• Journal of Infrared and Millimeter Waves
  • Vol. 39, Issue 5, 553 (2020)
Li-Min WU1、2, Bin LIAO3, De-Gang XU1、2, Yu-Ye WANG1、2、3、*, Mei-Lan GE1、2, Chao-Nan ZHANG4, Jia-Hua LI4, Zhong-Cheng SUN1、2, Tu-Nan CHEN3, Hua FENG3, and Jian-Quan YAO1、2
Author Affiliations
  • 1Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin300072, China
  • 2Key Laboratory of Optoelectronics Information Technology (Ministry of Education), Tianjin University, Tianjin300072, China
  • 3Institute of Neurosurgery, Southwest Hospital, Army Medical University, Chongqing;400038, China
  • 4School of Life Sciences, Tianjin Engineering Center of Micro-Nano Biomaterials, Tianjin University, Tianjin300072, China
  • show less
    DOI: 10.11972/j.issn.1001-9014.2020.05.004 Cite this Article
    Li-Min WU, Bin LIAO, De-Gang XU, Yu-Ye WANG, Mei-Lan GE, Chao-Nan ZHANG, Jia-Hua LI, Zhong-Cheng SUN, Tu-Nan CHEN, Hua FENG, Jian-Quan YAO. Study of in-vivo breast cancer in a subcutaneous xenograft mouse model using terahertz imaging[J]. Journal of Infrared and Millimeter Waves, 2020, 39(5): 553 Copy Citation Text show less
    References

    [1] A Jemal, R Siegel, J Xu et al. Cancer statistics, 2010. Ca-a cancer journal for clinicians, 60, 277-300(2010).

    [2] S A Feig, R E Hendrick. Radiation risk from screening mammography of women aged 40-49 years. Journal of the National Cancer Institute Monographs, 22, 119-124(1997).

    [3] N T Brewer, T Salz, S E Lillie. Systematic review: the long-term effects of false-positive mammograms. Annals of internal medicine, 146, 502-510(2007).

    [4] C S Joseph, R Patel, V A Neel et al. Imaging of ex vivo nonmelanoma skin cancers in the optical and terahertz spectral regions optical and terahertz skin cancers imaging. Journal of Biophotonics, 7, 295-303(2014).

    [5] M R Grootendorst, A J Fitzgerald, S G Koning et al. Use of a handheld terahertz pulsed imaging device to differentiate benign and malignant breast tissue. Biomedical Optics Express, 8, 2932-2945(2017).

    [6] Y B Ji, S J Oh, S G Kang et al. Terahertz reflectometry imaging for low and high grade gliomas. Scientific Reports 6, 36040(2016).

    [7] Y C Sim, J Y Park, K M Ahn et al. Terahertz imaging of excised oral cancer at frozen temperature. Biomedical Optics Express, 4, 1413-1421(2013).

    [8] M G Png, W J Choi, H W B Ng et al. The impact of hydration changes in fresh bio-tissue on THz spectroscopic measurements. Physics in Medicine and Biology, 53, 3501-3517(2008).

    [9] P Wesseling, M J Kros, J Jeuken. The pathological diagnosis of diffuse gliomas: towards a smart synthesis of microscopic and molecular information in a multidisciplinary context. Diagnostic Histopathology, 17, 486-494(2011).

    [10] K Meng, T N Chen, T Chen et al. Terahertz pulsed spectroscopy of paraffin-embedded brain glioma. Journal of Biomedical Optics, 19, 077001(2014).

    [11] S Yamaguchi, Y Fukushi, O Kubota et al. Origin and quantification of differences between normal and tumor tissues observed by terahertz spectroscopy. Physics in Medicine & Biology, 61, 6808-6820(2016).

    [12] G. Bindu, S. J. Abraham, A. Lonappan et al. Detection of dielectric contrast of breast tissues using confocal microwave technique. Microwave and Optical Technology Letters, 48, 1187-1190(2006).

    [13] P C Ashworth, E Pickwell-MacPherson, S E Pinder et al. Terahertz Spectroscopy of Breast Tumors(2007).

    [14] T Bowman, M E Shenaweea, L Campbellb. Regional spectroscopy of paraffin-embedded breast cancer tissue using pulsed terahertz transmission imaging(2016).

    [15] A M Hassan, D C Hufnagle, M E Shenawee et al. Terahertz imaging for margin assessment of breast cancer tumors(2012).

    [16] T Bowman, M E Shenawee, L K Campbell. Terahertz transmission vs reflection imaging and model-based characterization for excised breast carcinomas. Biomedical Optics Express, 7, 375-3783(2016).

    [17] T Bowman, A Walter, M El-Shenawee. Margin assessment of three-dimensional breast cancer phantoms using terahertz imaging(2016).

    [18] H Chen, T Chen, T Tseng et al. High-sensitivity in vivo THz transmission imaging of early human breast cancer in a subcutaneous xenograft mouse model. Optics Express, 19, 1-2(2011).

    [19] A Rahman, K A Rahman, B Rao. Early detection of skin cancer via terahertz spectral profiling and 3D imaging. Biosensors and Bioelectronics, 82, 64-70(2016).

    [20] V P Wallace, A J Fitzgerald, S Shankar et al. Terahertz pulsed imaging of basal cell carcinoma ex vivo and in vivo. British Journal of Dermatology, 151, 424-432(2004).

    [21] M E Shenawee, N Vohra, T Bowman et al. Cancer detection in excised breast tumors using terahertz imaging and spectroscopy. Biomedical Spectroscopy and Imaging, 8, 1-9(2019).

    Li-Min WU, Bin LIAO, De-Gang XU, Yu-Ye WANG, Mei-Lan GE, Chao-Nan ZHANG, Jia-Hua LI, Zhong-Cheng SUN, Tu-Nan CHEN, Hua FENG, Jian-Quan YAO. Study of in-vivo breast cancer in a subcutaneous xenograft mouse model using terahertz imaging[J]. Journal of Infrared and Millimeter Waves, 2020, 39(5): 553
    Download Citation