• Infrared and Laser Engineering
  • Vol. 50, Issue 8, 20210279 (2021)
Yufan Hao, Zhengyun Feng, Chao Han, Zeyun Wang, Qingfang Wang, Liping Wang, Chenjun Shi, Xu Wu, and Yan Peng
Author Affiliations
  • College of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
  • show less
    DOI: 10.3788/IRLA20210279 Cite this Article
    Yufan Hao, Zhengyun Feng, Chao Han, Zeyun Wang, Qingfang Wang, Liping Wang, Chenjun Shi, Xu Wu, Yan Peng. Application of high sensitive detection sensor chip in detection of brain glioma disease[J]. Infrared and Laser Engineering, 2021, 50(8): 20210279 Copy Citation Text show less
    (a) THz characteristic spectrum of MI; (b) THz characteristic spectrum of GABA. The error bars are marked on the curves in blue
    Fig. 1. (a) THz characteristic spectrum of MI; (b) THz characteristic spectrum of GABA. The error bars are marked on the curves in blue
    (a) Structure parameters of THz resonant ring chip; (b) Structure multiple layout drawings; (c) Theoretical map data; (d) The normalized electric field distribution calculating by COMSOL
    Fig. 2. (a) Structure parameters of THz resonant ring chip; (b) Structure multiple layout drawings; (c) Theoretical map data; (d) The normalized electric field distribution calculating by COMSOL
    Physical test of THz resonant ring chip. (a) Partial structural photos of metamaterial chip under microscope (200×); (b) THz spectrum measured by the chip. The error bar is marked on the curve in grey
    Fig. 3. Physical test of THz resonant ring chip. (a) Partial structural photos of metamaterial chip under microscope (200×); (b) THz spectrum measured by the chip. The error bar is marked on the curve in grey
    Testing results of MI. (a) Terahertz spectra of MI covered metamaterial chips with different concentrations; (b) The change of formant frequency shift of chip under different concentration of MI. The error bars are marked on the curves/points
    Fig. 4. Testing results of MI. (a) Terahertz spectra of MI covered metamaterial chips with different concentrations; (b) The change of formant frequency shift of chip under different concentration of MI. The error bars are marked on the curves/points
    Testing results of GABA. (a) Terahertz spectra of metamaterial chips covered with different concentrations of GABA; (b) The change of formant frequency shift of chip under different concentrations of GABA.The error bars are marked on the curves/points
    Fig. 5. Testing results of GABA. (a) Terahertz spectra of metamaterial chips covered with different concentrations of GABA; (b) The change of formant frequency shift of chip under different concentrations of GABA.The error bars are marked on the curves/points
    Yufan Hao, Zhengyun Feng, Chao Han, Zeyun Wang, Qingfang Wang, Liping Wang, Chenjun Shi, Xu Wu, Yan Peng. Application of high sensitive detection sensor chip in detection of brain glioma disease[J]. Infrared and Laser Engineering, 2021, 50(8): 20210279