• Photonic Sensors
  • Vol. 7, Issue 4, 350 (2017)
Lei ZHANG*, Xinlong CHANG, Youhong ZHANG, and Fan YANG
Author Affiliations
  • Xi’an Hi-Tech Institute, Xi’an, 710025, China
  • show less
    DOI: 10.1007/s13320-017-0423-3 Cite this Article
    Lei ZHANG, Xinlong CHANG, Youhong ZHANG, Fan YANG. Large Strain Detection of SRM Composite Shell Based on Fiber Bragg Grating Sensor[J]. Photonic Sensors, 2017, 7(4): 350 Copy Citation Text show less
    References

    [1] Z. H. Wang, G. P. Zhao, J. F. Ma, and J. X. Zheng, “Experiment study on the strain rate behavior of carbon/epoxy composite materials,” Acta Materiae Compositae Sinica, 2007, 24(2): 113–119.

    [2] R. S. Hyde, “A solid rocket motor manufacturer’s view of sensors and aging surveillance,” in Proc. of 37th Joint Propulsion Conference and Exhibit, Salt Lake City, 2001.

    [3] C. Davis, S. Tejedor, I. Grabovac, J. Kopczyk, and T. Nuyens, “High-strain fiber Bragg gratings for structural fatigue testing of military aircraft,” Photonic Sensors, 2012, 2(3): 215–224.

    [4] S. D. Siberstein, R. B. Lipton, S. Solomon, and N. T. Mathew, “Classification of daily and near-daily headaches: proposed revisions to the IHS criteria,” Headache the Journal of Head and Face Pain, 1994, 34(1):1–7.

    [5] J. Huang, X. W. Lan, H. Z. Wang, and H. Xiao, “Polymer optical fiber for large strain measurement based on multimode interference,” Optics Letters, 2012, 37(20): 4308–4310.

    [6] S. W. Kim, M. S. Jeong, I. Lee, E. Kim, I. B. Kwon, and T. K. Hwang, “Determination of the maximum strains experienced by composite structures using metal coated optical fiber sensors,” Composites Science and Technology, 2013, 78: 48–55.

    [7] D. Q. Ying, X. M. Tao, W. Zheng, and G. F. Wang, “Fabric strain sensor integrated with looped polymeric optical fiber with large angled v-shaped notches,” Smart Materials and Structures, 2013, 22(1): 1–11.

    [8] X. Y. Shen, “Study on the strain sensing and its enlarging technology based on fiber grating,” Ph.D. dissertation, Tianjin University, Tianjin, China, 2010.

    [9] J. Wu, H. P. Wu, J. B. Huang, and H. C. Gu, “Large range FBG sensor for ship structure health monitoring,” Optics and Precision Engineering, 2014, 22(2):311–317.

    [10] J. Huang, C. W. Liu, D. Wei, and L. I. Meng, “Discussion on large strain calibration method using FBG sensor,” Equipment Environmental Engineering, 2013, 10(4): 86–89.

    [11] D. Fuard, T. Tzvetkova-Chevolleau, S. Decossas, P. Tracqui, and P. Schiavone, “Optimization of poly-di-methyl-siloxane (PDMS) substrates for studying cellular adhesion and motility,” Microelectronic Engineering, 2008, 85(5–6): 1289–1293.

    [12] K. T. Wan, C. K. Y. Leung, and N. G. Olson, “Investigation of the strain transfer for surface-attached optical fiber strain sensors,” Smart Materials and Structures, 2008, 17(3):1–12.

    [13] L. Sun, C. Y. Yue, and Y. S. Song, “Strain transfer analysis of substrate fiber Bragg grating sensor,” Journal of Optoelectronics Laser, 2013, 24(5): 849–854.

    [14] W. W. Morey, G. Meltz, and W. H. Glenn, “Fiber optic Bragg grating sensors,” SPIE, 1990, 1169(96): 98–107.

    Lei ZHANG, Xinlong CHANG, Youhong ZHANG, Fan YANG. Large Strain Detection of SRM Composite Shell Based on Fiber Bragg Grating Sensor[J]. Photonic Sensors, 2017, 7(4): 350
    Download Citation