• Opto-Electronic Engineering
  • Vol. 40, Issue 8, 73 (2013)
HENG Peiyin*, ZHANG Chunyuan, JIA Yannan, and DONG Wei
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3969/j.issn.1003-501x.2013.08.013 Cite this Article
    HENG Peiyin, ZHANG Chunyuan, JIA Yannan, DONG Wei. Error Analysis of Image Acquisition Flux-cored Online Detector Medicine Based on Area Array CCD[J]. Opto-Electronic Engineering, 2013, 40(8): 73 Copy Citation Text show less

    Abstract

    A set of online drug type based on array CCD detector is designed. On this basis, the basic principle of medicine online detection system is introduced. In this paper, from the three aspects: perspective error, light error, the positioning error, the cause of the error in the image acquisition process is found through theoretical analysis and experimental research. And then, the corresponding solutions are proposed, thus the measurement precision of on-line detecting instrument is greatly improved.
    HENG Peiyin, ZHANG Chunyuan, JIA Yannan, DONG Wei. Error Analysis of Image Acquisition Flux-cored Online Detector Medicine Based on Area Array CCD[J]. Opto-Electronic Engineering, 2013, 40(8): 73
    Download Citation