• Laser & Optoelectronics Progress
  • Vol. 57, Issue 13, 132201 (2020)
Mingchun Feng1、*, Liang Xu2, and Yujie Wang1
Author Affiliations
  • 1School of Mechanical and Electrical Engineering, Chuzhou University, Chuzhou, Anhui 239000, China
  • 2Key Laboratory of Environment Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei, Anhui 230031, China
  • show less
    DOI: 10.3788/LOP57.132201 Cite this Article Set citation alerts
    Mingchun Feng, Liang Xu, Yujie Wang. Collimation Factors and Performance Analysis Based on Michelson Interferometer[J]. Laser & Optoelectronics Progress, 2020, 57(13): 132201 Copy Citation Text show less
    References

    [1] Griffiths P R, de Haseth J A. Fourier transform infrared spectrometry[M]. 2nd ed. Hoboken: John Wiley & Sons, Inc.(2007).

    [2] Wu J G[M]. Fourier transform infrared spectroscopy and its application in modern times, 1(1994).

    [3] Saptari V. Fourier-transform spectroscopy instrumentation engineering[M]. Bellingham: SPIE(2003).

    [4] Johnston S F. Fourier transform infrared: a constantly evolving technology[M]. New York: Ellis Horwood(1991).

    [5] Dublin Philosophical Magazine, Journal of Science[J]. Michelson A A. Visibility of interference-fringes in the focus of a telescope. The London, Edinburgh, 31, 256-259(1891).

    [6] Michelson A A[M]. Light waves and their uses(1903).

    [7] Bell R J[M]. Introductory Fourier transform spectroscopy(1972).

    [8] Lin K F. Optical alignment of a far-infrared Michelson interferometer[J]. Applied Optics, 20, 722-723(1981).

    [9] Comolli L, Saggin B. Evaluation of the sensitivity to mechanical vibrations of an IR Fourier spectrometer[J]. Review of Scientific Instruments, 76, 123112(2005).

    [10] Bai S J, Hou L Z, Ke J Y. The influence of micro-vibration on space-borne Fourier transform spectrometers[J]. Proceedings of SPIE, 9298, 92980I(2014).

    [11] Yanagisawa T, Akiyama T, Tamagawa Y et al. Influence of vibrations on Fourier transform spectrometers[J]. Proceedings of SPIE, 3221, 429-436(1997).

    [12] Toon G C, Wunch D, Wennberg P. Correction of ghosts in FTIR spectra[C]. OSA Fourier Transform Spectroscopy, March 1-4, 2015, Lake Arrowhead, California, USA., FW3A, 6(2015).

    [13] Saggin B, Comolli L, Formisano V. Mechanical disturbances in Fourier spectrometers[J]. Applied Optics, 46, 5248-5256(2007).

    [14] Shatalina I, Frederic S, Bortolino S et al. Analytical model and spectral correction of vibration effects on Fourier transform spectrometer[J]. Proceedings of SPIE, 8890, 88900S(2013).

    [15] Feng M C, Xu L, Jin L et al. Tilt and dynamic alignment for the moving mirror in the Fourier transform infrared spectrometer[J]. Acta Photonica Sinica, 45, 0412005(2016).

    [16] Yu L M, Dai Z X, Wang M C et al. Adaptive alignment of fixed mirror by phase detection[J]. Optics and Precision Engineering, 11, 448-452(2003).

    [17] Kuang C F, Feng Q B, Feng J Y et al. Analyzing characteristic of the four-quadrant detector applied to laser alignment[J]. Optical Technique, 30, 387-389(2004).

    Mingchun Feng, Liang Xu, Yujie Wang. Collimation Factors and Performance Analysis Based on Michelson Interferometer[J]. Laser & Optoelectronics Progress, 2020, 57(13): 132201
    Download Citation