• Acta Optica Sinica
  • Vol. 26, Issue 11, 1721 (2006)
[in Chinese]*, [in Chinese], [in Chinese], and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less
    DOI: Cite this Article Set citation alerts
    [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Influence of Wavefront Aberration of Single Zernike Modes on Optical Quality of Human Eyes[J]. Acta Optica Sinica, 2006, 26(11): 1721 Copy Citation Text show less
    References

    [5] Larry N. Thibos, Raymond A. Applegate, James T. Schwiegerling et al.. VSIA standards taskforce members. Standards for reporting the optical aberrations of eyes[J]. J. Refract. Surg., 2002, 18(5): S652~S660

    [6] Raymond A. Applegate, Edwin J. Sarver, Vic Khemsara. Are all aberrations equal [J]. J. Refract. Surg., 2002, 18(5): S556~S562

    [7] Raymond A. Applegate, Charles Ballentine, Hillery Gross et al.. Visual acuity as a function of Zernike mode and level of root mean square error[J]. Optometry and Vision Science, 2003, 80(2): 97~105

    [8] Raymond A. Applegate, Jason D. Marsack, Roberto Ramos et al.. Interaction between aberrations to improve or reduce visual performance[J]. J. Cataract. Refract. Surg., 2003, 29(8): 1487~1495

    [9] Jason D. Marsack, Larry N. Thibos, Raymond A. Applegate. Metrics of optical quality derived from wave aberrations predict visual performance[J]. J. Vis., 2004, 4(4): 322~328

    [10] Xu Cheng, Arthur Bradley, Larry N. Thibos. Predicting subjective judgment of best focus with objective image quality metrics[J]. J. Vis., 2004, 4(4): 310~321

    [11] Larry N. Thibos, Xin Hong, Arthur Bradley et al.. Accuracy and precision of objective refraction from wavefront aberrations[J]. J. Vis., 2004, 4(4): 329~351

    [12] Xu Cheng, Larry N. Thibos, Arthur Bradley. Estimating visual quality from wavefront aberration measurements[J]. J. Refract. Surg., 2003, 19(5): S579~S584

    [13] David A. Atchison, Susana Marcos, Dion H. Scott. The influence of the Stiles-Crawford peak location on visual performance[J]. Vision. Res., 2003, 43(6): 659~668

    CLP Journals

    [1] FANG Li-hua, HE Xing-dao, Li Shu-jing. Counterbalanced Relationship Between Defocus and Spherical Aberration Based on Optical Quality Metrics of Human Eyes[J]. Acta Photonica Sinica, 2010, 39(1): 110

    [2] Fang Lihua, He Xingdao, Chen Min. A New Method to Objective Refraction Based on the Curvature Distributions of Wave-front Aberrations Surface[J]. Acta Optica Sinica, 2010, 30(2): 485

    [3] Li Rui, Wang Zhaoqi, Liu Yongji, Kong Xiangming. Design of Corneal Contact Lens by Wavefront Technology[J]. Chinese Journal of Lasers, 2011, 38(s1): 116001

    [4] Fang Lihua, He Xingdao, Wang Yan, Gong Yongqing. Influence of Treatment Decentration on Wave-Front Aberration in Conventional Laser Refractive Surgery[J]. Acta Optica Sinica, 2010, 30(6): 1755

    [5] Tang Yuke, He Xiaohai, Tao Qingchuan. Research on the Point Spread Function of Microscope Based on the Zernike Polynomials[J]. Acta Optica Sinica, 2009, 29(1): 169

    [6] Mo Weidong, Fan Qi, Qu Shaobo, Feng Mingde, Yang Baiyu. Research on Algorithm and Reliability to Fit Interference Wave Surface with Zernike Polynomials[J]. Chinese Journal of Lasers, 2010, 37(S1): 267

    [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Influence of Wavefront Aberration of Single Zernike Modes on Optical Quality of Human Eyes[J]. Acta Optica Sinica, 2006, 26(11): 1721
    Download Citation