• Opto-Electronic Engineering
  • Vol. 42, Issue 11, 13 (2015)
WANG Weiwen1、2、*, ZHOU Jin1, ZHANG Weili3, LIU Qinjuan3, and WU Qinzhang1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: 10.3969/j.issn.1003-501x.2015.11.003 Cite this Article
    WANG Weiwen, ZHOU Jin, ZHANG Weili, LIU Qinjuan, WU Qinzhang. Error Analysis of Long Distance External Parameter Calibration[J]. Opto-Electronic Engineering, 2015, 42(11): 13 Copy Citation Text show less

    Abstract

    In order to overcome the difficulty during measuring the external parameters of the camera with a long object distance, a calibration target bar was used as a medium. Its precision can be verified by the binocular vision measurement. By means of analyses of the influence of the cooperative targets’ coordinate in the world coordinate system on the internal and external parameters of the camera, the influence of the measured cooperative targets’ coordinate by the binocular vision measurement can be determined. The result shows that the geodetic coordinate error of the cooperative targets in the calibration target bar can affect the measurement error of the measured cooperative targets. The result shows that, for the propose that the measurement precision requirements of the cooperative targets should reach 10 mm, the X axis precision requirement should be 0.621 9 mm, the Y axis is 13.341 2 mm, and the Z axis is 0.729 1 mm.
    WANG Weiwen, ZHOU Jin, ZHANG Weili, LIU Qinjuan, WU Qinzhang. Error Analysis of Long Distance External Parameter Calibration[J]. Opto-Electronic Engineering, 2015, 42(11): 13
    Download Citation