• Infrared and Laser Engineering
  • Vol. 49, Issue 2, 205005 (2020)
Xie Chenyu1、2、*, Zhai Wenchao1, Li Jianjun1, Gao Fang1、2, Li Yue1、2, Wu Haoyu1, and Zheng Xiaobing1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/irla202049.0205005 Cite this Article
    Xie Chenyu, Zhai Wenchao, Li Jianjun, Gao Fang, Li Yue, Wu Haoyu, Zheng Xiaobing. System-level spectral responsivity calibration comparison and validation of supercontinuum laser and monochromator[J]. Infrared and Laser Engineering, 2020, 49(2): 205005 Copy Citation Text show less
    References

    [1] Fan Bin, Chen Xu, Li Bicen, et al. Technical innovation of optical remote sensing payloads onboard GF-5 satellite[J]. Infrared and Laser Engineering, 2017, 46(1): 0102002. (in Chinese)

    [2] Zheng Xiaobing. High-accuracy radiometric calibration of satellite optical remote sensors[J]. Spacecraft Recovery & Remote Sensing, 2011, 32(5): 36-43. (in Chinese)

    [3] Brown S W, Eppeldauer G P, Lykke K R, et al. Facility for spectral irradiance and radiance responsivity calibrations using uniform sources[J]. Applied Optics, 2006, 45(32): 8218.

    [4] Schuster M, Nevas S, Sperling A, et al. Spectral calibration of radiometric detectors using tunable laser sources[J]. Applied Optics, 2012, 51(12): 1950.

    [5] Zhao Lei, Li Chao, Li Yue, et al. Hundred-watt-level supercontinuum spectrum generation based on photonic crystal fiber[J]. Chinese Journal of Lasers, 2017, 44(2): 0201018. (in Chinese)

    [6] Levick A P, Greenwell C L, Ireland J, et al. Spectral radiance source based on supercontinuum laser and wavelength tunable bandpass filter: the spectrally tunable absolute irradiance and radiance source[J]. Applied Optics, 2014, 53(16): 3508.

    [7] Yamaguchi Y, Yamada Y, Isshii J, et al. Supercontinuum source-based system for pre-launch calibration of the hyperspectral sensor[C]// SPIE, 2012, 8533: 85331K-1.

    [8] Yoo Y, Kim G, Park S, et al. Spectral responsivity calibration of the reference radiation thermometer at KRISS by using a super-continuum laser-based high-accuracy monochromatic source[J]. Metrologia, 2016, 53: 1354.

    [9] Wang Xiaoxun, Li Zhigang. Design and performance test of gershun tube spectral radiometer[J]. Acta Optica Sinica, 2017, 37(6): 0612002. (in Chinese)

    [10] Xu Qiuyun, Li Yanan, Zhai Wenchao, et al. Quantitative analysis of laser speckle removal[J]. Opto-Electronic Engineering, 2010, 37(5): 32-36. (in Chinese)

    [11] Zhang Yanna, Zheng Xiaobing, Li Jianjun, et al. Research on system level calibration method of multi-band filter radiometer[J]. Acta Optica Sinica, 2013, 33(8): 0812004. (in Chinese)

    [12] JJF 1059.1-2012 Evaluation and Expression of Uncertainty in Measurement[S]. 2012.

    [13] Louis-Philippe Boivin. Study of bandwidth effects in monochromator-based spectral responsivity measurements[J]. Applied Optics, 2002, 41(10): 1929-1935.

    [14] Yamaguchi Y, Yamada Y, Ishii J, et al. Supercontinuum-source-based facility for absolute calibration of radiation thermometers[J]. International Journal of Thermophysics, 2015, 36: 1825.

    Xie Chenyu, Zhai Wenchao, Li Jianjun, Gao Fang, Li Yue, Wu Haoyu, Zheng Xiaobing. System-level spectral responsivity calibration comparison and validation of supercontinuum laser and monochromator[J]. Infrared and Laser Engineering, 2020, 49(2): 205005
    Download Citation