• Acta Optica Sinica
  • Vol. 36, Issue 9, 907001 (2016)
Zhou Liang1、2、*, Yu Jun1、2, Yang Tuo1、2, Zhu Tengfei1、2, Li Xiongchao1、2, Zou Yang1、2, Tang Shaotuo1、2, Luo Tongzheng1、2, Chen Guanxiao1、2, and Xu Ping1、2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/aos201636.0907001 Cite this Article Set citation alerts
    Zhou Liang, Yu Jun, Yang Tuo, Zhu Tengfei, Li Xiongchao, Zou Yang, Tang Shaotuo, Luo Tongzheng, Chen Guanxiao, Xu Ping. Analysis and Experimental Determination for Matched Filtering Recognition of Correlation Peak[J]. Acta Optica Sinica, 2016, 36(9): 907001 Copy Citation Text show less

    Abstract

    Whether correlators can output correlation peak is the main way to determine the target authenticity of correlators. However, it is prone to misjudgment when the accuracy of the components adjustment is not high enough. Based on the matched filtering correlators, we make theoretical analysis of three cases about the misjudgment of the correlation peaks. We give special emphasis to the theoretical and experimental study on correlation signal strength discrimination. Considering the three cases about the misjudgment of the correlation peaks, we explore the judgment of correlation peaks from the threshold intensity and the form of the correlation peaks, and the angle of rotation of the input image, which provide reference for experimental determination of the correlation peak.
    Zhou Liang, Yu Jun, Yang Tuo, Zhu Tengfei, Li Xiongchao, Zou Yang, Tang Shaotuo, Luo Tongzheng, Chen Guanxiao, Xu Ping. Analysis and Experimental Determination for Matched Filtering Recognition of Correlation Peak[J]. Acta Optica Sinica, 2016, 36(9): 907001
    Download Citation