• Laser & Optoelectronics Progress
  • Vol. 58, Issue 19, 1926001 (2021)
Shuqiang Huang1, Xiumei Jiang1, and Yuanhua Feng2、3、*
Author Affiliations
  • 1Department of Optoelectronic Engineering, College of Science and Engineering, Jinan University, Guangzhou , Guangdong 510632, China
  • 2Department of Electronic Engineering, College of Information Science and Technology, Jinan University, Guangzhou , Guangdong 510632, China
  • 3State Key Laboratory of Integrated Optoelectronics, Beijing 100083, China
  • show less
    DOI: 10.3788/LOP202158.1926001 Cite this Article Set citation alerts
    Shuqiang Huang, Xiumei Jiang, Yuanhua Feng. Analysis of Phase Error of Retarders in Spectrally Encoded Mueller Matrix Measurement[J]. Laser & Optoelectronics Progress, 2021, 58(19): 1926001 Copy Citation Text show less
    Schematic of experimental setup of spectrally encoded Mueller matrix measurement system
    Fig. 1. Schematic of experimental setup of spectrally encoded Mueller matrix measurement system
    Measurement spectrum with 0° polarizer as sample
    Fig. 2. Measurement spectrum with 0° polarizer as sample
    Influence of phase ϕw on the Mueller matrix for different samples
    Fig. 3. Influence of phase ϕw on the Mueller matrix for different samples
    The value of each element of the Muller matrix with the compensation of polarizer from 0° to 90°
    Fig. 4. The value of each element of the Muller matrix with the compensation of polarizer from 0° to 90°
    ϕ2 /radϕ3 /radϕ4 /radERMS of vacuumERMS of polarizer(θ=45°ERMS of quarter waveplate(θ=45°
    Without compensationWith compensationWithout compensationWith compensationWithout compensationWith compensation
    0.01000.00300.00130.00400.00240.00510.0023
    0.1000.03300.00130.03510.00240.03660.0023
    00.0100.00300.00130.00400.00240.00450.0023
    00.100.03300.00130.03510.00240.03580.0023
    000.010.00300.00130.00400.00240.00510.0023
    000.10.03300.00130.03510.00240.04360.0023
    0.010.010.010.01060.00130.00790.00240.00930.0023
    0.10.10.10.10830.00130.07900.00240.08360.0023
    0.10.1-0.10.04320.00130.03550.00240.04440.0023
    Table 1. Influence of Δϕ2,Δϕ3,and Δϕ4 on the Mueller matrix for different samples and the compensation effect
    SampleTheoretical Muellermatrix

    Experimental Mueller

    matrix

    Mueller matrix element error
    Without compensationWith compensationERMSEmax
    Vacuum10000100001000011.00000.0431-0.05180.14400.04390.97740.01420.00950.02650.02610.8505-0.33770.01750.03510.33430.93011.00000.0487-0.0494-0.00190.04730.9899-0.0153-0.01430.0074-0.00710.9669-0.01060.03040.0431-0.06050.93140.03540.0686
    Polarizer 0°11001100000000001.00000.99220.00770.01290.98230.98200.0067-0.0048-0.03140.04050.04310.02860.0136-0.0157-0.01480.00351.00000.99430.02270.00940.98590.9838-0.0067-0.00580.01560.0003-0.06710.0537-0.02120.0070-0.0330-0.05970.01990.0471
    Polarizer 45°10100000101000001.00000.03621.2229-0.59370.0174-0.00430.0415-0.0556-0.1386-0.0399-0.1625-0.01541.39220.04921.4881-0.79761.00000.04110.99980.00800.0113-0.00610.00420.00351.05840.00561.0248-0.0449-0.00440.0332-0.04090.03240.02710.0584
    Quarter-wave plate 0°10000100000-100101.0000-20240.0630-0.07800.0266-0.0853-0.8329-0.30810.00130.42040.3130-0.62680.09580.9229-0.17800.74611.00000.0616-0.0022-0.06030.05840.98600.0181-0.00350.00140.04300.00411.01970.02360.0036-0.9539-0.06760.03890.0676
    Quarter-wave plate 90°10000100000-100101.00000.0564-0.16820.08250.04800.97690.01500.01020.00970.0028-0.4047-0.78830.00660.04000.8655-0.35181.00000.0651-0.02520.06120.05410.9911-0.01440.01260.0007-0.02430.0193-0.94520.00660.03190.96880.06300.03750.0630
    Half-wave plate 0°1000010000-10000-11.00000.08670.05370.16290.06760.98700.0020-0.0112-0.03230.0003-0.87320.3927-0.02600.0124-0.2852-0.93531.00000.06940.03940.01900.06250.99720.0020-0.0002-0.0054-0.0087-1.0308-0.0211-0.04080.00890.0340-0.95690.03250.0694
    Table 2. Comparison with and without compensation of different samples using polarizer method
    SampleTheoretical Mueller matrixExperimental Mueller matrix(with compensation)Mueller Matrix element error
    ERMSEmax
    Vacuum10000100001000011.00000.04540.0343-0.03810.04700.9905-0.0136-0.0137-0.0340-0.00760.97720.00860.04840.0406-0.07830.92810.03910.0783
    Polarizer 0°11001100000000001.00001.0015-0.03310.00760.98870.98590.0108-0.00390.00700.0156-0.04510.06980.02960.0231-0.0771-0.03650.03310.0698
    Half-wave plate 0°1000010000-10000-11.00000.0590-0.04900.05160.07070.99430.0066-0.00110.0383-0.0090-1.0275-0.0469-0.05340.01350.0423-0.95430.03960.0707
    Quarter-wave plate 0°10000100000-100101.00000.06580.03450.02940.05690.98700.0193-0.00240.01190.0418-0.01761.02810.06280.0074-0.9530-0.06350.03820.0658
    Table 3. Comparison of compensation results for different samples with 45° quarter-wave plate
    Shuqiang Huang, Xiumei Jiang, Yuanhua Feng. Analysis of Phase Error of Retarders in Spectrally Encoded Mueller Matrix Measurement[J]. Laser & Optoelectronics Progress, 2021, 58(19): 1926001
    Download Citation