• Acta Optica Sinica
  • Vol. 40, Issue 3, 0312001 (2020)
Xuebin Wang1、2、*, Wei Dong2、**, Mei Yang3, Bowen Zhang2, and Bin Yu2
Author Affiliations
  • 1Institute of Computational Mechanics, Liaoning Technical University, Fuxin, Liaoning 123000, China
  • 2School of Mechanics & Engineering, Liaoning Technical University, Fuxin, Liaoning 123000, China;
  • 3School of Mechanical Engineering, Liaoning Technical University, Fuxin, Liaoning 123000, China
  • show less
    DOI: 10.3788/AOS202040.0312001 Cite this Article Set citation alerts
    Xuebin Wang, Wei Dong, Mei Yang, Bowen Zhang, Bin Yu. Inhomogeneous Strain Measurement Based on Least Absolute Deviation Fitting for Digital Image Correlation[J]. Acta Optica Sinica, 2020, 40(3): 0312001 Copy Citation Text show less
    Schematic of DIC method
    Fig. 1. Schematic of DIC method
    Simulated speckle images. (a) Reference image;(b) shear band image with strain gradient
    Fig. 2. Simulated speckle images. (a) Reference image;(b) shear band image with strain gradient
    Evolutions of E1 and fitting coefficient with N
    Fig. 3. Evolutions of E1 and fitting coefficient with N
    Distributions of average γxy. (a) Measuring point interval is 4 pixel; (b) measuring point interval is 2 pixel; (c) measuring point interval is 1 pixel
    Fig. 4. Distributions of average γxy. (a) Measuring point interval is 4 pixel; (b) measuring point interval is 2 pixel; (c) measuring point interval is 1 pixel
    Errors of average γxy. (a) Measuring point interval is 4 pixel; (b) measuring point interval is 2 pixel; (c) measuring point interval is 1 pixel
    Fig. 5. Errors of average γxy. (a) Measuring point interval is 4 pixel; (b) measuring point interval is 2 pixel; (c) measuring point interval is 1 pixel
    Similar material model
    Fig. 6. Similar material model
    γmax of least square fitting for different Δx. (a) Δx=140; (b) Δx=300; (c) Δx=400
    Fig. 7. γmax of least square fitting for different Δx. (a) Δx=140; (b) Δx=300; (c) Δx=400
    γmax of least absolute deviation fitting for different Δx. (a) Δx=140; (b) Δx=300; (c) Δx=400
    Fig. 8. γmax of least absolute deviation fitting for different Δx. (a) Δx=140; (b) Δx=300; (c) Δx=400
    Distributions of γmax in monitoring line for different Δx. (a) Δx=140; (b) Δx=300; (c) Δx=400
    Fig. 9. Distributions of γmax in monitoring line for different Δx. (a) Δx=140; (b) Δx=300; (c) Δx=400
    Measuring point interval /pixelLeast absolute deviation fitting /sLeast square fitting /s
    46.740.13
    227.520.50
    1112.182.06
    Table 1. Comparison of time consumption of two methods
    Xuebin Wang, Wei Dong, Mei Yang, Bowen Zhang, Bin Yu. Inhomogeneous Strain Measurement Based on Least Absolute Deviation Fitting for Digital Image Correlation[J]. Acta Optica Sinica, 2020, 40(3): 0312001
    Download Citation