• Acta Optica Sinica
  • Vol. 38, Issue 6, 0612007 (2018)
Song Ye1、2, Yongfeng Sun1、2、3, Zhiwei Li1、2, Hailiang Shi1、2、*, Wei Xiong1、2, Xinqiang Wang1、2, Jiejun Wang1、2, and Wentao Zhang1、2
Author Affiliations
  • 1 Anhui Institute of Optics and Fine Mechanics Chinese Academy of Sciences, Hefei, Anhui 230031, China
  • 1 School of Electronic Engineering and Automation Guilin University of Electronic Technology, Guilin, Guangxi 541004, China
  • 2 Anhui Institute of Optics and Fine Mechanics Chinese Academy of Sciences, Hefei, Anhui 230031, China
  • 2 Guang xi Key Laboratory of Optoelectronic Information Processing Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China
  • 2 Key Laboratory of General Optical Calibration and Characterization Chinese Academyof Sciences, Hefei ,Anhui 230031, China
  • 3 Key Laboratory of General Optical Calibration and Characterization Chinese Academyof Sciences, Hefei ,Anhui 230031, China
  • show less
    DOI: 10.3788/aos201838.0612007 Cite this Article Set citation alerts
    Song Ye, Yongfeng Sun, Zhiwei Li, Hailiang Shi, Wei Xiong, Xinqiang Wang, Jiejun Wang, Wentao Zhang. [J]. Acta Optica Sinica, 2018, 38(6): 0612007 Copy Citation Text show less
    References

    [1] Dong C H, Li J, Zhang P et al[M]. Principle and application of satellite hyperspectral infrared atmospheric remote sensing(2013).

    [2] Xiong W, Shi H L, Wang Y J et al. Study on near-infrared spatial heterodyne spectrometer and detection of water vapor[J]. Acta Optica Sinica, 30, 1511-1515(2010).

    [3] Rogalski A, Antoszewski J, Faraone L. Third-generation infrared photodetector arrays[J]. Journal of Applied Physics, 105, 091101(2009). http://scitation.aip.org/content/aip/journal/jap/105/9/10.1063/1.3099572

    [4] Li Z W, Xiong W, Shi H L et al. Correction of detector response error for hyperspectral spatial heterodyne interferometer[J]. Acta Optica Sinica, 34, 0530001(2014).

    [5] Tang X, Yi W N, Du L L et al. Adjacency effect correction study of GF-1 satellite multi-spectral remote sensing images[J]. Acta Optica Sinica, 36, 0228003(2016).

    [7] Carter R O, Lindsay N E, Beduhn D. A solution to baseline uncertainty due to MCT detector nonlinearity in FY-IR[J]. Applied Spectroscopy, 44, 1147-1151(1990). http://www.opticsinfobase.org/abstract.cfm?uri=as-44-7-1147

    [8] Han Y, Revercomb H, Cromp M et al. Suomi NPP CrIS measurements, sensor data record algorithm, calibration and validation activities, and record data quality[J]. Journal of Geophysical Research Atmospheres, 118, 12734-12748(2013). http://onlinelibrary.wiley.com/doi/10.1002/2013JD020344/abstract

    [9] Gong H M, Shao X M, Li X Y et al. Advanced technology and application of spaceborne infrared detectors[J]. Infrared and Laser Engineering, 41, 3129-3140(2012).

    [10] Broudy R M, Reine M B. Advances in HgCdTe infrared focal plane technology[C]. SPIE, 0124, 62-68(1977).

    [11] Yang M Z, Zou Y P, Zhang L et al. Correction to nonlinearity in interferometric data and its effect on radiometric calibration[J]. Chinese Journal of Lasers, 44, 0110002(2017).

    [12] Zhao M J, Si F Q, Lu Y H et al. Spectral image correction method for space-born differential optical absorption spectrometer[J]. Acta Optica Sinica, 35, 1230002(2015).

    [13] Nguyen T, Musca C A, Dell J M et al. Dark currents in long wavelength infrared HgCdTe gated photodiodes[J]. Journal of Electronic Materials, 33, 621-629(2004). http://link.springer.com/article/10.1007/s11664-004-0057-2

    Song Ye, Yongfeng Sun, Zhiwei Li, Hailiang Shi, Wei Xiong, Xinqiang Wang, Jiejun Wang, Wentao Zhang. [J]. Acta Optica Sinica, 2018, 38(6): 0612007
    Download Citation