• Infrared and Laser Engineering
  • Vol. 45, Issue 11, 1117001 (2016)
Zhao Ziyue1、*, Zhu Jigui2, and Yang Linghui2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/irla201645.1117001 Cite this Article
    Zhao Ziyue, Zhu Jigui, Yang Linghui. Orientation parameters calibration of wMPS by using precise 3D coordinate control network[J]. Infrared and Laser Engineering, 2016, 45(11): 1117001 Copy Citation Text show less
    References

    [1] Yang Linghui, Zhu Jigui, Wei Zhenzhong, et al. Correction method for orientation parameters of workspace measurement positioning system[J]. Infrared and Laser Engineering, 2012, 41(6): 1629-1634. (in Chinese)

    [2] Zhou Weihu. Research on the precision theory of large-scale coordinate measuring systems[D]. Hefei: Hefei University of Technology, 2000. (in Chinese)

    [3] Duanmu Qiong, Yang Xueyou, Zhu Jigui, et al. 3D coordinate measurement system based on optoelectronic scanning [J]. Infrared and Laser Engineering, 2011, 40(10): 2014-2019. (in Chinese)

    [4] Yang Linghui, Yang Xueyou, Lao Dabao, et al. Large-scale coordinates measurement method based on intersection of optical planes[J]. Infrared and Laser Engineering, 2010, 39(6): 1105-1109. (in Chinese)

    [5] Ren Yongjie, Xue bin, Yang Linghui, et al. Study on the problem of weighting for the workspace measuring and positioning system[J]. Infrared and Laser Engineering, 2015, 44(2): 668-672. (in Chinese)

    [6] Lao Dabao, Yang Xueyou, Zhu Jigui, et al. Study on calibration technology of network laser scan space positioning system[J]. Chinese Journal of Mechanical Engineering, 2011, 47(6): 1-6. (in Chinese)

    [7] Xiong Z, Zhu J G, Xue B, et al. Typical deployments of workspace measurement and positioning system[J]. Optics & Precision Engineering, 2013, 21(9): 2354-2363. (in Chinese)

    [8] Peggs G N, Maropoulos P G, Hughes E B, et al. Recent developments in large-scale dimensional metrology[J]. Journal of Engineering Manufacture, 2009, 223: 571-595.

    [9] Ren Yongjie, Zhu Jigui, Wu Jun, et al. Self-calibration of workspace measurement and positioning system by using inter-scanning[J]. Optics & Precision Engineering, 2015, 3 (3): 609-616. (in Chinese)

    [10] Zhao Z, Zhu J, Xue B, et al. Optimization for calibration of large-scale optical measurement positioning system by using spherical constraint[J]. Journal of the Optical Society of America A Optics Image Science & Vision, 2014, 31(7):1427-1435.

    [11] Zhao Z Y, Zhu J G, Lin J R, et al. Transmitter parameter calibration of the workspace measurement and positioning system by using precise three-dimensional coordinate control network [J]. Optical Engineering, 2014, 53(8): 8.

    [12] Sun Hui. Target localization and error analysis of airborne electro-optical platform[J]. Chinese Optics, 2013, 6(6): 912-918. (in Chinese)

    [13] Xie Zexiao, Han Zhenghua, Gao Xiang, et al. Key technologies of monocular vision measurement system with light pen[J]. Chinese Optics, 2013, 5(5): 780-787. (in Chinese)

    Zhao Ziyue, Zhu Jigui, Yang Linghui. Orientation parameters calibration of wMPS by using precise 3D coordinate control network[J]. Infrared and Laser Engineering, 2016, 45(11): 1117001
    Download Citation