• Acta Optica Sinica
  • Vol. 36, Issue 12, 1215005 (2016)
Lü Yaowen1、*, Liu Wei2, Xu Xiping1, and An Zhe1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/aos201636.1215005 Cite this Article Set citation alerts
    Lü Yaowen, Liu Wei, Xu Xiping, An Zhe. A Novel Camera One-Dimensional Calibration Method[J]. Acta Optica Sinica, 2016, 36(12): 1215005 Copy Citation Text show less
    References

    [1] Tsai R Y. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off the-shelf TV cameras and lenses[J]. IEEE Journal of Robotics and Automation, 1987, 3(4): 323-344.

    [2] Lü Yaowen, Wang Jianli, Cao Jingtai, et al. Monocular measurement for point target with parabolic motion[J]. Acta Optica Sinica, 2013, 33(6): 0615001.

    [3] Zhang Yueqiang, Su Ang, Liu Haibo, et al. Pose estimation based on multiple line hypothesis and iteratively reweighted least squares[J]. Optics and Precision Engineering, 2015, 23(6): 1722-1731.

    [4] Oh H, Won D, Huh S, et al. Indoor UAV control using multi-camera visual feedback[J]. Journal of Intelligent & Robotic Systems, 2011, 61(1-4): 57-84.

    [5] Zhang Z. A flexible new technique for camera calibration[J]. IEEE Transactions on Pattern Analysis & Machine Intelligence, 2000, 22 (11): 1330-1334.

    [6] Zhang Z Y. Camera calibration with one-dimensional objects[J]. IEEE Transactions on Pattern Analysis & Machine Intelligence, 2004, 26(7): 892-899.

    [7] Hartley R I, Zisserman A. Multiple view geometry in computer vision[M]. Second edtion. Cambridge: Cambridge University Press, 2004: 223-229, 104-109.

    [8] Hammarstedt P, Sturm P, Heyden A. Degenerate cases and closed-form solutions for camera calibration with one-dimensional objects[C]. Proceedings of the Tenth IEEE International Conference on Computer Vision, 2005, 1: 317-324.

    [9] Wu F C, Hu Z Y, Zhu H J. Camera calibration with moving one dimensional objects[J]. Pattern Recognition, 2005, 38(5): 755-765.

    [10] Frana J A de, Stemmer M R, Frana M B de M, et al. Revisiting Zhang′s 1D calibration algorithm[J]. Pattern Recognition, 2010, 43(3): 1180-1187.

    [11] Shi K, Dong Q, Wu F. Weighted similarity-invariant linear algorithm for camera calibration with rotating 1D objects[J]. IEEE Transactions on Image Processing, 2012, 21(8): 3806-3812.

    [12] Shi Kunfeng, Wu Fuchao. Optimally weighted linear algorithm for camera calibration with 1D objects[J]. Journal of Computer-Aided Design & Computer Graphics, 2014, 26(8): 1251-1257.

    [13] Qi F, Li Q, Luo Y, et al. Constraints on general motions for camera calibration with one dimensional objects[J]. Pattern Recognition, 2007, 40(6): 1785-1792.

    [14] Frana J A de, Stemmer M R, Frana M B de M, et al. A new robust algorithmic for multi-camera calibration with a 1D object under general motions without prior knowledge of any camera intrinsic parameter[J]. Pattern Recognition, 2012, 45(10): 3636-3647.

    [15] Fu Zhongliang, Zhou Fan, Xie Yanfang, et al. One-dimensional multi-camera calibration based on fundamental matrix[J]. Acta Optica Sinica, 2013, 33(6): 0615003.

    [16] He X, Zhang H, Hur N, et al. Complete camera calibration using line-shape objects[C]. Tencon 2006 Hong Kong IEEE Region 10 Conference, 2006: 1-4.

    [17] Wang Bo, Sun Fengmei. 1D camera calibration revisited[J]. Journal of Computer-Aided Design & Computer Graphics, 2014, 26(3): 452-456.

    [18] Xue Junpeng, Su Xianyu. Camera calibration with single image based on two orthogonal one-dimensional objects[J]. Acta Optica Sinica, 2012, 32(1): 0115001.

    [19] Hong Yang, Sun Xiuxia, Cai Ming, et al. An intrinsic parameters self-calibration technique based on infinite homography between orthogonal vanishing points[J]. Chinese J Lasers, 2015, 42(12): 1208001.

    [20] Triggs B. Auto calibration from planar scenes[C]. Proceedings of European Conference on Computer Vision, 1998, 1406: 89-105.

    [21] Bouguet J Y. Camera calibration toolbox for Matlab[EB/OL]. (2015-10-14)[2016-05-20]. http://vision.caltech.edu/bouguetj/calib_doc/index.html.

    CLP Journals

    [1] Fan Yang, Cheng Han, Baoxing Bai, Chao Zhang. Research on Parameter Calibration of Projection Correction System[J]. Acta Optica Sinica, 2018, 38(1): 0115001

    [2] Yaowen Lü, Wei Liu, Bojun Du, Xipin Xu. Further Study and Application for One-Dimensional Homography Matrix[J]. Acta Optica Sinica, 2018, 38(7): 0715003

    [3] Cong Sun, Haibo Liu, Shengyi Chen, Yang Shang. A General Imaging Model Based Method for Scheimpflug Camera Calibration[J]. Acta Optica Sinica, 2018, 38(8): 0815009

    [4] Zhai Liang, Wang Tao, Bai Manshe, Zuo Yijuan, Su Yu, Liu Xin, Chen Jing, Zhu Liangjian. Real-Time Loss Measurement of Reflecting Mirrors Applied in Plasma Environment[J]. Acta Optica Sinica, 2017, 37(7): 712001

    Lü Yaowen, Liu Wei, Xu Xiping, An Zhe. A Novel Camera One-Dimensional Calibration Method[J]. Acta Optica Sinica, 2016, 36(12): 1215005
    Download Citation