• Acta Optica Sinica
  • Vol. 37, Issue 11, 1111001 (2017)
Liangliang Zheng1、2、*, Guang Jin1, Hongsong Qu1, and Guixiang Zhang1
Author Affiliations
  • 1 Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin 130033, China
  • 2 University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.3788/AOS201737.1111001 Cite this Article Set citation alerts
    Liangliang Zheng, Guang Jin, Hongsong Qu, Guixiang Zhang. Non-Uniformity Correction for Multi-Channel TDI CCD Imaging System in Wide Response Range[J]. Acta Optica Sinica, 2017, 37(11): 1111001 Copy Citation Text show less
    Sketch map of a TDI CCD
    Fig. 1. Sketch map of a TDI CCD
    Signal processing flow of TDI CCD imaging system
    Fig. 2. Signal processing flow of TDI CCD imaging system
    Diagram of TDI CCD imaging system
    Fig. 3. Diagram of TDI CCD imaging system
    Response output of imaging system under 1/4 saturation. (a) Raw image data of 1/4 saturation; (b) gray distribution of 1/4 saturation
    Fig. 4. Response output of imaging system under 1/4 saturation. (a) Raw image data of 1/4 saturation; (b) gray distribution of 1/4 saturation
    Response output of imaging system under 1/2 saturation. (a) Raw image data of 1/2 saturation; (b) gray distribution of 1/2 saturation
    Fig. 5. Response output of imaging system under 1/2 saturation. (a) Raw image data of 1/2 saturation; (b) gray distribution of 1/2 saturation
    Response output of imaging system under 3/4 saturation. (a) Raw image data of 3/4 saturation; (b) gray distribution of 3/4 saturation
    Fig. 6. Response output of imaging system under 3/4 saturation. (a) Raw image data of 3/4 saturation; (b) gray distribution of 3/4 saturation
    Response output of imaging system calibrated by the proposed method under 1/2 saturation. (a) Raw image data of 1/2 saturation; (b) gray distribution of 1/2 saturation
    Fig. 7. Response output of imaging system calibrated by the proposed method under 1/2 saturation. (a) Raw image data of 1/2 saturation; (b) gray distribution of 1/2 saturation
    Luminance saturationPRNU /%
    Raw dataTwo-point correctionProposed method
    1/44.401.781.28
    1/24.091.930.85
    3/43.691.180.97
    Table 1. Correction results of PRNU
    Liangliang Zheng, Guang Jin, Hongsong Qu, Guixiang Zhang. Non-Uniformity Correction for Multi-Channel TDI CCD Imaging System in Wide Response Range[J]. Acta Optica Sinica, 2017, 37(11): 1111001
    Download Citation