• Opto-Electronic Engineering
  • Vol. 42, Issue 11, 13 (2015)
WANG Weiwen1、2、*, ZHOU Jin1, ZHANG Weili3, LIU Qinjuan3, and WU Qinzhang1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: 10.3969/j.issn.1003-501x.2015.11.003 Cite this Article
    WANG Weiwen, ZHOU Jin, ZHANG Weili, LIU Qinjuan, WU Qinzhang. Error Analysis of Long Distance External Parameter Calibration[J]. Opto-Electronic Engineering, 2015, 42(11): 13 Copy Citation Text show less
    References

    [1] ZHANG Zhengyou. A flexible new technique for camera calibration [J]. IEEE Transactions on Pattern Analysis and Machine Intelligence(S0162-8828),2000,22(11):1330-1334.

    [2] MA Songde. A self-calibration technique for active vision systems [J]. IEEE Transactions on Robotics and Automation (S1042-296X),1996,12(1):114-120.

    [3] LI Long,HE Mingyi,LI Na. Camera calibration based on the circular pattern and ellipse fitting [J]. Journal of Xidian University: Natural Science,2010,37(6):1148-1154.

    [4] JIANG Cheng,QU Shaowei,HU Hongyu,et al. Camera calibration based on pixel-angle reflection model [J]. Journal of Harbin Institute of Technology,2012,44(8):130-135.

    [5] SUN Qiucheng,DONG Xiaogang,LIU Ming,et al. An improved method of camera calibration [C]// IEEE 10th International Conference on Electronic Measurement & Instruments (ICEMI),Chengdu,China,Aug 16-19,2011:155-157.

    [6] DANIEL M,GABRIEL T. Simple,Accurate,and Robust Projector-Camera Calibration [C]// IEEE Second International Conference on 3D Imaging,Modeling,Processing,Visualization and Transmission(3DIMPVT),Zurich,Switzerland, Oct 13-15,2012:464-471.

    [7] ZHU Yunfang. Calibration of Radial Distortion and Intrinsic Parameters Using a Single Image [J]. Opto-Electronic Engineering,2012,39(9):125-131.

    [8] XIAO Zhitao,ZHANG Wenyin,GENG Lei,et al. Accuracy analysis of binocular vision system [J]. Opto-Electronic Engineering,2014,41(2):6-11.

    [9] LIU Fengcai,LI Aidi,MA Zezhong. Error analysis and parameter optimization of structured-light vision system [J]. Computer Engineering and Design,2013,34(2):758-761.

    [10] YANG Ming,WANG Haihui,CHEN Jun,et al. Method of accuracy improvement based on binocular calibration system [J]. Journal of Wuhan Institute of Technology,2012,34(1):69-73.

    [11] WANG Weiwen,YANG Wei,LUO Jian,et al. A new calibrating method of camera external parameters [J]. Semiconductor Optoelectronics,2014,35(6):1127-1130.

    CLP Journals

    [1] MEI Su, JIANG Zhiguo, HU Zongfu. Analysis on Error and Noise of Resonant Fiber Optic Gyros[J]. Semiconductor Optoelectronics, 2020, 41(1): 29

    WANG Weiwen, ZHOU Jin, ZHANG Weili, LIU Qinjuan, WU Qinzhang. Error Analysis of Long Distance External Parameter Calibration[J]. Opto-Electronic Engineering, 2015, 42(11): 13
    Download Citation