• Spectroscopy and Spectral Analysis
  • Vol. 42, Issue 11, 3476 (2022)
Kang-ting YAN1、*, Yi-fang HAN1、1; 2;, Lin-lin WANG1、1; 2;, Fan DING3、3;, Yu-bin LAN1、1; 2; *;, and Ya-li ZHANG2、2; 3; *;
Author Affiliations
  • 11. College of Electronic Engineering, College of Artificial Intelligence, South China Agricultural University, Guangzhou 510642, China
  • 22. National Center for International Collaboration Research on Precision Agricultural Aviation Pesticides Spraying Technology, Guangzhou 510642, China
  • 33. College of Engineering, South China Agricultural University, Guangzhou 510642, China
  • show less
    DOI: 10.3964/j.issn.1000-0593(2022)11-3476-06 Cite this Article
    Kang-ting YAN, Yi-fang HAN, Lin-lin WANG, Fan DING, Yu-bin LAN, Ya-li ZHANG. Research on the Fluorescence Spectra Characteristics of Abamectin Technical and Preparation Solution[J]. Spectroscopy and Spectral Analysis, 2022, 42(11): 3476 Copy Citation Text show less
    Three-dimensional fluorescence spectrum of 20 mg·L-1 abamectin technical solution1: Ex/Em=270 /297 nm; Int.=111.772
    Fig. 1. Three-dimensional fluorescence spectrum of 20 mg·L-1 abamectin technical solution
    1: Ex/Em=270 /297 nm; Int.=111.772
    Fitting curve of abamectin technical solution
    Fig. 2. Fitting curve of abamectin technical solution
    The linear fit between the predicted value and the measured value in thevalidation set of abamectin technical
    Fig. 3. The linear fit between the predicted value and the measured value in thevalidation set of abamectin technical
    1∶1 000 abamectin pharmaceutical solution three-dimensional fluorescence spectrum(a): Formulation 1; 1: Ex/Em=270/291.5 nm, Int.=2 901.22; (b): Formulation 2; 1: Ex/Em=270/291 nm, Int.=2 774.06
    Fig. 4. 1∶1 000 abamectin pharmaceutical solution three-dimensional fluorescence spectrum
    (a): Formulation 1; 1: Ex/Em=270/291.5 nm, Int.=2 901.22; (b): Formulation 2; 1: Ex/Em=270/291 nm, Int.=2 774.06
    Fitting curve of abamectin preparation solution(a): Formulation 1; (b): Formulation 2
    Fig. 5. Fitting curve of abamectin preparation solution
    (a): Formulation 1; (b): Formulation 2
    The linear fit curve between the predicted value and the measured value in the validation set of abamectin preparations(a): Formulation 1; (b): Formulation 2
    Fig. 6. The linear fit curve between the predicted value and the measured value in the validation set of abamectin preparations
    (a): Formulation 1; (b): Formulation 2
    溶液阿维菌素有效成分浓度梯度配制/(mg·L-1)
    阿维菌素原药溶液10.0, 12.0, 13.0, 15.0, 16.0, 18.0, 20.0, 22.0, 23.0, 25.0, 26.0, 28.0, 30.0, 32.0, 33.0, 35.0(校正集)
    11.0, 14.0, 17.0, 21.0, 24.0, 27.0, 31.0, 34.0(验证集)
    阿维菌素制剂溶液10.02, 11.07, 11.69, 12.32, 12.74, 13.99, 14.41, 15.45, 16.7, 18.17, 20.88, 23.18, 24.64, 27.77, 32.16(校正集)
    10.44, 11.90, 13.15, 14.82, 17.33, 21.92, 26.10, 29.86(验证集)
    Table 1. Concentration gradient of abamectin technical and preparation solution preparation
    序号浓度/(mg·L-1)荧光强度/(Int.)Em/nm
    11081.534 6298.0
    21594.261 7297.5
    320112.423 0297.5
    425127.412 0297.5
    530140.347 0297.5
    635157.746 0297.5
    Table 2. Two-dimensional fluorescence spectroscopy data of abamectin technical solution
    序号浓度/
    (mg·L-1)
    荧光强度/(Int.)Em/nm
    制剂1制剂2制剂1制剂2
    110.029 475.665 428.42288.5289.0
    215.455 407.924 988.47290.0290.0
    320.882 994.122 944.72291.5291.5
    424.642 687.862 846.94292.0291.0
    532.161 524.541 426.21293.5293.5
    Table 3. Relevant data of two-dimensional fluorescence spectroscopy of abamectin technical solution
    Kang-ting YAN, Yi-fang HAN, Lin-lin WANG, Fan DING, Yu-bin LAN, Ya-li ZHANG. Research on the Fluorescence Spectra Characteristics of Abamectin Technical and Preparation Solution[J]. Spectroscopy and Spectral Analysis, 2022, 42(11): 3476
    Download Citation