• Acta Optica Sinica
  • Vol. 31, Issue 11, 1112010 (2011)
Zhu Xianchang*, Wu Fan, Cao Xuedong, Wu Shibin, and Zhang Peng
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos201131.1112010 Cite this Article Set citation alerts
    Zhu Xianchang, Wu Fan, Cao Xuedong, Wu Shibin, Zhang Peng. Analysis of Focus Dislocation Induced by the Microlens Array Measuring Based on Grating Diffraction[J]. Acta Optica Sinica, 2011, 31(11): 1112010 Copy Citation Text show less
    References

    [1] Jiang Xiaoping, Liu Desen. Fabrication of gradient refractive index hexagonal aperture planar microlens array based on spherical substrate[J]. Acta Optica Sinica, 2010, 30(6): 1792~1795

    [2] Zhuang Xiaolei, Zhou Fang, Shen Su et al.. Characteristics of diffusers with cascaded-microlens arrays[J]. Acta Optica Sinica, 2010, 30(11): 3306~3310

    [3] Li Xiaogang, Chen Jimin, Liu Furong et al.. PMMA microlens array preparation using carbon dioxide laser[J]. Acta Optica Sinica, 2010, 30(s1): 100104

    [4] Geun Young Yoon, Takahisa Jitsuno, Masahiro Nakatsuka et al.. Shack-Hartmann wave-front measurement with a large F-number plastic microlens array[J]. Appl. Opt., 1996, 35(1): 188~192

    [5] Liu Desen, Hu Jianmin, Liu Xiaodong el al.. Studies on the optical properties of microlens array for planar intersect glasses waveguide[J]. Acta Photonica Sinica, 2003, 32(7): 782~785

    [6] He Miao, Yi Xinjian, Cheng Zuhai et al.. Research on fabrication and optical performance testing of silicon microlenses array with large F-number[J]. Chinese J. Lasers, 2000, 27(12): 1097~1102

    [7] Alam A. Camacho P., Cristina Solano, Giminiano Martinez-Ponce et al.. Simple method to measure the focal length of lenses[J]. Opt. Engng., 2002, 41(11): 2899~2902

    [8] F. Lei, L. K. Dang. Measurement of the numerical aperture and F-number of a lens system by using a phase grating[J]. Appl. Opt., 1993, 32(28): 5689~5691

    [9] Brian J. DeBoo, Jose M. Sasian. Novel method for precise focal length measurement[C]. International Optical Design Conference, 2002, 114~121

    [10] F. Lei, L. K. Dang. Measuring of the focal length of optical system by grating shearing interferometry[J]. Appl. Opt., 1994, 33(28): 6603~6608

    [11] Zhang Peng, Cao Xuedong, Wu Shibin et al.. The application of image processing technology for the measurement of micro-lens array focus[J]. Electronic Instrumentation Customer, 2008, (5): 15~16

    [12] Zhang Yuhong, Liu Baoyuan. Testing of optical preparation of microlens array[J]. Science and Technology of West China, 2008, 27(7): 14~16

    [13] Shuai Zhao, Jacky Fung Wen, Po Sheun Chung. Simple focal-length measurement technique with a circular dammann grating[J]. Appl. Opt., 2007, 46(1): 44~49

    [14] Jiao Guohua, Li Yulin, Hu Baowen. Measurement of microlens array surface by mirau phase changed interferometer[J]. Acta Photonica Sinica, 2007, 36(10): 1924~1927

    [15] Daniel R. Neal, James Copland, David A. Neal et al.. Measurement of lens focal length using multi-curvature analysis of Shack-Hartmann wavefront data[C]. SPIE, 2004, 5523: 243~255

    [16] Yeddanapudi Pavan Kumar, Sanjib Chatterjee. Technique for the focal-length measurement of positive lenses using Fizeau interferometry[J]. Appl. Opt., 2009, 48(4): 730~736

    [17] Alma A. Camacho, P. Cristina Solano, Moises Cywiak et al.. Method for the determination of the focal length of a microlens[J]. Opt. Engng., 2000, 39(8): 2149~2152

    [18] Arun Anand, Vani K. Chhaniwal. Measurement of parameter of simple lenses using digital holographic interferometry and a synthetic reference wave[J]. Appl. Opt., 2007, 46(11): 2022~2026

    [19] Hou Changlun, Bai Jian, Hou Xiyun. The measurement of long focal length based on talbot effect of ronchi grating[J]. Acta Optica Sinica, 2002, 22(11): 1328~1330

    [20] Zhu Xianchang, Cao Xuedong, Wu Shibin et al.. Focal length measurement of microlens by rotation method based on grating multiply diffraction[J]. Acta Optica Sinica, 2011, 31(5): 0523001

    [21] Liang Quanting. Physical Optics [M]. Beijing: China Machine Press,1980. 136~137

    [22] Zheng Guangwei, Liu Li, He Yanlan. Diffraction properties of ultra-short pulsed Gaussian laser beam by transmission volume grating[J]. Acta Optica Sinica, 2008, 29(1): 126~131

    [23] Zhang Weiguo, Dong Xiaochun, Gao Hongtao et al.. Disturbance induced by diffraction effects of microlens array[J]. Opto-Electronic Engineering, 2010, 37(5): 80~84

    CLP Journals

    [1] Li Dan, Xue Yunyun, Cao Wen, Yao Lianfang, Shi Huishuang, Kwok Hoising, Zhang Baolong. Optimization of DMD Illumination System with Microlens Array[J]. Acta Optica Sinica, 2013, 33(1): 122002

    Zhu Xianchang, Wu Fan, Cao Xuedong, Wu Shibin, Zhang Peng. Analysis of Focus Dislocation Induced by the Microlens Array Measuring Based on Grating Diffraction[J]. Acta Optica Sinica, 2011, 31(11): 1112010
    Download Citation