
- Advanced Imaging
- Vol. 2, Issue 1, 015001 (2025)
Abstract
Keywords
1. Introduction
Single-shot high-speed mapping photography is indispensable for observing transient physical, chemical, and biological processes during their occurrence, offering critical insights into the underlying mechanisms governing these events[1–4]. This approach assigns time-gated frames of a dynamic scene to separate spatial positions so that they can be captured by one or more two-dimensional (2D) detectors. It effectively circumvents the limitations of high-speed burst charge-coupled device (CCD) sensors and cameras[5] and computational high-speed imaging techniques such as compressive multi-aperture complementary metal-oxide-semiconductor (CMOS) image sensors and compressed optical-streaking cameras[6–8], which often struggle with challenges related to the low fill factor of image sensors and/or the complexity of sophisticated image reconstruction algorithms. Single-shot high-speed mapping photography can be classified into the categories of active illumination[9] and passive detection[10]. Although the capabilities of these two approaches can often be highly complementary, both also suffer from high technical requirements. Active illumination-based methods typically require complex system configurations to transfer temporal information to other domains, such as the optical spectrum[11,12], illumination angle[13], spatial position[14,15], and/or spatial frequency[16,17] either at the illumination source or receiving sensor. Consequently, the elimination of specialized illumination is an attractive feature of passive detection-based approaches that use receive-only ultrafast detectors[18]. To this end, the passive implementation of time-gating and image mapping is often achieved through the introduction of multiple sensors and/or active optical elements, with examples including rotating steering mirrors combined with a CCD camera array[19], multiple beam splitters combined with intensified CCD cameras[20], and the use of image-convertor streak tubes[21]. However, the introduction of multiple sensors and/or active elements often leads to passive detection-based methods to face challenges in light throughput and cost efficiency.
Among recent advancements, a noticeable development is diffraction-gated real-time ultrahigh-speed mapping (DRUM) photography[22]. Using the inter-pattern transition of a digital micromirror device (DMD)[23–27], DRUM photography leverages a sweeping optical diffraction envelope as a nanosecond-level time gate to sequentially extract frames at different time points from distinct diffraction orders. The system can capture a transient event in a single exposure at 4.8 million frames per second (Mfps) and a sequence depth of 7 frames.
Even with these attractive features, the technical specifications of DRUM photography have the potential for improvement. Currently, DRUM photography only records diffraction orders distributed along a single horizontal axis, thus limiting its sequence depth and imaging speed. More significantly, only transitions between uniform DMD patterns (i.e., “all-on” or “all-off”) have so far been employed for diffraction gating in DRUM photography, a restriction that imposes an intensity-only image contrast while also overlooking the DMD’s ability to serve as a programmable spatial filter[28,29].
Sign up for Advanced Imaging TOC. Get the latest issue of Advanced Imaging delivered right to you!Sign up now
To overcome these limitations, we develop DRUM schlieren (DRUMS) photography. First, by leveraging information from both on-axis and off-axis diffraction orders, DRUMS photography doubles the sequence depth and imaging speed of DRUM photography. Second, by recognizing the DMD as a dual-purpose device for both nanosecond-level diffraction gating and Fourier plane spatial filtering, DRUMS photography introduces schlieren imaging[30–32] capabilities to the DRUM photography platform for ultrahigh-speed image acquisition. Benefiting from this ultrahigh-speed schlieren imaging ability, we apply DRUMS photography to the real-time observation of laser-induced breakdown in distilled water.
2. Operating Principle of DRUMS Photography
2.1. System
The DRUMS photography system is schematically illustrated in Fig. 1(a). A 473 nm continuous-wave laser (CNI, MSL-FN-473) serves as the illumination source for probing a transient scene. After passing through front optics chosen to suit the desired field of view (FOV), the transmitted light is reflected by a beam splitter (Thorlabs, BP250) to form an image of the transient scene on the intermediate image plane (IIP). The image is processed by a folded
Figure 1.Schematic of DRUMS photography. (a) Schematic of the system. (b) Schematic of the DMD micromirror array, regarded as the combination of two rectangular grids of pitch
2.2. Derivation of DRUMS image formation
In the following, we assume a unit magnification of the stereoscopic objective lens and the perfect synchronization of the micromirrors’ flipping motion. We also ignore aberrations and the finite numerical aperture of the objective lens and relay system. The image of the transient scene created at the IIP by the front optics and beamsplitter is denoted by
Here,
The function
After reflection from the DMD, the stereoscopic lens induces another Fourier transform, mapping the DMD plane to the IIP. Subsequently, the complex field at the IIP is expressed by
Equation (6) thus defines the image produced in the IIP as a 2D array of shifted copies of the schlieren image of the transient scene, each indexed according to integer diffraction order coordinates
Taking the squared modulus of Eq. (6) produces the time-dependent intensity signal
Equation (8) thus provides the foundation for DRUMS photography’s image acquisition, with the rapid time-dependent positioning of the
2.3. Key parameters
The sequence depth of DRUMS photography is governed by the spacing of diffraction orders on the IIP, together with the swept range of the
Assuming that the zero overlap occurs between images produced by adjacent diffraction orders, the FOV of DRUMS photography is determined by the magnification ratio of the front optics
By substituting the value
Stemming from the diffraction gating mechanism, the frame rate of DRUMS photography is determined by the time interval separating the arrival of the diffraction envelope’s peak intensity at adjacent diffraction orders along the
Making use of the small angle approximation, together with the assumption that the speed of mirror flipping
For our characterization of the framerate of DRUMS photography, the values of
3. Simulation of DRUMS Photography
We numerically simulated DRUMS photography using an animation of “Pacman” [Fig. 2(a)] as the ground truth scene. The animation consisted of 13 frames, each with dimensions of
Figure 2.Simulation of DRUMS photography. (a) Five representative frames of the ground truth dynamic scene. (b) Close-up phase profiles of the simulated DMD during mirror flipping, corresponding to the frames shown in (a). (c) 2D Fourier spectrum of Frame 7 with the portion of spatial frequencies blocked by the knife-edge filter shown by the green-dash-filled rectangle. (d) Simulated frames recorded by DRUMS photography corresponding to the frames and phase profiles shown, respectively, in (a) and (b). (e)–(f) Line profiles [shown by the light blue horizontal lines in (d)] of DRUMS photography (light blue solid line) and the ground truth (black dashed line) in Frame 1 (e) and Frame 10 (f).
For schlieren imaging, a knife-edge filter was applied to the 2D Fourier spectrum of each frame in the ground truth. As an example, Fig. 2(c) illustrates the 2D Fourier spectrum of Frame 7, with the blocked portion of the spectrum represented by the green-dash-filled rectangle. Each filtered spectrum, multiplied with the corresponding DMD modulation profile, was inversely Fourier transformed to produce the schlieren image. Five representative DRUMS photography results are depicted in Fig. 2(d), with the full animated sequence shown in Visualization 1.
To illustrate the effect of schlieren imaging, line profiles extracted from simulation results of Frame 1 and Frame 10 [shown by the light blue horizontal lines in Fig. 2(d)] are compared to the corresponding ground truth profiles in Figs. 2(e) and 2(f), respectively. As the line profiles show, the vertical orientation of the knife-edge, together with the blocking of the central DC component of the 2D Fourier spectrum, produces simulated schlieren images that isolate vertically oriented edge features in the ground truth.
4. Evaluation of System Performance
We positioned a negative USAF 1951 resolution target (Thorlabs, R3L1S4N) at the object plane under continuous-wave illumination to assess DRUMS photography’s spatial resolution. A representative non-schlieren image of the target recorded by DRUM photography is shown in Fig. 3(a), with the entire 13-frame sequence recorded by DRUMS photography shown in Fig. 3(b). The system can resolve Group 6 Element 2, corresponding to a spatial resolution of 7 µm. To illustrate the effect of knife-edge filtering by the DMD, line profiles [shown by the light blue line in Fig. 3(b)] extracted from images recorded by DRUM photography and DRUMS photography are presented in Fig. 3(c), corresponding to frames extracted by the
Figure 3.Characterization of the performance of DRUMS photography. (a) DRUM photography of the USAF 1951 resolution target under continuous-wave illumination. (b) DRUMS photography corresponding to the resolution target in (a). Close-up views show the details of Group 6 Element 2. (c) Comparison of line profiles of Group 4 Element 1 [shown by the light blue line in (b)] between DRUM photography (black dashed line) and DRUMS photography (blue solid light line). (d) DRUM photography of a fracture in a glass microscope slide under continuous-wave illumination modulated with a 50% duty cycle square wave at 2.5 Hz. (e) DRUMS photography corresponding to the scene in (d). (f) Time history of the normalized light intensity of the local region marked by a light blue rectangle in (e).
We then conducted proof-of-concept experiments by imaging a fracture defect of a glass microscope slide illuminated by the 473 nm light source modulated with a 2.5 Hz square wave with a 50% duty cycle. A bright-field image recorded by DRUM photography at
5. Observation of Laser-Induced Breakdown in Liquid
We employed DRUMS photography to investigate the interaction between femtosecond laser pulses and liquid water. In the experimental setup depicted in Fig. 4(a), a single pump pulse (1035 nm wavelength; 350 fs pulse duration; 7 µJ pulse energy) was generated by a femtosecond laser (Huaray, HR-Femto-10) and focused into distilled water contained in a glass cuvette using a lens with a 15 mm focal length (Thorlabs, LB1092). The tightly focused beam ionized the distilled water creating a plasma channel at the focus. Five representative frames recorded by DRUMS photography of the refractive index perturbation caused by the laser-induced breakdown are shown in Fig. 4(b), with the full evolution shown in Visualization 3. The time history of the channel length is illustrated in Fig. 4(c), showing that the channel initiates with a length of 434 µm at 0.23 µs and subsequently decreases to 70 µm at 1.23 µs.
Figure 4.DRUMS photography of laser-induced breakdown in distilled water. (a) Schematic of the experimental setup. (b) Selected DRUMS photography frames showing the evolution of the laser-induced plasma channel in distilled water using a 7 µJ pump pulse. (c) Time history of the channel length.
6. Conclusion and Discussion
We have developed DRUMS photography, a single-shot 2D ultrahigh-speed schlieren imaging technique capable of a frame rate of 9.8 Mfps and a sequence depth of 13 frames. By leveraging the abilities afforded by a folded
DRUMS photography represents one of the fastest schlieren photography systems. Unlike existing setups in this category[39,40], DRUMS photography is developed upon the normal operation of a camera. It retains the advantage of high sensitivity in many scientific-grade cameras (e.g., electron-multiplying CCD cameras and scientific CMOS cameras) and endows them with ultrahigh imaging speeds. In contrast to computational high-speed imaging techniques that employ spatial domain encoding and reconstruction algorithms for the recovery of transient scenes, DRUMS photography avoids the computational overheads associated with compressive reconstruction, as well as the limitations in spatial resolution imposed by the use of spatial domain coded apertures and the inherently ill-posed nature of inverse problems confronted by such techniques in recovering high-dimensionality datasets from low-dimensionality information. Moreover, implemented in a single camera, DRUMS photography embodies a compact and cost-efficient system compared to its counterparts requiring multiple cameras and/or active optical elements[41,42]. Furthermore, the programmable nature of the deployed DMD—as a coded 2D dynamic blazed grating[43]—permits the customization of imaging parameters tailored to specific experimental requirements, further enhancing the system’s adaptability. In terms of repeatability and long-term stability, DRUMS photography benefits directly from the well-established reliability and robustness of DMD hardware, with demonstrated operation lifetimes exceeding 100,000 h and 3 trillion display cycles[44]. Benefitting from a non-mechanical knife-edge filter, DRUMS photography features high accuracy and flexibility in system alignment and calibration. Finally, considering the broad responsive spectrum of the DMD, DRUMS photography possesses high adaptability to dynamic scenes at different wavelengths.
Future work will be carried out in the following three aspects. First, we plan to further enhance the system’s imaging speed using micro-electro-mechanical system technology with a shorter inter-pattern transition[45]. Second, although demonstrated only for schlieren imaging, DRUMS photography could be applied to phase-sensitive microscopy by loading a rotationally symmetric filter on the DMD[46]. Finally, we plan to apply DRUMS photography to study the impact of tissue heterogeneity on laser ablation for minimally invasive surgeries[47].
References
[5] L. Lazovsky et al. CCD sensor and camera for 100 Mfps burst frame rate image capture. Proc. SPIE, 5787, 184-190(2005).
[8] Y. Lai et al. Tutorial on compressed ultrafast photography. J. Biomed. Opt., 29, S11524(2024).
[10] J. Liang, L. V. Wang. Single-shot ultrafast optical imaging. Optica, 5, 1113(2018).
[26] D. M. Benton. Multispectral lidar using a two-dimensional dynamic diffraction grating: how to get nanosecond resolution from a projector and a camera. Proc. SPIE, 13200, 58-67(2024).
[31] G. S. Settles. Schlieren and Shadowgraph Techniques(2001).
[34] T.-H. Chao, H. Zhou, G. F. Reyes. Compact 512 × 512 grayscale optical correlator. Proc. SPIE, 4734, 9-12(2002).
[35] H. Zhou et al. On the development of filter management module for grayscale optical correlator. Proc. SPIE, 5437, 87-94(2004).
[36] T.-H. Chao et al. High-speed optical processing using digital micromirror device. Proc. SPIE, 9094(2014).
[41] J. Zheng et al. A high-performance visible framing ICCD camera base on the image intensifier. 2023 24th International Conference on Electronic Packaging Technology (ICEPT), 5(2023).
[44] M. Douglass. DMD reliability: a MEMS success story. Proc. SPIE, 4980(2003).

Set citation alerts for the article
Please enter your email address