• Acta Optica Sinica
  • Vol. 38, Issue 12, 1211003 (2018)
Jingjin Zhang1、2、*, Fangke Zong2, Baoguo Lei2, Baoping Guo1、2, and Qinlao Yang2、*
Author Affiliations
  • 1 College of Information Engineering, Shenzhen University, Shenzhen, Guangdong 518060, China
  • 2 Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen, Guangdong 518060, China
  • show less
    DOI: 10.3788/AOS201838.1211003 Cite this Article Set citation alerts
    Jingjin Zhang, Fangke Zong, Baoguo Lei, Baoping Guo, Qinlao Yang. Imaging of Large Format High Spatiotemporal Resolution X-Ray Streak Tube[J]. Acta Optica Sinica, 2018, 38(12): 1211003 Copy Citation Text show less
    Principle of streak camera
    Fig. 1. Principle of streak camera
    Photograph of large format streak tube
    Fig. 2. Photograph of large format streak tube
    Structural diagram of internal electrode in large format streak tube
    Fig. 3. Structural diagram of internal electrode in large format streak tube
    Structural diagram of reticle
    Fig. 4. Structural diagram of reticle
    Test results of static spatial resolution. (a) Image of left part of cathode; (b) image of right part of cathode
    Fig. 5. Test results of static spatial resolution. (a) Image of left part of cathode; (b) image of right part of cathode
    Schematic of dynamic test
    Fig. 6. Schematic of dynamic test
    Photograph of test-site
    Fig. 7. Photograph of test-site
    Test results of dynamic spatial resolution. (a) Image of spatial resolution; (b) maximum intensity of signal; (c) minimum intensity of signal
    Fig. 8. Test results of dynamic spatial resolution. (a) Image of spatial resolution; (b) maximum intensity of signal; (c) minimum intensity of signal
    Test results of dynamic temporal resolution. (a) Image of temporal resolution; (b) curve of signal intensity
    Fig. 9. Test results of dynamic temporal resolution. (a) Image of temporal resolution; (b) curve of signal intensity
    Test results of dynamic range. (a) Image of dynamic range; (b) maximum intensity of signal; (c) minimum intensity of signal
    Fig. 10. Test results of dynamic range. (a) Image of dynamic range; (b) maximum intensity of signal; (c) minimum intensity of signal
    Length of tube /mmDiameter of tube /mmLength of photocathode /mmDiameter of screen /mmMagnificationTotal voltage /kVDeflection sensitivity /(mm·kV-1)Radius of curvature of screen /mm
    60010050521.35126464
    Table 1. Structural parameters of large format streak tube
    ItemObject height /mm
    0.1510152025
    Position of image plane /mm598598597595590582
    Table 2. Optimal image plane position of electron beam for different object heights
    PhotocathodeGrid1st focus electrode1st anode2nd focus electrode2nd anode
    -12-1.474-6-1.474-10.2300
    Table 3. Each electrode voltage for experimental testkV
    ItemSpatial resolution /(lp·mm-1)
    1718192015161718
    Contrast degree /%42.140.135.133.330.233.132.621.4
    Limit spatial resolution /(lp·mm-1)3133323324262825
    Table 4. Limit spatial resolution of large format streak tube
    ParameterP2XSCProposed streak tube
    Total voltage /kV2012
    Limit spatial resolution(5%) /(lp·mm)2323
    Magnification1.081.35
    Effect length of photocathode /mm34.132
    Dynamic range6500(Channel)>2000
    Temporal resolution /ps33.3
    Number of CCD pixels /(pixel×pixel)4096×40962048×2048
    Area of CCD /(mm×mm)36.9×36.927×27
    Diameter of fluorescent screen /mm6252
    Sweep time /ns1.5,3.3,8.4,112,4,6,8
    Fluorescent powderP20P20
    Structure of screenSpherical screen(R64 mm)
    Total length of photocathode /mm5050
    Table 5. Comparison between proposed streak tube and P2XSC
    Jingjin Zhang, Fangke Zong, Baoguo Lei, Baoping Guo, Qinlao Yang. Imaging of Large Format High Spatiotemporal Resolution X-Ray Streak Tube[J]. Acta Optica Sinica, 2018, 38(12): 1211003
    Download Citation