 128, 77-82(2013). http://www.sciencedirect.com/science/article/pii/S0169743913001457

    [58] Jiang C Z. Research on data processing and qualitative analysis of Raman spectrum Changchun: Changchun Institute of Optics, Fine Mechanics and Physics,[D]. Chinese Academy of Sciences, 78-80(2014).

    [59] Godar D E. Worldwide increasing incidences of cutaneous malignant melanoma[J]. Journal of Skin Cancer, 2011, 858425(2011). http://www.ncbi.nlm.nih.gov/pubmed/22007306

    [60] Chen W, Zheng R, Baade P D et al. Cancer statistics in China, 2015[J]. CA: A Cancer Journal for Clinicians, 66, 115-132(2016). http://onlinelibrary.wiley.com/doi/10.3322/caac.21338/pdf

    [61] Vollmer R T. The dynamics of death in melanoma[J]. Journal of Cutaneous Pathology, 39, 1075-1082(2012). http://europepmc.org/abstract/MED/23072441

    [62] Fox G N. ABCD-EFG for diagnosis of melanoma[J]. Clinical and Experimental Dermatology, 30, 707(2005). http://onlinelibrary.wiley.com/doi/10.1111/j.1365-2230.2005.01857.x/full

    [63] Zhao J, Lui H, Kalia S et al. Real-time Raman spectroscopy for automatic in vivo skin cancer detection: An independent validation[J]. Analytical and Bioanalytical Chemistry, 407, 8373-8379(2015). http://europepmc.org/abstract/MED/26231688

    [64] Wang S, Zhao J, Lui H et al. Monte Carlo simulation of in vivo Raman spectral measurements of human skin with a multi-layered tissue optical model[J]. Journal of Biophotonics, 7, 703-712(2014). http://europepmc.org/abstract/med/24307289

    [65] Wang S. Study on cutaneous melanin near-infrared autofluorescence and Raman spectrum properties Xi'an:[D]. Northwest University, 37-39(2011).

    [66] Zhao J, Mclean D I, Zeng H. Real-time Raman spectroscopy for noninvasive in vivo skin analysis and diagnosis[M]. //Campolo D. New developments in biomedical engineering. Rijeka, Croatia: INTECH Open Access Publisher(2010).

    [67] Zhao J, Zeng H, Kalia S et al. Wavenumber selection based analysis in Raman spectroscopy improves skin cancer diagnostic specificity[J]. Analyst, 141, 1034-1043(2016). http://www.ncbi.nlm.nih.gov/pubmed/26767205

    [68] Ong Y H, Lim M, Liu Q. Comparison of principal component analysis and biochemical component analysis in Raman spectroscopy for the discrimination of apoptosis and necrosis in K562 leukemia cells[J]. Optics Express, 20, 22158-22171(2012). http://www.opticsinfobase.org/abstract.cfm?uri=oe-20-20-22158

    [69] Xu X, Yang J F, Wu F C et al. Spectra classification based on generalized discriminant analysis[J]. Spectroscopy and Spectral Analysis, 26, 1960-1964(2006).

    [70] Berger A J, Koo T, Itzkan I et al. Multicomponent blood analysis by near-infrared Raman spectroscopy[J]. Applied Optics, 38, 2916-2926(1999). http://www.ncbi.nlm.nih.gov/pubmed/18319874

    [71] Barker M L, Rayens W S. Partial least squares for discrimination[J]. Journal of Chemometrics, 17, 166-173(2003).

    [72] Provost F, Fawcett T. Robust classification for imprecise environments[J]. Machine Learning, 42, 203-231(2001). http://bib.oxfordjournals.org/external-ref?access_num=10.1023/A:1007601015854&link_type=DOI

    [73] Mcgergor H C, Short M, Mcwilliams A et al. Real-time endoscopic Raman spectroscopy for in vivo early lung cancer detection[J]. Journal of Biophotonics, 10, 98-110(2017). http://onlinelibrary.wiley.com/doi/10.1002/jbio.201500204/full

    [74] Adams N M, Hand D J. Comparing classifiers when the misallocation costs are uncertain[J]. Pattern Recognition, 32, 1139-1147(1999). http://www.sciencedirect.com/science/article/pii/S003132039800154X

    [75] Chen W, Zheng R, Zeng H et al. Epidemiology of lung cancer in China[J]. Thoracic Cancer, 6, 209-215(2015). http://www.ncbi.nlm.nih.gov/pubmed/26273360/

    [76] Yan L, Xu L. Global efforts in conquering lung cancer in China[J]. Chinese Journal of Cancer, 34, 320-322(2015). http://kns.cnki.net/KCMS/detail/detail.aspx?filename=aizh201507006&dbname=CJFD&dbcode=CJFQ

    [77] Yang F H, Zhang C D. Research status of lung cancer[J]. China Continuing Medical Education, 7, 30-31(2015).

    [78] Hirsch F R, Franklin W A, Gazdar A F et al. Early detection of lung cancer: Clinical perspectives of recent advances in biology and radiology[J]. Clinical Cancer Research, 7, 5-22(2001). http://europepmc.org/abstract/MED/11205917

    [79] Zeng H, Petek M, Zorman M T et al. Integrated endoscopy system for simultaneous imaging and spectroscopy for early lung cancer detection[J]. Optics Letters, 29, 587-589(2004). http://europepmc.org/abstract/MED/15035479

    [80] Fawzy Y, Petek M, Tercelj M et al. In vivo assessment and evaluation of lung tissue morphologic and physiological changes from non-contact endoscopic reflectance spectroscopy for improving lung cancer detection[J]. Journal of Biomedical Optics, 11, 044003(2006). http://scitation.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=JBOPFO000011000004044003000001&idtype=cvips&gifs=Yes

    [81] Short M, Lam S. McWilliams A, et al. Development and preliminary results of an endoscopic Raman probe for potential in vivo diagnosis of lung cancers[J]. Optics Letters, 33, 711-713(2008). http://scitation.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=VIRT02000015000010000137000001&idtype=cvips&gifs=Yes

    [82] Pawluk H C, Short M, Lam S et al. Improvements to a laser Raman spectroscopy system for reducing the false positives of autofluorescence bronchoscopies[C]. SPIE, 8207, 820737(2012).

    [83] Lam S, Kennedy T C, Unger M et al. Localization of bronchial intraepithelial neoplastic lesions by fluorescence bronchoscopy[J]. Chest, 113, 696-702(1998). http://thorax.bmj.com/external-ref?access_num=10.1378/chest.113.3.696&link_type=DOI

    [84] Movasaghi Z, Rehman S, Rehman I. Raman spectroscopy of biological tissues[J]. Applied Spectroscopy Reviews, 42, 493-541(2007). http://www.tandfonline.com/doi/full/10.1080/05704920701551530

    [85] Hill I R, Levin I W. Vibrational spectra and carbon-hydrogen stretching mode assignments for a series of n-alkyl carboxylic acids[J]. Journal of Chemical Physics, 70, 842-851(1979). http://scitation.aip.org/content/aip/journal/jcp/70/2/10.1063/1.437517%3Bjsessionid=1qghrjkliun81.x-aip-live-02

    [86] Krafft C, Neudert L, Simat T J et al. Near infrared Raman spectra of human brain lipids[J]. Spectrochimica Acta Part A, 61, 1529-1535(2005). http://europepmc.org/abstract/MED/15820887

    [87] Baeten V, Hourant P, Morales M T et al. Oil and fat classification by FT-Raman spectroscopy[J]. Journal of Agricultural and Food Chemistry, 46, 2638-2646(1998). http://pubs.acs.org/doi/abs/10.1021/jf9707851

    [88] Streiner D L. Regression in the service of the superego: The do's and don'ts of stepwise multiple regression[J]. The Canadian Journal of Psychiatry, 39, 191-196(1994). http://europepmc.org/abstract/MED/8044725

    [89] Leardi R, Gonzalez A L. Genetic algorithms applied to feature selection in PLS regression: How and when to use them[J]. Chemometrics and Intelligent Laboratory Systems, 41, 195-207(1998). http://www.sciencedirect.com/science/article/pii/S0169743998000513

    [90] Sun J, Garfield D H, Lam B et al. The value of autofluorescence bronchoscopy combined with white light bronchoscopy compared with white light alone in the diagnosis of intraepithelial neoplasia and invasive lung cancer: A meta-analysis[J]. Journal of Thoracic Oncology, 6, 1336-1344(2011).

    Shuang Wang, Haishan Zeng. Real-Time in vivo Raman Spectroscopy and Its Clinical Applications in Early Cancer Detection[J]. Chinese Journal of Lasers, 2018, 45(2): 207002
    Download Citation