• Acta Optica Sinica
  • Vol. 38, Issue 11, 1122004 (2018)
Shiliang Lou1、*, Jun Wu1、2, Zhitao Xiao1、2、*, Lei Geng1、2, Fang Zhang1、2, and Wen Wang1、2
Author Affiliations
  • 1 School of Electronics and Information Engineering, Tianjin Polytechnic University, Tianjin 300387, China
  • 2 Tianjin Key Laboratory of Optoelectronic Detection Technology and System, Tianjin 300387, China
  • show less
    DOI: 10.3788/AOS201838.1122004 Cite this Article Set citation alerts
    Shiliang Lou, Jun Wu, Zhitao Xiao, Lei Geng, Fang Zhang, Wen Wang. Optical System Design of Portable Stereoscopic Imaging Fundus Camera[J]. Acta Optica Sinica, 2018, 38(11): 1122004 Copy Citation Text show less
    Optical structure of fundus camera
    Fig. 1. Optical structure of fundus camera
    Two forms of stereomicroscope[4]. (a) Parallel optical path system; (b) Tilted optical path system
    Fig. 2. Two forms of stereomicroscope[4]. (a) Parallel optical path system; (b) Tilted optical path system
    Imaging system
    Fig. 3. Imaging system
    Optical characteristic curves of imaging system. (a) MTF curves; (b) field curvature and distortion curves; (c) chromatic aberration curves
    Fig. 4. Optical characteristic curves of imaging system. (a) MTF curves; (b) field curvature and distortion curves; (c) chromatic aberration curves
    MTF curves under different diopters
    Fig. 5. MTF curves under different diopters
    Illumination system
    Fig. 6. Illumination system
    Simulation results of illumination uniformity in fundus. (a) Annular spot near cornea; (b) on retina
    Fig. 7. Simulation results of illumination uniformity in fundus. (a) Annular spot near cornea; (b) on retina
    Simulated disparity map
    Fig. 8. Simulated disparity map
    Lens parameterRelationship between lens parameter and diopter A
    Anterior lens radius R3R3(A)=10.2-1.75·ln(A+1)
    Posterior lens radius R4R4(A)=-6+0.2294·ln(A+1)
    Aqueous thickness D2D2(A)=3.05-0.05·ln(A+1)
    Lens thickness D3D3(A)=4+0.1·ln(A+1)
    Lens refractive index n3n3(A)=1.42+9×10-5·(10·A+A2)
    Table 1. Expression of relationship between each lens parameter and human eye diopter
    Optical systemFocusing range /m-1ResolutionField curvature /mmDistortion /%
    Reported in reference [8]-10-+7>0.2 at 70 lp·mm-10.86-7.2
    Reported in reference [12]-10-+5>0.25 at 75 lp·mm-10.2-5
    Reported in reference [2]-15-+15>0.4 at 70 lp·mm-10.20.6
    Proposed-7-+5>0.55 at 70 lp·mm-10.028-4.9
    Table 2. Comparison among our designed optical system and other designs
    Shiliang Lou, Jun Wu, Zhitao Xiao, Lei Geng, Fang Zhang, Wen Wang. Optical System Design of Portable Stereoscopic Imaging Fundus Camera[J]. Acta Optica Sinica, 2018, 38(11): 1122004
    Download Citation